EEWORLDEEWORLDEEWORLD

Part Number

Search

BWS0505-81V

Description
DC-DC Regulated Power Supply Module, 1 Output, 2.5W, Hybrid, DIP-10
CategoryPower/power management    The power supply circuit   
File Size489KB,3 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

BWS0505-81V Overview

DC-DC Regulated Power Supply Module, 1 Output, 2.5W, Hybrid, DIP-10

BWS0505-81V Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
Parts packaging codeDFM
package instruction,
Contacts10
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage9 V
Minimum input voltage4.5 V
Nominal input voltage5 V
JESD-30 codeR-XDMA-P10
JESD-609 codee0
Number of functions1
Output times1
Number of terminals10
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
Maximum output voltage5.25 V
Minimum output voltage4.75 V
Nominal output voltage5 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output2.5 W
Fine-tuning/adjustable outputNO
Powering Communications and Technology
BWS SERIES
2.5 WATT
DESCRIPTION
BWS DC/DC converters offer excellent regulation
and isolation in an industry standard DIP package.
The BWS is ideal for industrial, telecom, and
networking applications, and features short circuit
protection, low profile, and 500 VDC isolation. Please
see the BWD series for dual output applications.
FEATURES
• Industry Standard DIP
Package
• Industry Standard Pinout
• 85°C Case Operation
• Short Circuit Protection
TECHNICAL SPECIFICATIONS
General
4.5 - 9 VDC
9 - 18 VDC
20% I
in
Max.
100% I
in
Max.
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Isolation Resistance - Input to Output
Isolation Capacitance - Input to Output
No Load Input Power
Case Temperature
Standard Operating Range
Industrial Range (Add -I to p/n)
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Safety
Weight (approx.)
200 kHz
500 VDC
500 VDC
500 VDC
109 Ohms
80 pF
0.70 W
-25 to +85°C
-40 to +85°C
-40 to +125°C
95%
5 g, 10 - 55 Hz
UL, cUL, TUV
0.6 oz
Wide Range Inputs
Input Pi Filter
Regulated Outputs
500V Isolation
Input
Voltage Range
5 VDC Nominal
12 VDC Nominal
Reflected Ripple
Reverse Input Current
Output
Setpoint Accuracy
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Temperature Coefficient
Ripple And Noise, 20 MHz BW
Short Circuit Protection 1
Current Limit
±5%
±1.5% V
out
±2.5% V
out
10% I
out
Rated
25% I
out
1% V
out
500
µs
0.02%/°C
150 mV
Continuous
180%
Notes
1 Continuous short circuit protection is provided. Long-term continuous operation in
this mode is not recommended. Converter will auto-restart once fault has been
removed.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260
°
C, ten seconds; fully compatible with commercial
wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
1
Analysis of Classic Op Amp Circuits
...
wingard Analog electronics
Has anyone worked with the MPU5060 sensor?
Is there a program for MSP430F5529 to drive the MPU6050 angle sensor?...
HI唐辉 Electronics Design Contest
How to read the other party's telephone key value through MODEM
I checked some information and it said that it must be voice mode (AT+FCLASS=8). Use AT+VLS=1 to answer and then enter the key value (such as the # key). It is displayed as / key value (#) ~ I tried i...
dfx168 Embedded System
Transfer of unused Fluke multimeter
[i=s]This post was last edited by wsmysyn on 2018-4-27 21:00[/i] RT I have an extra Fluke multimeter on hand; the model is Fluke F15B+ :lol I got it on a certain website, and it was shipped directly b...
wsmysyn Talking
Is the show after vxworks starts not grand enough?
Why does the wxworks5.5 I just configured with wmware not display the large VxWorks welcome interface after successfully starting, but only a few ordinary lines of text?...
pcwe Real-time operating system RTOS
Transformer Winding Problems
The company has never had transformer winding equipment. Every time we make power supplies, we have to find an external factory to make transformers. Sometimes, even a small adjustment to the transfor...
czf0408 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1410  2882  1312  64  2719  29  59  27  2  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号