= +40°C nominal input voltage unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
VKA60LS
VKA60MS
Maximum Input Current
VKA60LS
V
IN
= 16VDC
VKA60MS
V
IN
= 27VDC
Reflected Ripple Current
Peak - Peak
Input Ripple Rejection
DC to 1KHz
No Load Input Current LS/MS
Power Dissipation LS/MS
No Load
Standby, Primary On/Off Disabled LS/MS
Inrush Charge
V
IN
= V
IN
max.
VKA60LS
VKA60MS
Quiescent Operating Current
Primary On/Off Disabled
18
33
24
48
36
75
4.4
2.6
VDC
VDC
A
A
mA
dB
mA
W
W
INPUT
50
20
60
50/100
3.6/4.8
0.18/0.4
0.520
0.360
8
12
mC
mC
mA
PARAMETER
OUTPUT
Rated Power
Set point Accuracy
Line Regulation
Load Regulation
Output Temperature Drift
Output Ripple, p-p
Output Current Limit Inception
Output Short-Circuit Current (2)
Output Overvoltage Limit
Transient Response
Peak Deviation
Settling Time
CONDITIONS
MIN
0
TYP
MAX
60
1
0.05
0.05
UNITS
W
%
%
%
%/°C
V
OUT
, Nom
l
OUT
, Nom
l
OUT
, Nom
V
V
OUT
, Nom
µSec
OUTPUT
High Line to Low Line
No Load to Rated Load
DC to 20MHz BW
test
0.02
0.02
±.02
1%
125%
50 to 100% Load Step
di/dt = 1.0A/µSec
V
OUT
, 1% of Nominal Output
2%
100
130%
110%
135%
PARAMETER
ISOLATION
Input to Output
Input to Baseplate
Output to Baseplate
Resistance
Capacitance
Leakage Current
GENERAL
Efficiency, Line, Load, Temp. (3)
Switching Frequency
Remote Sense Compensation
Output Voltage Adjust Range
Remote On/Off Control Inputs
Primary
Sink Current-Logic Low
Vlow
Vhigh
Turn-on Time
Weight
TEMPERATURE
Operation/Specification
Storage
Shutdown Temperature
Thermal Impedance, case-ambient
Lead Solder Temperature
NOTES:
(1)
(2)
(3)
(4)
(5)
CONDITIONS
Peak Test for 2 Seconds
MIN
1500
1500
500
10
TYP
MAX
UNITS
VDC
VDC
VDC
MΩ
pF
µA,
rms
V
ISO
= 240VAC, 60Hz
2000
180
GENERAL
400
12V & higher(4)
Open Collector/Drain
420
-50% / +25%
440
0.5
KHz
V
V
OUT
, Nom
Within 1% of Rated Output
10.0
1.0
0.4
Open Collector
12.5
85 (3.0)
+100
+125
+115
+300
mA
V
mSec
g (oz.)
°C
°C
°C
°C/W
°C
Case Temperature
Case Temperature
Case Temperature
10 Seconds max
-40
-55
+100
+25
+25
7.1
See Typical Performance Curves, page 3
Continuous Mode
See graphs for Efficiency vs. Output Load, V
IN
, T
CASE
3.3V Models Limited in Trim Down Range
Consult Factory for Details
VKA60xS
Rev C
3/2001
Product: www.cdpowerelectronics.com
2
T
CASE
= +40°C nominal input voltage unless otherwise specified.
TYPICAL PERFORMANCE CURVES
VKA60
Device Family
Indicates 60 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
x = Input Voltage (L = 24VDC; M = 48VDC)
zz = Output Voltage (03=3.3V, 05=5V, etc.)
Lead Length
0.200" - No Number
0.145" - (6)
0.110" - (8)
Remote On-Off Logic:
Positive - No Number
Negative - (1)
VKA60xS
Rev C
xSzz -
Product: www.cdpowerelectronics.com
ORDERING
INFORMATION
3/2001
3
MECHANICAL
NOTES:
All dimensions are in inches (millimeters).
0.530 MAX
[13.46]
0.20 [5.1]
PIN PLACEMENT TOLERANCE: ± 0.005"
MECHANICAL TOLERANCE: ± 0.015"
Marked with: specific modeL ordered, date code, job code.
.040 [1.02] DIA.
7 PLACES
.081 [2.06] DIA.
2 PLACES
0.20 [5.1]
0.50 [12.7]
MATERIAL: Units are encapsulated in a low thermal
resistance molding compound which has excellent chemical
resistance and electrical properties in high humidity
environments and over a wide operating temperature range.
