EEWORLDEEWORLDEEWORLD

Part Number

Search

JCK6048S3V3

Description
DC/DC CONVERTER 60W SINGLE OUTPUT
File Size217KB,2 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Compare View All

JCK6048S3V3 Online Shopping

Suppliers Part Number Price MOQ In stock  
JCK6048S3V3 - - View Buy Now

JCK6048S3V3 Overview

DC/DC CONVERTER 60W SINGLE OUTPUT

DC DC
60 Watts
JCK Series
2:1 Input Range
Very High Power Density
High Efficiency
Remote On/Off
1600 VDC Isolation
OCP, OVP & OTP Functions
3 Year Warranty
Up to 92%
xppower.com
Specification
Input
Input Voltage Range
Input Current
Input Reflected
Ripple Current
Undervoltage Lockout
Input Surge
• 24 V (18-36 VDC),
48 V (36-75 VDC)
• See table
• 20 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
• 24 V models: ON 17.8 V, OFF 16 V typical
48 V models: ON 33.5 V, OFF 30.5 V typical
• 24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
General
Efficiency
Isolation
• See table
• 1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
• 2000 pF typical
• 270 kHz typical
• 37.5 W/in
3
• >110 kHrs min to MIL-HDBK-217F
at 25 ˚C, GB
Isolation Capacitance
Switching Frequency
Power Density
MTBF
Output
Output Voltage
Output Voltage Trim
Minimum Load
Line Regulation
Load Regulation
Setpoint Accuracy
Start Up Time
Ripple & Noise
Transient Response
See table
±10%
No minimum load required
±0.5% max
±0.5% max
±1%
30 ms typical
75 mV for 3V3 +5 V models,
100 mV for other models (see note 2)
• 3% max deviation, recovery to within
1% in <250 µs for a 25% load change
• 0.02%/˚C
Environmental
Operating Temperature
Case Temperature
Cooling
Operating Humidity
Storage Temperature
-40 ˚C to +85 ˚C, see derating curve
+105 ˚C max
Natural convection
5-95% RH, non-condensing
-40 ˚C to +125 ˚C
EMC
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magentic Field
• EN55022 class A conducted & radiated
with no external components
• EN61000-4-2, 4 kV contact discharge,
Perf Criteria B
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 1, Perf Criteria A*
• EN61000-4-5, level 1, Perf Criteria A
• EN61000-4-6, 3 Vrms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
Temperature
Coefficient
Overvoltage Protection
• 3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
Overload Protection
• 115-130% of output current
Short Circuit Protection
• Trip & restart (Hiccup mode),
auto recovery
Remote On/Off
• On = Logic High (>3.0) or Open
Off = Logic Low (<1.2 V) or short pin 2
to 3
*External input capacitor required, 220 µF/100 V.

JCK6048S3V3 Related Products

JCK6048S3V3 JCK6024S3V3 JCK6024S05 JCK6024S12 JCK6024S15 JCK6048S05 JCK6048S12 JCK6048S15
Description DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2220  2377  1091  1158  1392  45  48  22  24  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号