ELECTRICAL SPECIFICATION @ Tamb = 25°C
PART
NUMBER
UNI-POLAR
DEVICE
CODE
REVERSE
STANDOFF
VOLTAGE
V
R
(Volts)
MIN
P6SMBJ 6V8 / P6SMBJ 6V8C
P6SMBJ 6V8A / P6SMBJ 6V8CA
P6SMBJ 7V5 / P6SMBJ 7V5C
P6SMBJ 7V5A / P6SMBJ 7V5CA
P6SMBJ 8V2 / P6SMBJ 8V2C
P6SMBJ 8V2A / P6SMBJ 8V2CA
P6SMBJ 9V1 / P6SMBJ 9V1C
P6SMBJ 9V1A / P6SMBJ 9V1CA
P6SMBJ 10 / P6SMBJ 10C
P6SMBJ 10A / P6SMBJ 10CA
P6SMBJ 11 / P6SMBJ 11C
P6SMBJ 11A / P6SMBJ 11CA
P6SMBJ 12 / P6SMBJ 12C
P6SMBJ 12A / P6SMBJ 12CA
P6SMBJ 13 / P6SMBJ 13C
P6SMBJ 13A / P6SMBJ 13CA
P6SMBJ 15 / P6SMBJ 15C
P6SMBJ 15A / P6SMBJ 15CA
P6SMBJ 16 / P6SMBJ 16C
P6SMBJ 16A / P6SMBJ 16CA
P6SMBJ 18 / P6SMBJ 18C
P6SMBJ 18A / P6SMBJ 18CA
P6SMBJ 20 / P6SMBJ 20C
P6SMBJ 20A / P6SMBJ 20CA
P6SMBJ 22 / P6SMBJ 22C
P6SMBJ 22A / P6SMBJ 22CA
P6SMBJ 24 / P6SMBJ 24C
P6SMBJ 24A / P6SMBJ 24CA
P6SMBJ 27 / P6SMBJ 27C
P6SMBJ 27A / P6SMBJ 27CA
P6SMBJ 30 / P6SMBJ 30C
P6SMBJ 30A / P6SMBJ 30CA
P6SMBJ 33 / P6SMBJ 33C
P6SMBJ 33A / P6SMBJ 33CA
P6SMBJ 36 / P6SMBJ 36C
P6SMBJ 36A / P6SMBJ 36CA
P6SMBJ 39 / P6SMBJ 39C
P6SMBJ 39A / P6SMBJ 39CA
P6SMBJ 43 / P6SMBJ 43C
P6SMBJ 43A / P6SMBJ 43CA
P6SMBJ 47 / P6SMBJ 47C
P6SMBJ 47A / P6SMBJ 47CA
P6SMBJ 51 / P6SMBJ 51C
P6SMBJ 51A / P6SMBJ 51CA
Notes:
1. Testing is performed @ 25˚
2. Bv is measured using a pulse of 20 milliseconds or less
3. V
F
, for uni-diectional devices, is measured using a 300 microsecond square wave pulse @
I
T
= 50A
4.
I
R
is doubled for Bi-directional devices only with V
R
equal or less than 10 volts
6V8 / 6V8C
6V8A /6V8CA
7V5 / 7V5C
7V5A / 7V5CA
8V2 / 8V2C
8V2A / 8V2CA
9V1 / 9V1C
9V1A / 9V1CA
10 / 10C
10A / 10CA
11 / 11C
11A / 11CA
12 / 12C
12A / 12CA
13 / 13C
13A / 13CA
15 / 15C
15A / 15CA
16 / 16C
16A / 16CA
18 / 18C
18A / 18CA
20 / 20C
20A / 20CA
22 / 22C
22A / 22CA
24 / 24C
24A / 24CA
27 / 27C
27A / 27CA
30 / 30C
30A / 30CA
30 / 33C
33A / 33CA
36 / 36C
36A / 36CA
39 / 39C
39A / 39CA
43 / 43C
43A / 43CA
47 / 47C
47A / 47CA
51 / 51C
51A / 51CA
5.50
5.80
6.05
6.40
6.63
7.02
7.37
7.78
8.10
8.55
8.92
9.40
9.72
10.2
10.5
11.1
12.1
12.8
12.9
13.6
14.5
15.3
16.2
17.1
17.8
18.8
19.4
20.5
21.8
23.1
24.3
25.6
26.8
28.2
29.1
30.8
31.6
33.3
34.8
36.8
38.1
40.2
41.3
43.6
6.12
6.45
6.75
7.13
7.38
7.79
8.19
8.65
9.00
9.50
9.90
10.50
10.80
11.40
11.70
12.40
13.50
14.30
14.40
15.20
16.20
17.10
18.00
19.00
19.80
20.90
21.60
22.80
24.30
25.70
27.00
28.50
29.70
31.40
32.40
34.20
35.10
37.10
38.70
40.90
42.30
44.70
45.90
48.50
BREAKDOWN
VOLTAGE
V
BR
(Volts) @
I
T
MAX
7.48
7.14
8.25
7.88
9.02
8.61
10.00
9.55
