• The ELF series inductors are available in ranging from 0505 to
1010 types.
• Because they are magnetically shielded, these parts can be
used in high-density mounting configurations.
• With a miniature winding construction, these inductors
nonetheless achieve high Q characteristics.
• Available in tape packaging to support automated mounting
machines.
APPLICATIONS
Televisions, VCRs, personal computers, and other electronic
equipment.
SPECIFICATIONS
Operating temperature range
Storage temperature range
Terminal tensile strength
–20 to +80°C
[Including self-temperature rise]
–40 to +80°C [Unit of products]
24.5N min.
ELF Series ELF1010 Type
PRODUCT IDENTIFICATION
ELF 1010 RR- 101 K -3
(1)
(2) (3) (4) (5) (6)
(1)Series name
(2)Dimensions
1010
ø10.5×10.5mm (lead pitch 5mm)
(3)Packaging style
RR
Reel
(4)Inductance value
101
102
100µH
1000µH
(5)Inductance tolerance
J
K
±5%
±10%
(6)TDK internal code
(Some products may not have this number. See the main body
for details.)
PACKAGING STYLE AND QUANTITIES
Packaging style
Reel
Quantity
300 pieces/reel
• All specifications are subject to change without notice.
(2/3)
001-01 / 20030822 / e512_elf1010.fm
Inductors
For General Applications
Radial
REEL TAPING STYLE
SHAPES AND DIMENSIONS
101
K
ELF Series ELF1010 Type
ø10.5max.
14.5max.
33max.
10.5max.
ø0.62±0.05
5+0.8, –0.2
Dimensions in mm
ELECTRICAL CHARACTERISTICS
Inductance
(µH)
100
120
150
180
220
270
330
390
470
560
680
820
1000
1200
1500
1800
2200
2700
3300
3900
4700
5600
6800
8200
10000
12000
15000
18000
22000
27000
33000
39000
47000
∗1
Inductance
tolerance
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
Q min.
50
50
50
50
50
50
50
50
50
40
40
40
60
60
60
60
60
60
60
60
60
60
60
60
40
40
40
40
40
40
40
40
40
Test
frequency
L, Q (kHz)
796
796
796
796
796
796
796
796
796
796
796
796
252
252
252
252
252
252
1
∗3
/252
∗4
1/252
1/252
1/252
1/252
1/252
1/79.6
1/79.6
1/79.6
1/79.6
1/79.6
1/79.6
1/79.6
1/79.6
1/79.6
Self-
resonant
frequency
(MHz)ref.
4.7
4.2
3.8
3.5
3.1
2.8
2.6
2.4
2.2
2
1.8
1.6
1.5
1.4
1.2
1.1
1
0.9
0.81
0.75
0.68
0.63
0.57
0.52
0.47
0.43
0.38
0.34
0.31
0.28
0.25
0.23
0.22
DC
resistance
(Ω)max.
0.66
0.73
0.81
0.89
0.98
1.05
1.15
1.5
1.65
1.9
2.2
2.6
3
3.4
4
4.6
5.4
6.9
8.2
11
14
19
22
25
34
38
43
47
65
74
115
125
145
Rated current (mA)
∗1
max.
Based on
Based on
inductance
temperature
change
rise
580
425
530
405
470
430
430
365
390
350
350
340
320
325
290
285
270
270
245
250
220
235
200
215
180
200
170
190
150
175
135
160
125
150
110
130
100
120
92
105
84
93
77
79
70
74
63
69
57
59
53
56
47
53
43
51
39
43
35
40
32
32
29
31
26
29
Part No.
ELF1010RR-101X
∗2
ELF1010RR-121X
ELF1010RR-151X
ELF1010RR-181X
ELF1010RR-221X
ELF1010RR-271X
ELF1010RR-331X
ELF1010RR-391X
ELF1010RR-471X
ELF1010RR-561X
ELF1010RR-681X
ELF1010RR-821X
ELF1010RR-102X
ELF1010RR-122X
ELF1010RR-152X
ELF1010RR-182X
ELF1010RR-222X
ELF1010RR-272X
ELF1010RR-332X
ELF1010RR-392X
ELF1010RR-472X
ELF1010RR-562X
ELF1010RR-682X
ELF1010RR-822X
ELF1010RR-103X
ELF1010RR-123X
ELF1010RR-153X
ELF1010RR-183X
ELF1010RR-223X
ELF1010RR-273X
ELF1010RR-333X
ELF1010RR-393X
ELF1010RR-473X
Rated current: Value obtained when current flows and the temperature has risen to 20°C or when DC current flows and the initial value of inductance has
fallen by 10%, whichever is smaller.
∗2
X: Please specify inductance tolerance, K(±10%) or J(±5%)
∗3
for L
∗4
for Q
• ELF1010(100µH to 2.7mH) L, Q, Rdc, SRF: are the same as ELF0505, 0607 and 0708
• ELF1010(3.3 to 100mH) L:LCR METER MODEL 4261A YHP, or equivalent Q, Rdc, SRF:are the same as ELF0505, 0607 and 0708
• L measuring instrument differs from others, because measurement frequency is 1kHz.
