EEWORLDEEWORLDEEWORLD

Part Number

Search

8LT025F46BA

Description
MIL Series Connector, 46 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size150KB,1 Pages
ManufacturerSOURIAU
Environmental Compliance  
Download Datasheet Parametric View All

8LT025F46BA Online Shopping

Suppliers Part Number Price MOQ In stock  
8LT025F46BA - - View Buy Now

8LT025F46BA Overview

MIL Series Connector, 46 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle

8LT025F46BA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
MakerSOURIAU
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999, COMPATIBLE CONTACTS: 8599-0707900, 8599-0708900
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeBAYONET
DIN complianceNO
empty shellYES
Environmental characteristicsFLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsYES
Installation typeCABLE AND PANEL
OptionsHERMETIC
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size25
Termination typeCRIMP
Total number of contacts46
8LT Series
Dimensions
Receptacle type 0
Panel cut out
Shell size
B1
E1
D1
J
L1
L2
L3
d
J1
e
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
± 0.15
Min
Max
09
23.70
24.30
18.26
1
4.40
1
4.53
3.25
3.35
1
5.93
16.05
1
3.23
1
3.49
2.1
4
2.54
1
5.70
3.25
18.26
1
1
26.05
26.70
20.62
1
7.65
1
7.78
3.25
3.35
1
5.93
16.05
1
3.23
1
3.49
2.1
4
2.54
18.70
3.25
20.62
1
3
28.50
29.05
23.01
21.40
21.59
3.25
3.35
1
5.93
16.05
1
3.23
1
3.49
2.1
4
2.54
21.80
3.25
23.01
15
30.85
31.45
24.61
24.65
24.77
3.25
3.35
1
5.93
16.05
1
3.23
1
3.49
2.1
4
2.54
25.00
3.25
24.61
1
7
33.20
33.80
26.97
27.82
27.94
3.25
3.35
1
5.93
16.05
1
3.23
1
3.49
2.1
4
2.54
28.30
3.25
26.97
1
9
36.40
37.00
29.36
29.24
30.66
3.25
3.35
1
5.93
16.05
1
3.23
1
3.49
2.1
4
2.54
31.00
3.25
29.36
21
39.55
40.1
5
31.75
33.70
33.83
3.25
3.35
1 7
5.1
1
5.29
1
3.23
1
3.49
2.90
3.30
34.20
3.25
31.75
23
42.75
43.35
34.93
36.92
37.00
3.73
3.83
1 7
5.1
1
5.29
1
3.23
1
3.49
2.90
3.30
37.30
3.91
34.92
25
46.00
46.50
38.10
40.06
40.18
3.73
3.83
1 7
5.1
1
5.29
1
3.23
1
3.49
2.90
3.30
40.50
3.91
38.10
Cable connecting receptacle type 1
*
Shell size
B1
E1
D1
L1
L2
L3
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
09
18.35
18.92
21.80
22.35
1
4.40
1
4.53
1
5.93
16.05
1
3.23
1
3.45
2.1
4
2.54
1
1
21.65
22.22
25.10
25.65
1
7.65
1
7.78
1
5.93
16.05
1
3.23
1
3.45
2.1
4
2.54
1
3
25.05
25.62
28.50
29.05
21.40
21.59
1
5.93
16.05
1
3.23
1
3.45
2.1
4
2.54
15
27.25
27.82
30.70
31.25
24.65
24.77
1
5.93
16.05
1
3.23
1
3.45
2.1
4
2.54
1
7
30.78
31.35
34.10
34.65
27.82
27.94
1
5.93
16.05
1
3.23
1
3.45
2.1
4
2.54
1
9
34.05
34.62
37.50
38.05
29.24
30.66
1
5.93
16.05
1
3.23
1
3.45
2.1
4
2.54
21
37.45
38.02
40.90
41.45
33.70
33.83
1 7
5.1
1
5.29
1
3.23
1
3.45
2.90
3.30
23
41.45
42.02
44.90
45.45
36.92
37.00
1 7
5.1
1
5.29
1
3.23
1
3.45
2.90
3.30
25
45.93
46.50
49.40
49.95
40.06
40.18
1 7
5.1
1
5.29
1
3.23
1
3.45
2.90
3.30
Dimensions in millimeters
* Detail A see page 27
21
How to configure wireless router
I have a 54M wireless broadband router. After configuration, the download speed of Thunder was about 30k at the beginning. It was connected to the 2m network of China Railway Communications Corporatio...
pchild Embedded System
Competition essential DDS module MSP430 AD9850 program
Using MSP430 to control DDS chip AD9850...
yuxizhe Microcontroller MCU
ADS1115 uses IIc to configure the register and point to the register. Then the value read out is all 1, which is 65535
[i=s] This post was last edited by dontium on 2015-1-23 11:08 [/i] No one knows why. Did I make a mistake in the input or did I misconfigure it? I’ll make the program available for everyone to see. vo...
Forever_092 Analogue and Mixed Signal
Give everyone something useful
Make good use of it!...
realdyp PCB Design
Mobile phone battery charging and discharging protection circuit
I would like to ask if anyone has a mobile phone battery charge and discharge protection circuit . I need it urgently now. I hope you can help me . Thank you!!...
dianzijie5 Power technology
About Siemens TD400 programming issues
There is a project that wants to use TD400 for status monitoring. The specific requirement is that when the data in the register is 1, it will display "moving forward ", and when the data is 2, it wil...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2215  1221  680  2279  1526  45  25  14  46  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号