EEWORLDEEWORLDEEWORLD

Part Number

Search

2026-30C2

Description
Surge Protection Circuit,
CategoryWireless rf/communication    Telecom circuit   
File Size536KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2026-30C2 Overview

Surge Protection Circuit,

2026-30C2 Parametric

Parameter NameAttribute value
package instruction,
Reach Compliance Codeunknow
JESD-30 codeO-XXSS-P3
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeROUND
Package formSPECIAL SHAPE
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Base Number Matches1
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced TRIGARD
®
Approximately 8 mm diameter, 11 mm long
UL recognized
Custom configurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Model No.
2026-20
200 V
425 V
625 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2026-07
75 V
275 V
700 V
2026-09
90 V
275 V
600 V
2026-15
150 V
350 V
575 V
2026-23
230 V
450 V
650 V
2026-25
250 V
475 V
700 V
2026-26
260V
1
475 V
700 V
2026-30
300 V
500 V
775 V
2026-35
350 V
625 V
875 V
Model No.
2026-40
2026-42
400 V
420 V
675 V
925 V
725 V
1000 V
2026-47
470 V
800 V
1100 V
2026-60
600 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
10
Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
2
.................................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 µs
3
.................................................... 1 operation minimum
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ................................................... 1 operation
1000 A, 10/1000 µs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles
3
............................................... 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
®
Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω
(-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1
2
3
Tube meets BT requirement Type 14 A/1 (210-310 V).
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
MSP430 communication resources IIC communication
1. I I C DescriptionThe above figure shows that there should be at least one microcontroller in the IIC bus topology. The controller communicates with other associated devices through the SCL and SDA ...
Jacktang Microcontroller MCU
【Design Tools】Fast Startup for Xilinx FPGA
Fast Startup for Xilinx FPGAIn many modern applications, embedded systems must meet extremely demanding timing requirements. One of these is boot time , which is the time it takes for an electronic sy...
sdjntl FPGA/CPLD
[Video] SensorTile Bluetooth Remote Control Gunfire
This remote control firecracker modified from SensorTile is very convenient to use, especially for people like me who don’t have a lighter in my pocket. The problem now is that the heating wire in the...
littleshrimp MEMS sensors
I'm posting this thread to find out what boards and cards you guys have come across recently and that you would like to play with or are worth playing with in the next year?
As the title says, I just want to buy condoms. Netizens in the forum, have you found any new products worth trying recently? Can be existing or expected to be released It can be analog, sensor, MCU, w...
nmg Special Edition for Assessment Centres
What are the application areas where FPGA has the greatest advantages?
[align=center][/align] When working in electronics, I am often asked if I have worked on FPGA. This thing is really amazing, and it is completely different from the previous single-chip microcomputer....
高进 Talking
[Zero-knowledge ESP8266 tutorial] Quick Start 5-Use buttons to control your lights
In the last lesson, we have learned how to make a simple traffic light, so how to control the on or off of an LED? This experiment uses a button to control our LED to achieve simple control of the LED...
roc2 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2490  1237  231  2920  1520  51  25  5  59  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号