CFE400M
www.uk.tdk-lambda.com/cfe
Medical
Industrial
Test
Broadcast
Comms
Renewable
300W convection / 400W fan
cooled, AC-DC power supply
Features
• Convection cooled
• Reinforced isolation
• Full digital control
• ErP and Climate Savers Gold Level
• Low Profile
Benefits
Silent operation
Simplifies equipment design
Improves Product Performance
Minimises heat in system
Fits 1U applications
Input
Input Voltage
Input Harmonics
Input Fuse
Earth Leakage Current
85-264Vac (100-240Vac nominal)
EN61000-3-2 compliant
Dual fuses (Live + Neutral)
Fast acting (not user accessible)
Input Frequency
Power Factor
Inrush Current
47 - 63Hz
(440Hz with reduced PFC - consult factory)
0.9 typical
<20A at 25°C and 230Vac (cold start)
(meets EN61000-3-3). <50A for EFE400M
140µA at 120Vac (60Hz), 280µA max at 240Vac (60Hz)
Worst case leakage current is less than 300µA at 240Vac, 63Hz (normal condition, 0.5mA Single Fault Condition)
Quick Selector (Standard models).
Additional variants available - see below
Output
Voltage
12V
24V
48V
Current
(fan/conv)
Convection cooled units / units without fan
U-Chassis
Cover + Chassis
Order Code
Order Code
Description
Description
U7Y0032 CFE400M-12-5C-N1CML-NT
U7Y0054 CFE400M-24-5C-N1CML-NT
U7Y0123 CFE400M-48-5C-N1CML-NT
Units with top fan
Cover + Chassis
Order Code
Description
U7Y0098
U7Y0112
U7Y0145
33.3A /
CFE400M-12-5C-N1UML-NT
25A
16.7A /
CFE400M-24-5C-N1UML-NT
12.5A
8.3A /
CFE400M-48-5C-N1UML-NT
6.25A
U7Y0087 CFE400M-12-5C-TFCML-NT
U7Y0101 CFE400M-24-5C-TFCML-NT
U7Y0134 CFE400M-48-5C-TFCML-NT
How To Create A Product Description
Output
12
24
48
Adjustment
range
10.8 - 14.4 V
21.6 - 28.8 V
43.2 - 50 V
-NN
-N1
-TF
Fan Option
No fan, no fan supply
No fan, 12V / 0.25A fan supply
Top fan, no additional fan supply
(needs ‘F’ cover’)
-Y
= ORing FET included
-N
= ORing FET not included
M
= Molex
Adjustable by potentiometer
CFE400M-
Vout - Standby
Fan
Option
Cover
Input
Earth ORing Remote
Connec-
Leakage FET Of/Off
tor
Standby Supply
NN
= None
(only with ‘N’ remote on/off)
5C
= 5V / 80mA
(0.5W standby mode power)
5H
= 5V / 2A
(1W standby mode power)
U
= Chassis only
C
= Chassis + cover
F
= Cover for top fan (needs ‘TF’ fan)
N
= none
E
= Enable
T
= Inhibit
L
= 300µA
Confirm availability of created product with the factory
CFE400M
1
Isolation
Input to Output
Input to Earth
Reinforced
Basic
4kVac, 5.7kVdc type tested to 4kVac (equivalent to 5.7kVdc), production tested to 4.3kVdc.
1.5kVac, 2.3kVdc
Output to Earth
1.5kVac
Output Specification
Fan cooled Convection
Output Power
Peak Power
Total Regulation
Ripple & Noise
Voltage Setting Accuracy
Turn on Time
Efficiency
Hold up
Min Load
Transient Response
Recovery
Short circuit protection
Over Temperature protection
Over Voltage Protection
Fan supply
400W
450W
300W
450W
Continuous (including fan supply) or RMS (including Peak power)
See handbook for details.
for 10 seconds. RMS power not to exceed Output Power stated above
Including Line regulation of 0.25% (for 90-264Vac input change), Load regulation of 1%
(for 0-100% load change) and thermal regulation of 0.02%/°C (0-50°C)
pk-pk, using EIAJ test method & 20MHz bandwidth
at 50% load
at 90 Vac & 100% rated output power
typical for 48V and 24V (91% for 12V). At 230Vac, 80% load
typical at 100% of 400W load
of set voltage for 50% of 400W load change
(in 50µs within the range 25 - 100% load)
better than 2.25%
1%
±1%
1.5s max
94%
15ms
None
<5%
2ms typical
Yes
Yes
Yes
12V / 0.25A
for recovery to 2% of set voltage
Auto recovery after removal of short circuit
Primary - auto recovers, secondary - cycle power to restart
Latching, need to cycle ac to restart unit.
Depending on ‘Fan Option’ selected. See ‘how to create a product description’ for details
Global Signals
Remote on/off
Standby Supply
Power Good
ORing FET
Enable - TTL logic level low (relative to Standby 0V) enables channel 1 and fan supply
Inhibit - TTL logic level low (relative to Standby 0V) inhibits channel 1 and fan supply
5V / 80mA or 5V / 2A, isolated supply, not affected by remote on/off.
Logic high indicates ac supply is good and Ch1 is within regulation. Not available on units with no standby supply.
Allows redundant connection of power supplies with no additional/external diodes required.
