EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MF.03A.05.10.GC

Description
Mains Power Connector, 3A, 250VAC, Male, Solder Terminal
CategoryThe connector    The connector   
File Size718KB,3 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F.MF.03A.05.10.GC Overview

Mains Power Connector, 3A, 250VAC, Male, Solder Terminal

F.MF.03A.05.10.GC Parametric

Parameter NameAttribute value
MakerKEMET
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320, CSA, UL, VDE
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSCREW
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 250VAC
Manufacturer's serial numberF.MF
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Voltage selector
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
Approvals
29
[Design Tools] Xilinx Spartan-6 LX9 MicroBoard startup operation diagram
The low-cost Spartan-6 LX9 MicroBoard is a great solution for engineers who are focused on Microblaze embedded applications and Spartan-6 devices. This kit provides several pre-built Microblaze embedd...
GONGHCU FPGA/CPLD
[NXP Rapid IoT Review] 3 - BLE Bluetooth Data Transmission Experiment
The original application was to collect accelerometer data in real time through wireless communication and monitor the operation status of the device. Therefore, wireless transmission function is requ...
jf8loo RF/Wirelessly
STM32F10x RS485 Modbus RTU Slave Source Program
STM32F10x RS485 modbus RTU slave source codeSupports all RS485 modbus RTU slave commands;reads 4DI and 1 AI of the development board through RS485 modbus protocol;controls 3DO and 1 AO of the developm...
eewzml stm32/stm8
Relationship between Spaceborne SAR Performance and TR Component Inconsistency
Abstract: This paper analyzes the impact of TR component amplitude and phase inconsistency on the performance of spaceborne SAR radar system. TR component inconsistency has a certain impact on the sid...
JasonYoo Embedded System
Summary of the advantages of MSP430 with ferroelectric memory
1. With RTC clock. 2. Improved read and write speed. Lower power consumption. 3. FRAM can store other data. 4. With multiplier, faster speed. 5. Lowest overall power consumption. Save investment in po...
iwqtthf Microcontroller MCU
Ask for advice on data communication issues
My system uses the front-end FPGA to cache data, and the parallel port transfers it to ARM (lpc2214) for packaging, and then to the network controller (lan9115) to send it to the pc. The three chips s...
yuyijun Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 81  1349  661  1966  1008  2  28  14  40  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号