PRL0602NF-18

Description
AC-DC Active PFC SWITCHING POWER SUPPLY
File Size450KB,5 Pages
ManufacturerULTRA LEVEL TECH CO., LTD.
Websitehttp://www.ultralevel.com.tw/
Download Datasheet Compare View All

PRL0602NF-18 Overview

AC-DC Active PFC SWITCHING POWER SUPPLY

ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw
Tel:+886-2-29180118
Fax:+886-2-29181465
We Supply the Power Customers Need
ISO9001
220W ~ 400W AC-DC Active PFC SWITCHING POWER SUPPLY
PRL0602N SINGLE OUTPUT SERIES
FEATURES:
Compact 400W with 1U height Power Density: 11.11 watts/cu in
Active Power Factor Corrected to EN61000-3-2 Class D
Built-in Remote On-Off, Power Good, Fan Fail Alarm
Peak Power 700W within 500uS Duty Duration
Variable Fan Speed & Low Acoustical Noise
High Quality & Reliable Component Usage
Output Voltage ranging from 12 ~ 60Vdc
4 - Mechanical Options
Full Range AC Input
U Type:
6(L) x 4(W) x 1.5(H)”
E Type:
7(L) x 4(W) x 1.6(H)”
F Type:
6(L) x 4(W) x 2(H)”
C Type:
6(L) x 4(W) x 1.57(H)”
PRODUCT SPECIFICATIONS:
Input Voltage:
90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current:
8A at 90Vac full load.
Inrush Current:
Max. 70A@230Vac & 35A@115Vac; both under
cold start conditions.
Power Factor Correction: >0.9
@ Vin: 230Vac full load.
Transient Response:
Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot:
Turn-on & off overshoot < 5% over nominal voltage.
Efficiency:
75minimum (Measuring at 230V and full load).
Turn On Delay:
1.5 second maximum at 120 Vac.
Hold Up Time:
16mS min. at 75% of full load at 120Vac.
Adjustability:
Output user adjustable +/-5% minimum.
Fan Drive:
12VDC/300mA offering to drive an external fan.
Fan Fail (FF) Alarm:
Designated as
FF
on pin 3 of CN1, two types
of logical signal provided, contact manufacturer.
Remote On-Off:
Designated as
INH
on pin4 of CN1, requires a low
signal to inhibit output.
Power Supply On:
Green LED designated as
LED1
on the PCB.
Power Good:
Designated as
PG
on CN1 and TTL high 100-500mS
after DC regulation. It goes low at least 1mS before loss of regulation.
Input Fusing Protection:
One T8A/250V fuse inserted in primary.
Over-Power Protection:
110~140% of I-Max; Auto-recovery.
Short Circuit Protection:
Trip without damage and auto-recovery.
Over Voltage Protection:
Unit latching down when output exceed
130% and recycle AC input to reset.
Over-Temperature Protection:
Unit protected of excessive
operating ambient 110
℃±5 ℃,
and automatic recovery.
Operating Temperature:
0℃ to 70℃ ambient, de-rating at 2.5% per
degree from 50℃ to 70℃.
Warranty:
2 years.
Switching Frequency:
68kHz PFC, 55 kHz PWM
CB
Vibration:
5 ~ 50 Hz, acceleration
±7.35
m/s*s on X,Y and Z Axis.
Storage Temperature:
-20℃ to 85℃.
Operating Humidity:
5% to 90% RH, Non-condensing.
Storage Humidity:
5% to 95% RH, Non-condensing.
EMC:
EN55022 class B conducted / radiated, EN61000-3-2,
EN61000-3-3; EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-
4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-11).
Safety Regulation:
UL1950, CSA C22.2 No. 950-95, EN60950
and CB certificate
Leakage Current:
< 3.5mA @ 264Vac.
(optional for 500uA max. at 240Vac / 300uA max. at 120Vac input)
HI-POT Test:
1500 VAC input line to chassis (10mA AC cut off
current); Isolating 3000VAC primary to secondary windings;
Primary to core 1500VAC. All for 3 sec.
Grounding Test:
Apply 25 A from ground pin of the three prong
plug to the far most earth. Max allowable resistance 0.1 ohm.
Warranty:
2 years.
MTBF:
100000 Hrs (according to MIL-HBK-217F) at 30
.
Cooling:
Internal fan is provided.
Enclosure:
U Type: 6(L) x 4(W) x 1.5(H) inches.
C Type: 6(L) x 4(W) x 1.57(H) inches.
E Type: 7(L) x 4(W) x 1.6(H) inches.
F Type: 6(L) x 4(W) x 2(H)inches.
Burn in:
45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight:
Maximum weight is 800g.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.

PRL0602NF-18 Related Products

Description
Portable Iron
Unless you stay at a high-end hotel, the ironing service provided by most hotels is always a headache, which is why many business travelers like to bring their own irons. The portable iron I want to i...
xyh_521 Creative Market
cs8900 network card driver on arm-linux on s3c2410
I have connected a cs8900 to BANK3 of my s3c2410 development board. I use IO mode and interrupt receiving mode. The initialization of relevant registers is as follows: put_reg(PP_RxCFG, get_reg(PP_RxC...
linglidu Linux and Android
Chat Hash Table (Medium)
Last link:https://bbs.eeworld.com.cn/thread-97607-1-1.htmlLast time, we talked about hash functions. It is also called hash function and is an important topic in computer science. What is a hash funct...
richiefang Embedded System
I want to learn about switching power supplies. Can anyone recommend a book?
I want to learn about switching power supplies. Can anyone recommend a book?...
提拉米苏 Power technology
Eye diagram optimization
Does anyone have any insights on the optimization of eye diagrams of high-speed signals? Thank you for your advice....
651076842 Industrial Control Electronics
What are the tools for testing functional performance?
If you don't have enough points, you will get extra points if you have good tools....
xushangjin Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 114  2797  467  2343  2571  3  57  10  48  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号