General Purpose Fuses IEC
General Purpose Fuses IEC
Ferrule Fuses
aM & gG 400V to 690V
with/without Striker
aM & gG 8x32, 10x38, 14x51, 22x58
Residential and Industrial
Cylindrical Fuse-links
Ferraz Shawmut gF/gG-gG and aM fuse-links cover
a wide range of physical sizes and ampere ratings
for 250, 380*/ 400, 500, and 660* 690volts AC.
gF/gG fuse-links are for residential use. gG and aM
fuse-links are for industrial applications. Most
ratings are available with an optional indicator. All
industrial fuse-links have the option of a built-in
striker. All cylindrical fuse-links have ceramic bodies
and silver-plated ferrules.
* Fuse-links marked 380V (gF/gG) and 660V (gG-aM) will be
re-marked (and safely used at ) 400V AC and 690V AC in
compliance with changes in IEC Standard 269, but should
not be used above 418V AC or 726V AC.
gF/gG
Residential
Full Range
Protection
•
7 physical sizes
from 6.3 x 23mm
to 10.3 x 38 mm
•
250 and 380 Volt
ratings - 0.5A
thro
ug
h 32A
gG
Full Range
Protection
•
4 physical sizes
from 8 x 31mm
to 22 x 58 mm
•
400, 500 and 690
Volt ratings -0.5A
through 125A
gG
Full Range
Protection
Fuse-links
with striker
aM
aM
Short Circuit Short Circuit
Protection
Protection
• 4 physical sizes
from 8 x 31 mm
to 22 x 58 mm
Fuse-links
with striker
•
2 sizes -
14 x 51mm and
22 x 58mm
•
400, 500 and
690 Volt ratings
- 2A through
125A
•
All ratings
include striker
•
Meet IEC, NFC
and UNE
standards
•
Approved by
Lloyds Register
of Shipping and
Bureau Veritas
•
2 sizes-
14 x 51mm
•
400, 500 and
and 22 x 58 mm
690 Volt ratings-
0.16A through
•
400, 500 and
125A
690 Volt ratings
4A through 125A
•
All ratings
include striker
•
Meet IEC,
NFC and UNE
standards
•
Approved by
Lloyds Register of
Shipping and
Bureau Veritas
•
Most ratings
available with
indicator
•
Meet IEC, NFC,
UNE standards
•
See residential
fuse-links, Special
Purpose section
•
Most ratings
available with
indicator
•
Most ratings
available with
indicator
•
Meet IEC, NFC
and UNE
standards
•
Approved by
Lloyds Register
of Shipping and
Bureau Veritas
•
Meet IEC, NFC
and UNE
standards
•
Approved by
Lloyds Register
of Shipping and
Bureau Veritas
GPEU
2
General Purpose Fuses IEC
General Purpose Fuses IEC
Ferrule Fuses
aM 400V to 690V
with/without Striker
aM 8x32, 10x38, 14x51, 22x58
Ratings – aM (Optional Blown-Fuse Indicator)
Size
Rated In
Rated
(mm x mm) Current (A)
1
S219229
8 x 31
2
4
6
8
10
0.16
0.25
0.5
1
2
4
6
8
10
12
16
20
25
32
0.25
0.5
1
2
4
6
8
10
12
16
20
25
32
40
45
50
1
2
4
6
8
10
12
16
20
25
32
40
50
63
80
100
125
Previous Reference
Reference Number
w
w/o
w
Voltage
w/o
Indicator Indicator Indicator Indicator
15511
-
C217168
-
15513
-
R218193
-
15519
-
S219229
-
400V
15523
-
C222205
-
15527
-
F200749
-
15531
-
W201292
-
16503
-
E214617
-
16507
-
M215130
-
16509
-
W216150
-
16511
16711
F217171
X219233
16513
16713
H218714
G222209
16519
16719
W219232
K200753
16523
16723
F222208
K201811
500V
16527
16727
Z201295
Z211553
16531
16731
Y211552
H213102
16533
16733
A213601
D214110
16535
16735
F214618
P215132
16537
16737
X216151
