EEWORLDEEWORLDEEWORLD

Part Number

Search

KUM-11D26-6

Description
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.187A (COIL), 6VDC (COIL), 1200mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size538KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

KUM-11D26-6 Overview

POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.187A (COIL), 6VDC (COIL), 1200mW (COIL), PANEL MOUNT

KUM-11D26-6 Parametric

Parameter NameAttribute value
MakerTE Connectivity
Reach Compliance Codeunknown
ECCN codeEAR99
Maximum coil current (DC)0.187 A
Coil operating voltage (DC)4.5 V
Coil power1200 mW
Coil resistance32.1 Ω
Maximum coil voltage (DC)6 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load15A@277VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)277 V
Contact/Output Power TypeAC
Electrical life100000 Cycle(s)
Manufacturer's serial numberKU
Installation featuresPANEL MOUNT
operating hours15 ms
Maximum operating temperature85 °C
Minimum operating temperature-45 °C
GuidelineCSA
Relay actionMOMENTARY
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time10 ms
sealDUST PROOF
surface mountNO
Termination typeSOLDER
Catalog 1308242
Issued 3-03 (PDF Rev. 1-06)
P&B
KU
series
KUP Enclosed Relay
KUIP 8mm Coil to Contacts
KUGP 3mm Contact Gap, 8mm Coil to Contacts
KUEP 10 Amp 150VDC Load Switching
KUMP 15 Amp 277VAC
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Features
• AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC.
• Contact arrangement up to 4PDT.
• Wide selection of termination and mounting styles.
• PC terminals available.
• Push to test button and indicator lamps.
• KUEP incorporates a blow out magnet for high voltage DC switching.
• KUIP offers 8mm contact-to-coil spacing for a higher degree of isolation.
• KUGP provides 3mm contact gap and 8mm contact-to-coil spacing.
• Complete line of sockets and DIN rail.
• Class B coil insulation.
Coil Data @ 25°C
Voltage:
6 to 110VDC and 6 to 240VAC.
Nominal Coil Power:
DC Coils:
1.2 Watts - KUP KUIP KUMP 1 - 3 pole; KUEP 1 pole.
,
,
,
,
DC Coils:
1.8 Watts - KUP 4 pole; KUEP 2 pole; KUGP
,
,
.
AC Coils:
2.0VA - KUP KUIP 1 - 2 pole; KUEP 1 pole.
,
,
,
AC Coils:
2.7VA - KUP KUIP 3 pole; KUEP 2 pole; KUGP KUMP
,
,
,
,
.
Coil Data
Contact Data @ 25°C
Arrangements:
See respective ordering information table.
Materials:
Fine silver (5 amp) silver-cadmium oxide (10 amp).
Gold flash available as standard.
Gold diffused and gold alloy on special order.
Expected Mechanical Life:
Contact Ratings
Material
Fine
Silver
Arrangement
All
UL/CSA Ratings
5 amps @ 28VDC or 240VAC
80% PF 2.5 amp tungsten
,
@120VAC, 1/2 amp @ 120VDC.
1/6 HP @120VAC, 1/3 HP @
240VAC, 5 FLA, 15 LRA @
250VAC (FLA covered by
30,000 operations).
10 amps @ 28VDC or 240VAC,
80% PF 5 amp tungsten @
,
120VAC, 3A 600VAC, 1/2 amp
@ 120VDC.
1/3 HP @ 120VAC, 1/2 HP @
240, 480, and 600VAC, 10 FLA
30 LRA @ 120VAC, 5 FLA,
15 LRA @ 250VAC.(FLA ratings
covered by 30,000 operations)
15 amp @ 277VAC, 80% PF
KUM KUMP
10 amp @ 28VDC or 120VAC,
80% PF 6 2/3 amp @ 240VAC,
,
80% PF
10 amp per pole not to exceed
30 amp total @ 28VDC, 120VAC,
80% PF 6 2/3 amp @ 240VAC,
,
80% PF
10 amp @ 150VDC
5 amp @ 150VDC
3 amp @ 150VDC
100,000
Expected
Life
DC Volts
Nominal
5
6
12
24
48
110
AC Volts
Nominal
6
12
