PB10Q-50-1ASSI

Description
10A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET
CategoryThe connector    The connector   
File Size272KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

PB10Q-50-1ASSI Overview

10A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET

PB10Q-50-1ASSI Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; VDE, QUICK CONNECT
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings10A, 115/250VAC
Manufacturer's serial numberPB
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
POWER LINE FILTER
PB Series
STRAIGHT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
50.1
30.3
22.5
40.0
28.5
4-R5
21.6
2-
3.3
40.0
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.9
47.4
41.8
54.0
FEATURES
The PB series, similar to PA and PASP series, offers filters with
IEC connector providing effective equipment protection of
line-to-ground noise up to 15 Amp, 250VAC. The compact
design filter with low leakage current is well suited for
applications that require strict national and international
emission standards. These filters are also available for
Medical application and offer extremely low Leakage current
to comply with UL544, UL2601 and CSA22.2 standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
G
28.3
20.6
31.0
24.0
21.9
4-R2
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
28.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
3.6
51.8
40.9
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
7
If you were to build a smart home system, which mobile phone module would you choose?
If you were to build a smart home system, which mobile phone module would you choose? [[i] This post was last edited by zhaojun_xf on 2010-7-22 05:50[/i]]...
zhaojun_xf DIY/Open Source Hardware
Serial communication 24bit
Excuse me, I want to use one serial port to send three sets of different data. Is there any good way? I send three sets separately, but they cannot be separated at the receiving end....
xiaoliangzz Microcontroller MCU
Square root calculation of LM4F232
I have a question. The square root I calculated using the isqrt function in the M4 library is an integer. Is there a floating-point square root library function?...
skytianlin Microcontroller MCU
A question about MMC
Today I read a post about MMC problem, and then I checked some of the latest android4.1.2 kernel source code, and found that the problem still exists. I posted the content here for everyone to browse,...
yinhu DSP and ARM Processors
Share the document "BeagleBone Rev A3 System Reference Manual.pdf"
You can take a look! After reading it, I feel that this information is still very useful! Sorry, I sent it to the wrong page!! [[i] This post was last edited by wuyanyanke on 2012-10-24 02:20 [/i]]...
wuyanyanke DSP and ARM Processors
Serial port screen button sending problem
In one interface of my serial port screen, some of the buttons can make the microcontroller work every time they are pressed, but some of them need to be pressed several times before the microcontroll...
有容乃大 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1602  2101  2800  433  2028  33  43  57  9  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号