Environment
Temperature
Low Temp Startup
Humidity
See derating chart. Fan cooled is with 1.5m/s air blown from input to output (approximately 12CFM)
450W
-40°C to 70°C storage (max 12 months).
Fan cooling required if the unit is mounted with no free air
400W
Fan cooled
circulation above (see handbook for mounting details)
350W
300W
Output Power
250W
200W
150W
100W
50W
0W
0°
10°
20°
30°
40°
Temperature
50°
60°
70°
80°
-20°C
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27,
IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
Single axis 10 - 500 Hz at 2g (sweep and endurance at
resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1,9
Convection cooled
Shock
Vibration
Altitude
Pollution
Medical approval = -200 to 3000 metres operational (-200 to 5000m storage/transportation)
Non medical approval = -200 to 5000 metres operational (-200 to 5000m storage/transportation)
Degree 2, Material group IIIb
Emissions EN61000-6-3:2007, EN60601-1-2:2001
Radiated Electric Field
Conducted Emissions
Conducted Harmonics
Flicker
EN55011, EN55022
EN55011, EN55022
EN61000-3-2
EN61000-3-3
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
see application note for details
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Class A
Class C - EFE300M at 100W and above
Compliant - d
max
only
2
CFE400M
Immunity EN61000-6-2:2005
Electrostatic Discharge
Electromagnetic Field
Fast / Burst Transient
Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field
Voltage Dips, Variations, Interruptions
Ring Wave
Voltage Fluctuations
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
EN61000-4-12
EN61000-4-14
Level 4
Air discharge 15kV, Contact discharge 8kV
Level 3 for Fan supply
Not applicable to open frame units
12V/m
ac input tested to 4.4kV
dc output tested to 2.2kV
Common mode - 2.2kV
Differential - 1.1kV
12V
10A/m
Criteria B for 5 sec interruption
Criteria B for 1 cycle interruption
Common mode - 2.2kV
Differential - 1.1kV
Criteria
A
Level 3
Level 4
Level 3
Level 3
Level 3
Class 3
Level 3
Class 3
A
A
A
A
A
A
A
A
Safety Approvals
Amendments/notes
IEC/EN 60950-1*
IEC/EN60601-1*
IEC/EN 61010-1
Edition 2
Editions 2 and 3
EFE300M approved
EFE400M designed to meet
UL60950-1 / CSA 22.2 No 60950-1
Amendments/notes
Edition 2 (File E135494)
UL/CSA 60601-1
ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No 60601-1-08
CE Mark (EN60950-1)
2006 (File E349607)
2005
LV Directive 2006/95/EC
* CB certificate and Report available on request
Check with factory for status of approvals
Outline & Connection Drawings
177.80
14.00
150.00
CHASSIS WITH COVER
177.80
20.00
A
100.00
A
100.00
60.00
A
A
6.80
165.00
39.60
20.00
5.65
CHASSIS WITH TOP MOUNTED FAN
177.80
J5
CH1 +VE
J6
PIN 1
0V COMMON
60.50
76.70
J2
J1
J1
14.50
PIN 1
5.40
3.00
PIN CONNECTION
1
2
3
4
5
EARTH
NOT CONNECTED
LIVE
NOT CONNECTED
NEUTRAL
PIN
1
2
3
4
5
6
7
CONNECTION
FAN SUPPLY
REMOTE ON/OFF
PWR GOOD
FAN SUPPLY RTN
STANDBY RTN
STANDBY
- SENSE
+ SENSE
MATING PARTS
CONNECTOR
J1
J2
HOUSING
CRIMP PIN
MANUFACTURER
MOLEX
MOLEX
MOLEX
71.20
49.70
09-50-8051
22-01-2085
N/A
08-52-0113
0850-0032
TAG 19073-0165
J5 & J6
NOTE:
8
Connectors are not included with the product but they are available from
TDK-Lambda
1 off input connector and 3 crimps are available as part number is 94910.
1 off feature connector and 8 crimps are available as part number 95109.
A 6 OFF FIXING HOLES FOR M3, MAXIMUM PENETRATION 3.3mm,
MAXIMUM TORQUE 0.9Nm.
ALL TOLERANCES +/-0.5mm.
40.70
CFE400M
100.00
49.70
3
TDK-LAMBDA EMEA
TDK-Lambda France SAS
Route de Grivery
ZAC des Delaches
CS 41077
91978 Courtaboeuf Cedex
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
france@fr.tdk-lambda.com
www.fr.tdk-lambda.com
www.emea.tdk-lambda.com
TDK-Lambda UK Ltd.
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
powersolutions@uk.tdk-lambda.com
www.uk.tdk-lambda.com
Italy Sales Office
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
info.italia@it.tdk-lambda.com
www.it.tdk-lambda.com
TDK-Lambda Israel
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
info@nemic.co.il
www.tdk-lambda.co.il
TDK-Lambda Germany GmbH
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
info.germany@de.tdk-lambda.com
www.de.tdk-lambda.com
Russia
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
Tel: +7 (499) 7557732
info@tdk-lambda.ru
www.tdk-lambda.ru
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
info.germany@de.tdk-lambda.com
www.de.tdk-lambda.com
Local Distribution
Document number 72709 - Rev 4.4 - February 2012
4
CFE400M