P A I R E D
C A B L E S
5.46
Combination Shields
Special Audio, Communication and Instrumentation Cables
Description
Part
No.
UL NEC/
C(UL) CEC
Type
No.
of
Pairs
Color
Code
Standard Lengths
Ft.
m
Standard
Unit Weight
Lbs.
kg
Insulation
Thickness
Jacket
Thickness
Nominal
OD
Nominal Capacitance
*
pF/
Ft.
*
pF/
m
**
pF/
Ft.
**
pF/
m
Inch mm Inch mm Inch mm
25 AWG
Stranded Conductors (7x33) • Tinned Copper • Overall 100% Beldfoil
®
Shield Coverage • 25 AWG Stranded TC Drain Wire
Polyethylene Insulation • Chrome PVC Jacket
(Pairs Cabled on Common Axis to Reduce Diameter)
400V 80ºC
8434
2
Red & Black
100
500
Unshielded:
U-1000
Green &
1000
White
Shielded:
30.5 2.1
152.4 7.0
U-304.8 13.0
304.8 14.0
1.0 .013
3.2
5.9
6.4
.33
.020
.51
.165 4.19
25
82
40
131
Shorting Fold
Red/Black pair 100% Beldfoil shielded with drain wire.
3 copper, 4 copper-covered steel strands in each conductor.
22 AWG
Stranded Conductors (7x30) • Tinned Copper • One Pair 100% Beldfoil Shielded • Stranded Tinned Copper Drain Wire
PVC Insulation • Chrome PVC Jacket
(Pair and Single Cabled)
300V RMS 90ºC
9685
NEC:
1.5
Shielded:
U-1000 U-304.8 24.0
CM
(1 pair +
1 single)
10.9 .013
.33
.032
.81
.199 5.05
60
197
99
325
Black &
White
Unshielded:
Brown
Meets NEC Article 800
22 AWG drain wire
Polypropylene Insulation • Chrome PVC Jacket
(Pairs Cabled on Common Axis to Reduce Diameter)
200V 80ºC
8730
†
2
Shielded:
U-1000 U-304.8 25.0 11.4 .008 .20 .030 .76 .205 5.21
Red &
Black
Unshielded:
24 AWG drain wire
34
111
67
220
1000
304.8 25.0
11.4
Green &
White
300V 80ºC
VW-1
8724
†
NEC:
CM
CEC:
CM
2
Shielded:
Red &
Black
Unshielded:
U-1000
1000
U-304.8 21.0
304.8 21.0
9.5 .008
9.5
.20
.019
.48
.165 4.19
34
112
67
220
Green &
White
24 AWG drain wire
22 AWG
Stranded Conductors (7x30) • Tinned Copper • Cabled in Pairs • Overall 100% Beldfoil Shield • 24 AWG Stranded TC Drain Wires
Polypropylene Insulation • Chrome PVC Jacket
(Pairs Cabled on Common Axis to Reduce Diameter)
UL AWM Style 2717
(80°C)
8728
NEC:
CM
CEC:
CM
2
Black &
U-500
Red
500
Green & U-1000
White
1000
U-152.4
152.4
U-304.8
304.8
15.0
15.5
30.0
30.0
6.8 .010
7.0
13.6
13.6
.25
.028
.71
.215 5.46
35
115
62
203
Meets NEC Article 800
Each pair Beldfoil shielded with individual drain wire plus polyester film over each shield.
TC = Tinned Copper
*Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
†
Request Technical Bulletin T/8-21 before planning high and low level circuits in the same cable.
B e l d e n E l e c t r o n i c s D i v i s i o n
Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
o r
1 - 8 0 0 - B E L D E N - 3
•
w w w . b e l d e n . c o m