EEWORLDEEWORLDEEWORLD

Part Number

Search

L020C24I

Description
Power Transformer, 20VA
CategoryPower management    transformer   
File Size108KB,1 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Download Datasheet Parametric View All

L020C24I Overview

Power Transformer, 20VA

L020C24I Parametric

Parameter NameAttribute value
MakerCrydom
Reach Compliance Codeunknown
ECCN codeEAR99
Center click function 1NO
Center click function 2NO
high52 mm
Insulation voltage3000 V
length59 mm
Manufacturer's serial numberL020C24I
Installation featuresCHASSIS MOUNT
Number of secondary windings1
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
Output voltage 124 V
physical size59mm X 50mm X 52mm
main ratingDUAL 115/230V
surface mountNO
Transformer typePOWER TRANSFORMER
VA rating20 VA
width50 mm
10
Chassis Transformers
E F
A
B
Power
(VA)
3
6
12
20
30
40
50
Mass
(kg)
0.17
0.23
0.31
0.53
0.64
0.68
1
Regulation
(%)
20
20
20
15
20
15
10
A
(mm)
45
50
56
59
70
70
78
B*
(mm)
54
60
68
73
83
83
92
C
(mm)
16
18
20
28
24
34
27
C
D
D
(mm)
35
38
41
52
51
60
56
E
(mm)
23
25
28
31
36
36
41
F
(mm)
37
41
47
50
56
56
65
• Input voltages,
single 230V or dual
115V/230V
50/60Hz
• Reinforced isolation -
tested at 3kVrms
• Transformers dip
coated in varnish as
standard
• Solder tag
terminations
• Operational ambient
temperature range
-20°C to +50°C
*Recommended fixing centres
Part Numbering System
Example
- L 003 C 15
I
Output Power
003 = 3VA
006 = 6VA
012 = 12VA
020 = 20VA
030 = 30VA
040 = 40VA
050 = 50VA
Style
C = chassis
Voltage Output
06 = 2x6V
09 = 2x9V
12 = 2x12V
15 = 2x15V
18 = 2x18V
20 = 2x20V
24 = 2x24V
Finish Options
T = Thermal cutout*
L = Flying leads*
I = Vacuum impregnation
E = Additional Enveloping*
S = Single 230V Input
Example L003C15I = Chassis mounted 115V/230V input, 2x15V output, 3VA transformer
with vacuum impregnated varnish finish and solder tag termination.
* Available for certain sizes - please call for details.
cha
ssis
transfor
mers
CONTACT US NOW
UNITED KINGDOM
CRYDOM
T
+44 (0) 1202 897969
F
+44 (0) 1202 891918
E
magnetics@crydom.com
W
www.crydom.co.uk
How to use ulink2 keil
How can I use ulink to download the compiled Steploader and EBOOT to the board? Is the PC software using keil uvision 3? ? Can ulink2 + ads be used?...
zhangyoufu Embedded System
Design of Embedded Web Server Based on TMS320DM642
[size=5]Design of Embedded Web Server Based on TMS320DM642[/size] [size=5][/size] [size=5] [/size] [size=5][/size]...
Jacktang DSP and ARM Processors
Dear experts, I would like to ask how to add excitation to the HMC1043 geomagnetic sensor. Thank you.
Dear experts, I would like to ask how to add excitation to the HMC1043 geomagnetic sensor. Thank you....
JERRR Analog electronics
The DSL chips of the two boards handshake successfully through the ATM interface, but the ping fails.
What could be the reason for this? If you need any more information, please feel free to ask!...
chenls Embedded System
ucos ii interrupt task problem
I'm doing some ucos porting recently, but I use multiple interrupts to receive and send. In the system's interrupt management, I can nest interrupts, but in the task, I interrupt to receive data and t...
zouweihua Real-time operating system RTOS
Everyone please help me!!!
I want this circuit to have high current and high frequency. Is there any way? The limit is +-10...
sjhhhy Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1662  1074  4  1574  1794  34  22  1  32  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号