11.00
10.50
12.10
11.60
13.20
12.60
14.30
13.70
16.50
15.80
17.60
16.80
19.80
18.90
22.00
21.00
24.20
23.10
26.40
25.20
29.70
28.40
33.0
31.50
36.30
34.70
39.60
37.80
42.90
41.00
47.30
45.20
51.70
49.40
56.10
53.60
10.0
10.0
10.0
10.0
10.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1000.0 (4)
1000.0 (4)
500.0 (4)
500.0 (4)
200.0 (4)
200.0 (4)
50.0 (4)
50.0 (4)
10.0 (4)
10.0 (4)
5.0 (4)
5.0 (4)
5.0 (4)
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
MAXIMUM
REVERSE
LEAKAGE
I
R
@ V
R
(µA)
MAXIMUM
CLAMPING
VOLTAGE
V
C
@
I
PP
(Volts)
(mA)
10.8
10.5
11.7
11.3
12.5
12.1
13.8
13.4
15.0
14.5
16.2
15.6
17.3
16.7
19.0
18.2
22.0
21.2
23.5
22.5
26.1
25.2
29.1
27.7
31.9
30.6
34.7
33.2
39.1
37.5
43.5
41.4
47.7
45.7
52.0
49.9
56.4
53.9
61.9
59.3
67.8
64.8
73.5
70.1
MAXIMUM MAXIMUM
PEAK PULSE FORWARD
CURRENT
VOLTAGE
I
PP
@ V
C
(V
F
) @
I
T
(A)
(Volts)
56.0
57.0
51.0
53.0
48.0
50.0
44.0
45.0
40.0
41.0
37.0
38.0
35.0
36.0
32.0
33.0
27.0
28.0
26.0
27.0
23.0
24.0
21.0
22.0
19.0
20.0
17.0
18.0
15.0
16.0
14.0
14.4
12.6
13.2
11.6
12.0
10.5
11.2
9.6
10.1
8.9
9.3
8.2
8.6
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
All products are sold to the commercial specifications shown, for any additional reliability testing or extended parameters, please consult the factory.
contact semitron on: telephone:
+44 (0)1793 724000
fax:
+44 (0)1793 720401
9
ELECTRICAL SPECIFICATION @ Tamb = 25°C
PART
NUMBER
UNI-POLAR
DEVICE
CODE
REVERSE
STANDOFF
VOLTAGE
V
R
(Volts)
MIN
P6SMBJ 56 / P6SMBJ 56C
P6SMBJ 56A / P6SMBJ 56CA
P6SMBJ 62 / P6SMBJ 62C
P6SMBJ 62A / P6SMBJ 62CA
P6SMBJ 68 / P6SMBJ 68C
P6SMBJ 68A / P6SMBJ 68CA
P6SMBJ 75/ P6SMBJ 75C
P6SMBJ 75A / P6SMBJ 75CA
P6SMBJ 82 / P6SMBJ 82C
P6SMBJ 82A / P6SMBJ 82CA
P6SMBJ 91 / P6SMBJ 91C
P6SMBJ 91A / P6SMBJ 91CA
P6SMBJ 100 / P6SMBJ 100C
P6SMBJ 100A / P6SMBJ 100CA
P6SMBJ 110 / P6SMBJ 110C
P6SMBJ 110A / P6SMBJ 110CA
P6SMBJ 120 / P6SMBJ 120C
P6SMBJ 120A / P6SMBJ 120CA
P6SMBJ 130 / P6SMBJ 130C
P6SMBJ 130A / P6SMBJ 130CA
P6SMBJ 150 / P6SMBJ 150C
P6SMBJ 150A / P6SMBJ 150CA
P6SMBJ 160 / P6SMBJ 160C
P6SMBJ 160A / P6SMBJ 160CA
P6SMBJ 170 / P6SMBJ 170C
P6SMBJ 170A / P6SMBJ 170CA
P6SMBJ 180 / P6SMBJ 180C
P6SMBJ 180A / P6SMBJ 180CA
P6SMBJ 200 / P6SMBJ 200C
P6SMBJ 200A / P6SMBJ 200CA
P6SMBJ 220 / P6SMBJ 220C
P6SMBJ 220A / P6SMBJ 220CA
Notes:
1. Testing is performed @ 25˚
2. Bv is measured using a pulse of 20 milliseconds or less
3. V
F
, for uni-diectional devices, is measured using a 300 microsecond square wave pulse @
I
T
= 50A
4.