The encapsulant and outer shell of the unit have UL94V-0
ratings. Lead material is solder plated to allow ease of
solderability.
0.40 [10.16]
.400 [10.16]
2.000
[50.80]
1.000
[25.40]
2.40
[61.0]
MAX
VKA60xS
0.700
[17.78]
1.000
[25.40]
1.400
[35.56]
1.400
[35.56]
0.19 [4.8]
1.900
[48.26]
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES
MAX. TORQUE, 8 IN/LBS
2.28
[57.91]
MAX
OUTPUT ADJUST VOLTAGE
This feature allows the user to accurately adjust the
module's output voltage set point to a specified level.
This is achieved by connecting a resistor or potentiometer
from the TRIM terminal to either the +Vout terminal (for
increased Vout) or the -Vout terminal (for decreased
Vout). The formulae below describe the trim resistor
value to obtain a Vout change of
∆
%. V
O
is output
voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V).
Radj - up =
OVP NOTE
Special attention should be given to the peak voltage
deviation during a dynamic load step when trimming
the output above the original set point to avoid
tripping the overvoltage protection circuit. Should an
OVP condition occur, the converter will go into a
latch condition and must be externally reset before it
will return to normal operation.
(
Vo(100 +
∆
%)
1.225
∆
%
_
(100 + 2
∆
%)
∆
%
)
kΩ
Radj - down =
(
100
-
2
)
∆
%
kΩ
C&D Technologies (Power Electronics) Ltd.
Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.770.9369
C&D Technologies, (NCL)
Milton Keynes MK14 5BU UK
Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be
accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or
completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from
any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in
user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
Whether it is a switching power supply or a motor drive, engineers are usually tirelessly pursuing three "highs": higher efficiency, higher power density, and higher reliability. However, the existing...
Previously, the horn button was on the solar panel, which was not convenient to press, so I wanted to modify it and move the button to the faucet armrest. Considering that the faucet is small and not ...
[url=http://blog.chinaunix.net/u/166/showart.php?id=2209481]http://blog.chinaunix.net/u/166/showart.php?id=2209481[/url]Test whether the comment function can be used....
EX02 realizes the function of displaying the key input on the digital tube, and EX03 realizes the function of the serial port. The next step is to integrate the functions of EX02 and EX03, and send th...
The SIMILINK module library is divided into the following 8 sub-libraries according to its function: Continuous (continuous module) Discrete (discrete module) Function&Tables (function and platform mo...
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
A parallel inverter consists of two thyristors (T1 and T2), a capacitor, a center-tapped transformer, and an inductor. The thyristors provide a current path, while the inductor L maintains a consta...[Details]
As more and more consumers purchase new energy vehicles, the safety of electric vehicles has become a major concern. This has been particularly prominent following a series of electric vehicle fire...[Details]
In recent years, many people have switched to new energy vehicles, and this type of vehicle has indeed been highly sought after and is considered the future direction of automobile development, and...[Details]
Electric motors and internal combustion engines of the same power have similar torque levels. High power requires high torque, and torque determines a vehicle's acceleration speed, commonly known a...[Details]
In recent years, the government has increasingly supported electric vehicles, and the number of electric vehicles has increased. Observant drivers will notice that there are many more green license...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
Electric vehicles are now widespread, but they've brought with them a host of problems, the most prominent of which is charging. Small electric vehicles (EVs) are a new form of transportation in a ...[Details]
Based on the commutation technology, thyristor rectifiers are classified into two main types. Line-commutated and force-commutated inverters are commonly used, while other commutated inverters, nam...[Details]
In the field of intelligent driving, regulations are becoming increasingly stringent, and the technical threshold continues to rise. Especially after the traffic accident in March 2025, the Ministr...[Details]
In daily life, when we purchase a transformer, we are faced with the installation and wiring procedures. Generally speaking, large transformers such as power transformers are equipped with speciali...[Details]
With the advancement of science and technology and the promotion of green, energy-saving, and circular development, the demand for precise control and accurate measurement is increasing. In the pow...[Details]
MQTT Ethernet I/O modules primarily collect I/O port information and transmit data over the network. In addition to being a TCP server, Ethernet I/O modules can also function as TCP clients. Furthe...[Details]
There are more and more electric vehicles. Recently, I have heard some news about electric vehicles performing poorly in winter. I would like to briefly introduce whether heat pump technology is mo...[Details]
The driving mode is not unfamiliar to vehicles. According to the driving mode of the vehicle, there are front-wheel drive, rear-wheel drive and even four-wheel drive. Four-wheel drive is a major se...[Details]