• All specifications are subject to change without notice.
(3/3)
001-01 / 20030822 / e512_elf1010.fm
Inductors
For General Applications
Radial
ELECTRICAL CHARACTERISTICS
Inductance
(µH)
56000
68000
82000
100000
∗1
ELF Series ELF1010 Type
Inductance
tolerance
±10, ±5%
±10, ±5%
±10, ±5%
±10, ±5%
Q min.
40
30
30
30
Test
frequency
L, Q (kHz)
1
∗3
/79.6
∗4
1/79.6
1/79.6
1/79.6
Self-
resonant
frequency
(MHz)ref.
0.2
0.18
0.17
0.15
DC
resistance
(Ω)max.
190
215
290
330
Rated current (mA)
∗1
max.
Based on
Based on inductance
temperature
change
rise
24
25
22
24
20
20
18
19
Part No.
ELF1010RR-563X
∗2
ELF1010RR-683X
ELF1010RR-823X
ELF1010RR-104X
Rated current: Value obtained when current flows and the temperature has risen to 20°C or when DC current flows and the initial value of inductance has
fallen by 10%, whichever is smaller.
∗2
X: Please specify inductance tolerance, K(±10%) or J(±5%)
∗3
for L
∗4
for Q
• ELF1010(100µH to 2.7mH) L, Q, Rdc, SRF: are the same as ELF0505, 0607 and 0708
• ELF1010(3.3 to 100mH) L:LCR METER MODEL 4261A YHP, or equivalent Q, Rdc, SRF:are the same as ELF0505, 0607 and 0708
• L measuring instrument differs from others, because measurement frequency is 1kHz.
TYPICAL ELECTRICAL CHARACTERISTICS
INDUCTANCE CHANGE vs. DC SUPERPOSITION
CHARACTERISTICS
100000
50000
Test circuit L=5H C=20000µF
A
DC
Specimen
15000µH
10000
5000
Inductance (
µH
)
10000µH
3300µH
INDUCTANCE CHANGE vs. TEMPERATURE
CHARACTERISTICS
6
∆L
/L (%)
4
2
0
–20
1000µH
10000µH
100000µH
100µH
0
–2
–4
–6
80
60
20 40
Temperature (˚C)
100000µH
100µH
10000µH
1000µH
1000
500
1000µH
LCR
meter
YHP 4275A LCR METER
f=10kHz
330µH
Q vs. FREQUENCY CHARACTERISTICS
100
50
100µH
140
120
100
Q
10
1
5
10
50 100
DC current (mA)
500 1000
80
1000µH
60
40
Q-METER 4340A YHP
20
0.02 0.05 0.1 0.2
0.5 1
2
5
Frequency (MHz)
10 20
50
10000µH
100µH
100000µH
• All specifications are subject to change without notice.
[size=4] It’s been a week since the Renesas DIY event ended. I’d like to share with you the progress of the awards. [/size] [size=4] Regarding this Renesas DIY event ([/size][size=4][url=https://www.e...
If you want to charge faster, can you connect several chargers in parallel to charge the electric bicycle battery? Besides, you can estimate that you don't need to charge when it reaches the floating ...
[i=s]This post was last edited by dcexpert on 2019-10-3 12:07[/i]Before proceeding to the next test, you need to prepare the development software. ATmega4809 belongs to the AVR microcontroller series ...
Where can I find a download of the ARM Cortex-m3/m4 assembly instruction summary table? It would be best if the description is in Chinese or English. Thank you....
Our company has CSTN and TFT LCD screen control driver boards, which can be controlled by 51 single-chip microcomputers and can display 256--65536 colors. They are low-priced and easy to program. They...
I am doing an experiment on measuring pulse wave recently. The first step of the software is to use the 12-bit AD in the chip for sampling. 1) I set the clock and AD according to the values in the dat...
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
To differentiate their products in a crowded and competitive market, manufacturers of handheld devices often consider battery life and power management as key selling points for cell phones, PDAs, ...[Details]
July 11, 2012, Beijing - Altera Corporation (NASDAQ: ALTR) today announced the launch of 40-Gbps Ethernet (40GbE) and 100-Gbps Ethernet (100GbE) intellectual property (IP) core products. These core...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
In the single-chip microcomputer system, in addition to display devices, sound devices are often used, and the most common sound device is the buzzer. Buzzers are generally used for some low-demand...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
12v Lead Acid batteries used in trucks, cars, RVs and uninterruptible power supplies are usually rated at 12V. This circuit monitors the battery, the charge and discharge curves, gives the cu...[Details]
Capacitance Measurement
Used to verify that capacitors meet the manufacturer's specifications. For quality control, a group of capacitors may be placed in an environmental chamber and the cap...[Details]
Introduction
Automakers are working to reduce vehicle weight to reduce CO2 emissions and improve fuel efficiency. Designers are therefore seeking new technologies and design techniques that can...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]