Part Number

Search

802-010-07ZM7-10PB

Description
Circular Connector, 10 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size231KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

802-010-07ZM7-10PB Overview

Circular Connector, 10 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,

802-010-07ZM7-10PB Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialSTAINLESS STEEL
Housing size7
Termination typeCRIMP
Total number of contacts10
Series 802 “Aqua Mouse”
3500 PSI Rated
Series 802 Receptacles
A
Immersion Rated
to 3500 PSI. A
piston o-ring provides sealing to the
mating plug.
panel mounting, or in-line receptacles
for free-hanging cables.
Two Shell Styles:
Choose the
integral band platform for direct
attachment of a cable shield. Install
a boot, or overmold a boot over the
band platform. An accessory thread
is available for attaching strain reliefs
and backshells.
Jam Nut, Rear Mount
Nut
Moun
316 Series
Stainless Steel
shells
offer maximum resistance to
mechanical and environmental abuse.
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
Square Flange
HOW TO ORDER SERIES 802 CRIMP RECEPTACLES
Sample Part Number
8 0 2- 0 11
Series
-02
Shell Style
ZM
Shell Material /
Finish
Z1
Stainless Steel /
Passivated
10 -26
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
P
Contact Type
B
Shell Key
Position
A
802-010
Receptacle with
Banding Platform
-01
In-Line
ZM
Stainless Steel /
Electroless Nickel
Plated
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
Normal
B
Pos. B
P
Pin
C
Pos. C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Pos. D
802-011
Receptacle with
Accessory Thread
-02
Square Flange
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
-07
Jam Nut for Rear
Panel Mounting
H
Socket
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-5
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 800
B
C
D
E
F
G
H
J
K
L
M
What are the mainstream near-field communication solutions now?
I would like to ask you seniors, what are the mainstream near-field communication solutions on the market now, and which manufacturers have such products?...
犹豫的大三 Integrated technical exchanges
[Transfer] Class D audio amplifier design: concepts, principles and methods
[p=15, null, left][color=rgb(0, 0, 0)][font=Arial, Helvetica, sans-serif][size=12px]By Eric Gaalaas[/size][/font][/color][/p][hr][p=15, null, left][color=rgb(0, 0, 0)][font=Arial, Helvetica, sans-seri...
dontium Energy Infrastructure?
The differences and problems between traditional PLC and PC control
:( Traditional PLC refers to a programmable controller designed according to the requirements of processing logical operations and sequential control, using a dedicated hard real-time operating system...
jek9528 Industrial Control Electronics
Do you want to participate in such a post?
Based on the post "Retain the beautiful scenery around you", I have an idea to post a theme post for each season of the year. You can share some photos or interesting things, or you can share a delici...
mmmllb Talking
Why does BTS723 have 9V output?
VCC=DC24V, when s3 or s4 is pressed, it can output 24V, when S3 or S4 is not pressed, why does BTS723 have 9V output? According to the PDF, it should output 0 [[i] This post was last edited by simonpr...
simonprince Analog electronics
IO port photoelectric isolation problem
I would like to ask about the I/O input and output. In the process of system design, all input and output digital quantities are photoelectrically isolated. Photoelectric isolation can effectively sup...
wolfjj DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 178  156  2536  1988  709  4  52  41  15  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号