EEWORLDEEWORLDEEWORLD

Part Number

Search

JCK6048S15

Description
DC/DC CONVERTER 60W SINGLE OUTPUT
File Size217KB,2 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Compare View All

JCK6048S15 Online Shopping

Suppliers Part Number Price MOQ In stock  
JCK6048S15 - - View Buy Now

JCK6048S15 Overview

DC/DC CONVERTER 60W SINGLE OUTPUT

DC DC
60 Watts
JCK Series
2:1 Input Range
Very High Power Density
High Efficiency
Remote On/Off
1600 VDC Isolation
OCP, OVP & OTP Functions
3 Year Warranty
Up to 92%
xppower.com
Specification
Input
Input Voltage Range
Input Current
Input Reflected
Ripple Current
Undervoltage Lockout
Input Surge
• 24 V (18-36 VDC),
48 V (36-75 VDC)
• See table
• 20 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
• 24 V models: ON 17.8 V, OFF 16 V typical
48 V models: ON 33.5 V, OFF 30.5 V typical
• 24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
General
Efficiency
Isolation
• See table
• 1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
• 2000 pF typical
• 270 kHz typical
• 37.5 W/in
3
• >110 kHrs min to MIL-HDBK-217F
at 25 ˚C, GB
Isolation Capacitance
Switching Frequency
Power Density
MTBF
Output
Output Voltage
Output Voltage Trim
Minimum Load
Line Regulation
Load Regulation
Setpoint Accuracy
Start Up Time
Ripple & Noise
Transient Response
See table
±10%
No minimum load required
±0.5% max
±0.5% max
±1%
30 ms typical
75 mV for 3V3 +5 V models,
100 mV for other models (see note 2)
• 3% max deviation, recovery to within
1% in <250 µs for a 25% load change
• 0.02%/˚C
Environmental
Operating Temperature
Case Temperature
Cooling
Operating Humidity
Storage Temperature
-40 ˚C to +85 ˚C, see derating curve
+105 ˚C max
Natural convection
5-95% RH, non-condensing
-40 ˚C to +125 ˚C
EMC
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magentic Field
• EN55022 class A conducted & radiated
with no external components
• EN61000-4-2, 4 kV contact discharge,
Perf Criteria B
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 1, Perf Criteria A*
• EN61000-4-5, level 1, Perf Criteria A
• EN61000-4-6, 3 Vrms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
Temperature
Coefficient
Overvoltage Protection
• 3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
Overload Protection
• 115-130% of output current
Short Circuit Protection
• Trip & restart (Hiccup mode),
auto recovery
Remote On/Off
• On = Logic High (>3.0) or Open
Off = Logic Low (<1.2 V) or short pin 2
to 3
*External input capacitor required, 220 µF/100 V.

JCK6048S15 Related Products

JCK6048S15 JCK6024S3V3 JCK6024S05 JCK6024S12 JCK6024S15 JCK6048S3V3 JCK6048S05 JCK6048S12
Description DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT DC/DC CONVERTER 60W SINGLE OUTPUT
Can vxworks compile a dynamic library, that is, can it generate a .so file?
Can vxworks compile a dynamic library, that is, can it generate a .so file? I am using two compilation environments, tornado2.2 and Wind River. Previously, we compiled libraries by writing static libr...
zyjnh005 Real-time operating system RTOS
Strain Gauges
A dynamic force is loaded on one end of the cantilever beam, and a strain gauge is used to measure the strain of the cantilever beam. To ensure that the strain gauge can work normally, what is the max...
a问问 Sensor
Discussion on AC and DC conversion issues
I hope all the power experts will think about the four basic power conversion problems: DC to DC, AC to DC, DC to AC, and AC to AC, including how to convert, what devices or components to use for conv...
piggyfeng Power technology
51 MCU floating point calculation error problem
I would like to ask, after using stc89c52 to do floating point calculations, there is sometimes an error of 0.01 when taking 2 decimal places. What is the accuracy of floating point calculations of si...
zzxuzz 51mcu
MSP430F5529 Power Management Module
Power management and monitoring is a very complex part that is difficult to master. It not only involves the selection of source mode, but also involves complex interrupts and how to handle interrupts...
Jacktang Microcontroller MCU
I want an expert to help me write an intelligent light-controlled street lamp system based on 51 single-chip microcomputer
RT, it would be better if there is a circuit diagram, thanks in advance. . If you have any, please send them to tianya3849@163.com :Cry:...
tianya3849 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 388  2511  1221  890  1013  8  51  25  18  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号