V216655
400V
16539
16739
G217172
L217682
400V
16543
-
J218715
-
17507
-
B212590
-
17509
-
L213105
-
17511
17711
E213605
C212591
17513
17713
H214114
M213106
17519
17719
K214622
J214115
17523
17723
S215135
T215136
17527
17727
T215642
A216660
17531
17731
Z216659
R217687
690V
17533
17733
M217177
Q218721
17535
17735
Q217686
F219770
17537
17737
P218720
R200759
17539
17739
E219769
Q201816
17543
17743
M222214
F211559
500V
17547
17747
Q200758
D212592
17549
17749
L211035
G213607
400V
17551
17751
E211558
M214624
18511
-
M219776
-
18513
-
T222220
-
18519
18719
Q222976
L219246
18523
18723
Y200765
V222221
18527
18727
N201308
Y201823
18531
18731
X201822
N211566
18533
18731
T211042
K212598
18535
18735
M211565
P213614
690V
18537
18737
S212076
V214631
18539
18739
J212597
D215651
18543
18743
V213113
J216668
18547
18747
N213613
Z217694
18551
18751
R214122
P219778
18555
18755
C215650
Z200766
18559
18759
H216667
P211567
500V
18563
18763
Y217693
L212599
400V
18565
18765
J218209
W214632
Breaking
Capacity
Catalog Number
w/o
w
Indicator
Indicator
FR8AM40V1
FR8AM40V2
FR8AM40V4
FR8AM40V6
FR8AM40V8
FR8AM40V10
FR10AM50V0.16
FR10AM50V0.25
FR10AM50V0.5
FR10AM50V1
FR10AM50V1I
FR10AM50V2
FR10AM50V2I
FR10AM50V4
FR10AM50V4I
FR10AM50V6
FR10AM50V6I
FR10AM50V10 FR10AM50V10I
FR10AM50V10 FR10AM50V10I
FR10AM50V12 FR10AM50V12I
FR10AM50V16 FR10AM50V16I
FR10AM50V20 FR10AM50V20I
FR10AM50V25 FR10AM50V25I
FR10AM50V32
FR14AM69V0.25
FR14AM69V0.5
FR14AM69V1
FR14AM69V1I
FR14AM69V2
FR14AM69V2I
FR14AM69V4
FR14AM69V4I
FR14AM69V6
FR14AM69V6I
FR14AM69V8
FR14AM69V8I
FR14AM69V10 FR14AM69V10I
FR14AM69V12 FR14AM69V12I
FR14AM69V16 FR14AM69V16I
FR14AM69V20 FR14AM69V20I
FR14AM69V25 FR14AM69V25I
FR14AM69V32 FR14AM69V32I
FR14AM69V40 FR14AM69V40I
FR14AM69V45 FR14AM69V45I
FR14AM69V50 FR14AM69V50I
FR22AM69V1
FR22AM69V2
FR22AM69V4 FR22AM69V4I
FR22AM69V6 FR22AM69V6I
FR22AM69V8 FR22AM69V8I
FR22AM69V10 FR22AM69V10I
FR22AM69V12 FR22AM69V12I
FR22AM69V16 FR22AM69V16I
FR22AM69V20 FR22AM69V20I
FR22AM69V25 FR22AM69V25I
FR22AM69V32 FR22AM69V32I
FR22AM69V40 FR22AM69V40I
FR22AM69V50 FR22AM69V50I
FR22AM69V63 FR22AM69V63I
FR22AM69V80 FR22AM69V80I
FR22AM69V100 FR22AM69V100I
FR22AM69V125 FR22AM69V125I
20kA - 400V
F214618
10 X 38
120kA - 500V
120kA - 400V
120kA - 400V
Q217686
14 X 51
80kA - 690V
120kA - 500V
120kA - 400V
C215650
22 x 58
80kA - 690V
Packaging 10
120kA - 500V
120kA - 400V
Blown-Fuse Indicator
Dimensions
FUSE SIZE
A
B
C
BEFORE
AFTER
8 x 31
10 x 38
14 x 51
22 x 58
GPEC
8
8.5
10.3
14.3
22.2
31.5
38
51
58
6.3
10.5
13.8
16.2
General Purpose Fuses IEC
General Purpose Fuses IEC
Ferrule Fuses
aM 400V to 690V
with/without Striker
aM 8x32, 10x38, 14x51, 22x58
Ratings – aM with Striker
Size
Rated
(mm x mm) Current In
(A)
1
2
4
6
8
10
12
16
20
25
32
40
45
50
1
2
4
6
8
10
12
16
20
25
32
40
50
63
80
100
125
Rated Previous Reference
Voltage Reference Number
17911
17913
17919
17923
17927
17931
17933
17935
17937
17939
17943
17947
17949
17951
18911
18913
18919
18923
18927
18931
18933
18935
18937
18939
18943
18947
18951
18955
18959
18963
18965
Breaking
Capacity
Catalog
Number.
