EEWORLDEEWORLDEEWORLD

Part Number

Search

DF12.ABDWF150C0.3310.1

Description
Mains Power Connector, 3A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

DF12.ABDWF150C0.3310.1 Overview

Mains Power Connector, 3A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

DF12.ABDWF150C0.3310.1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings3A, 250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Power Entry Modules with Line Filter
www.schurter.com/pg06
IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45 (recessed)
DF2
Medical version
C14
70° C
- Panel Mount:
Screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter DF11
- Substitute for type 5145
- Alternative: Standard version DF12
Description
Characteristics
- All single elements are already wired
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage- or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Unwired versions
- Line switch 1-pole
- Other rocker marking
- Medical version M80
- Capacitance CX1
Approvals
- VDE License Number: 40012935
- UL License Number: E72928
References
Weblinks
General Product Information
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
IEC 60939, IEC 60601-1, UL 1283, UL
544, EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit Breakers
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC Products

Clock Constraint Problems of DC Integrated Frequency Division Circuit
The main clock is CLKA, which is 64M. Now we need to divide it by 4 and 8 to generate CLKB and CLKC as the clocks of other modules. How should we constrain CLKB and CLKC? create_generated_clock -name ...
eeleader FPGA/CPLD
Please send me your manuscripts, the more the better (Publishing)
If you have any manuscripts, please send them to me. The more the better. (Publishing) Our company is a well-known IT book planning and publishing company in the industry. We have many years of book p...
634749 Recruitment
Compare 11a, 11b, 11g and 11n to provide the differences between 11a, 11b, 11g and 11n, 802.11 standards
Compare 11a, 11b, 11g and 11n to provide the differences between 11a, 11b, 11g and 11n, 802.11 standards.802.11a Modulation scheme OFDM Data rates 6, 9, 12, 18, 24, 36, 48, 54 Mbps RF carrier 5GHz Ban...
兰博 RF/Wirelessly
How to identify USB mobile media and USB optical drive or USB hard disk in USB protocol?
In a U3 disk, the USB disk can be recognized by the Windows system as an optical drive, a mobile storage medium, or a local hard disk. I want to know how this is achieved? In the USB protocol, which p...
gobbs Embedded System
Op amp basics: DC biasing of active circuits
In this lab, we introduce an active circuit, the operational amplifier, which has certain properties (high input resistance, low output resistance, and large differential gain) that make it a nearly i...
Jacktang Analogue and Mixed Signal
Two-way car alarm design.rar
[i=s]This post was last edited by paulhyde on 2014-9-15 09:47[/i] Graduation Project 3 - Two-way Car Alarm Design.rar...
dtcxn Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 738  1681  398  1837  2000  15  34  9  37  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号