24
120
240
1.2 Watt
1.8 Watt
DC Ohms ± 10% Nom. I ma DC Ohms ± 10% Nom. I ma
21
238
14
360
32.1
187
20
300
120
100
80
150
472
51
320
75
1,800
26.7
1,260
38
10,000
11
6,720
16
2VA
DC Ohms ± 15%
6
24
85
2,250
9,110
2.7VA
Nom. I ma DC Ohms ± 15% Nom. I ma
335
168
84
17
.5
8.75
4.2
18
72
1,700
7
,200
460
230
115
24
12
100,000
Silver-
Cadmium
Oxide
1-2 Pole
KUP
KUIP
KUGP
KUEP
All KUMP
Operate Data @ 25°C
100,000
KUMP
3 Pole
KUP
KUIP
4 Pole
Must Operate Voltage:
DC Coils:
75% of nominal voltage or less.
AC Coils:
85% of nominal voltage or less.
Operating Time (Excluding Bounce):
15 milliseconds, typical, at nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds, typical, at nominal voltage.
100,000
100,000
Environmental Data
100,000
KUEP
SPST-NO
KUEP
2PST-NO
KUEP
2PDT
(All other AC ratings apply KUEP
.)
Temperature Range:
Operating: Enclosed Relays:
-45°C to maximum listed in table below.
Open Relays:
Add 15°C to maximum listed.
Max C°
KUP
KUIP
KUGP
KUEP
KUMP
AC
2 pole
AC
3 pole
DC
2 pole
+45°C
AC
3-4 pole
+50°C
DC
4 pole
+55°C
+70°C
+75°C
+80°C
+95°C
AC
DC
1-2 pole 1-3 pole
AC
3 pole
AC
2 pole
AC
DC
1 pole
1 pole
AC
DC
1-2 pole 1-3 pole
AC
1-2 pole
DC
2 pole
DC
1-3 pole
Initial Dielectric Strength
Between Open Contacts:
1,200V rms; KUGP 3,500V rms.
,
Between Adjacent Contacts:
2,200V rms.
Between Contacts and Coil:
2,200V rms; KUGP KUIP 3,750V rms.
,
,
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
723
Part-time job - Embedded Linux + Android related product development
I have many years of experience in embedded Linux + Android development, many years of Linux driver and application development and Android driver and application development. I mainly develop gateway...
吃萝卜的猴子 Recruitment
Using micro libraries in MDK
Microlib is a subset of the standard library. Some infrequently used functions are not included in it. When using microlib, some functions cannot be used. As for MicroLib, do not use it lightly. Becau...
ye0217 Embedded System
使用 PIC12F675 A/D的問題
如下程式,時鐘用內帶的4M振蕩器,程序無法完成AD轉換,停留在 while(AD_DONE);#includestaticbit AD_DONE@((unsigned)ADCON0*8)+2; .........(其它定義)void main(void) {CMCON = 0x7;//關閉比較器,設定GP0,GP1,GP2為GPIO。TRISIO = 0xb;ANSEL = 0x51;ADCON0...
nuaajiang Microchip MCU
Is there a difference in the MBR storage location between a 1G SD card and a 2G SD card, or is there a difference in the timing of reading the SD card BLOCK cmd?
I am making a program to upgrade NK with SD card in the BOOT of my development platform, which needs to support 2G SD card. At present, my 1G card FAT16 card can read 0BLOCK 512 bytes to get MBR, and ...
回到当下 Embedded System
Questions about Connection Management
What is the essential purpose of the connection manager? The description on MSDN is too simple, so I doubt its necessity... Does a connection manager also need to be used to help connect when using a ...
wangjun01 Embedded System
VHDL keystroke problem
[i=s] This post was last edited by paulhyde on 2014-9-15 03:15 [/i] I am using FPGA chip to implement a dual-channel adjustable phase difference signal generator. The signal frequency range is adjusta...
那只叫冬菇的猫 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 284  768  1618  1756  833  6  16  33  36  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号