FR14AM69V1P
FR14AM69V2P
FR14AM69V4P
FR14AM69V6P
FR14AM69V8P
FR14AM69V10P
FR14AM69V12P
FR14AM69V16P
FR14AM69V20P
FR14AM69V25P
FR14AM69V32P
FR14AM69V40P
FR14AM69V45P
FR14AM69V50P
FR22AM69V1P
FR22AM69V2P
FR22AM69V4P
FR22AM69V6P
FR22AM69V8P
FR22AM69V10P
FR22AM69V12P
FR22AM69V16P
FR22AM69V20P
FR22AM69V25P
FR22AM69V32P
FR22AM69V40P
FR22AM69V50P
FR22AM69V63P
FR22AM69V80P
FR22AM69V100P
FR22AM69V125P
X215645
14 X 51
500V
400V
K216669
22 X 58
690V
500V
400V
W215644
B216661
C218203
E219240
N222215
S200760
R201817 120kA 500V
G211560
E212593
H213608
N214625
X215645
C216662
D218204 120kA - 400V
E215652
J216162
A217695
Y218728
Q219779
S222978
R201311
W211044
W212079 80kA - 690V
Q213615
X214633
F215653
K216669
B217696
Z218729 120kA - 500V
T222979
S201312 120kA - 400V
Packaging 10
Dimensions
Fuse Size
A
B
C
D
E
Striker
51
58
13.8
16.2
7.5
7.5
3.8
3.8
BEFORE
AFTER
14 x 51
22 x 58
14.3
22.2
Neutral
Size
Previous Reference Standard
(mm x mm) Reference Number Pack/CTN
Catalog
Number
10 x 38
14 x 51
22 x 58
19100
19200
19300
R211569
M212600
R213616
10
FRN1038
FRN1451
FRN2258
GPEU
9
General Purpose Fuses IEC
General Purpose Fuses IEC
Ferrule Fuses
aM 400V to 690V
with/without Striker
aM 8x32, 10x38, 14x51, 22x58
Characteristics t-l
aM
PREARCING TIME T(S)
PROSPECTIVE CURRENT (A rms)
Cut-off characteristics
MAXIMUM VALUE OF CURRENT (KA PEAK)
PROSPECTIVE CURRENT (kA rms)
GPEU
10
General Purpose Fuses IEC
General Purpose Fuses IEC
Ferrule Fuses
gG 400V to 690V
with/without Striker
aM 8x32, 10x38, 14x51, 22x58
Characteristics I2t
I
2
T VALUE (A
2
S)
aM
690 V
500 V
400 V
}
{
- OPERATING I2T
- PREARCING I2T
RATED CURRENT (A)
Temperature increase table (testing in superior contact)
ºC
80
70
60
50
40
30
20
10
1 2 4
6 8 10 12 16 20 25 32
1 2 4
6 8 10 12 16 20 25 32 40 50
1 2 4
6 8 10 12 16 20 25 32 40 50 63 80 100 125
In
10 x 38
14 x 51
22 x 58
GPEU
11