I
R
is doubled for Bi-directional devices only with V
R
equal or less than 10 volts
56 / 56C
56A / 56CA
62 / 62C
62A / 62CA
68 / 68C
68A / 68CA
75 / 75C
75A / 75CA
82 / 82C
82A / 82CA
91 / 91C
91A / 91CA
100 / 100C
100A / 100CA
110 / 110C
110A / 110CA
120 / 120C
120A / 120CA
130 / 130C
130A / 130CA
150 / 150C
150A / 150CA
160 / 160C
160A / 160CA
170 / 170C
170A / 170CA
180 / 180C
180A / 180CA
200 / 200C
200A / 200CA
220 / 220C
220A / 220CA
45.4
47.8
50.2
53.0
55.1
58.1
60.7
64.1
66.4
70.1
73.7
77.8
81.0
85.5
89.2
94.0
97.2
102.0
105.0
111.0
121.0
128.0
130.0
136.0
138.0
145.0
146.0
154.0
162.0
171.0
175.0
185.0
50.40
53.20
55.80
58.90
61.20
64.60
67.50
71.30
73.80
77.90
81.90
86.50
90.00
95.00
99.00
105.00
108.00
114.00
117.00
124.00
135.00
143.00
144.00
152.00
153.00
162.00
162.00
171.00
180.00
190.00
198.00
209.00
BREAKDOWN
VOLTAGE
V
BR
(Volts) @
I
T
MAX
61.60
58.80
68.20
65.10
74.80
71.40
82.50
78.80
90.20
86.10
100.00
95.50
110.00
105.00
121.00
116.00
132.00
126.00
143.00
137.00
165.00
158.00
176.00
168.00
187.00
179.00
198.00
189.00
220.00
210.00
242.00
231.00
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
MAXIMUM
REVERSE
LEAKAGE
I
R
@ V
R
(µA)
MAXIMUM
CLAMPING
VOLTAGE
V
C
@
I
PP
(Volts)
(mA)
80.5
77.0
89.0
85.0
98.0
92.0
108.0
103.0
118.0
113.0
131.0
125.0
144.0
137.0
158.0
152.0
173.0
165.0
187.0
179.0
215.0
207.0
230.0
219.0
244.0
234.0
258.0
246.0
287.0
274.0
344.0
328.0
MAXIMUM MAXIMUM
PEAK PULSE FORWARD
CURRENT
VOLTAGE
I
PP
@ V
C
(V
F
) @
I
T
(A)
(Volts)
7.4
7.8
6.8
7.1
6.1
6.5
5.5
5.8
5.1
5.3
4.5
4.8
4.2
4.4
3.8
4.0
3.5
3.6
3.2
3.3
2.8
2.9
2.6
2.7
2.5
2.6
2.3
2.4
2.1
2.2
1.8
1.8
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
All products are sold to the commercial specifications shown for any additional reliability testing or extended parameters, please consult the factory.
I received this development board a while ago, but I have been away on business and have not been able to test it. Today I finally came back from my business trip, so I will do a simple test. Since it...
What circuit can achieve the output of low level only after the input is converted from high level to low level (or low level to high level), and output high level at all other times?...
{:1_91:}I was woken up by a phone call before I got out of bed, but the call ended before I could answer it{:1_98:}. I dropped my phone and went back to sleep. Then the call came again: "The Jingdong ...
[font=微软雅黑][size=4][color=#0000ff]During the TI WEBENCH promotion, a few netizens generated a large number of WEBENCH designs in a very short period of time. This number of designs has completely exce...
Microwave linear power amplifiers are becoming more and more important in modern microwave (wireless) communication systems. In particular, in CDMA mobile communication systems, linear power amplifier...
1. Introduction
RFID (radio frequency identification) is a non-contact automatic identification technology that emerged in the 1990s. It uses the characteristics of radio frequency signal prop...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
Electronic systems are located at different points on the automotive power bus and therefore often need to operate under very stringent power requirements. These include load dump, cold crank, very lo...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
1. Introduction
Testing the temperature of steel billets before rolling is an important measure to ensure the quality of steel. Traditional manual testing is difficult to ensure product qu...[Details]
With the advocacy and implementation of the government's Safe City Plan, the security market has increasingly higher requirements for the clarity of surveillance images. Imagine that after a case o...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
Continuity test
A variety of devices need to be checked for continuity, including cable assemblies, printed circuit boards, and connectors to ensure that these components have the expected contin...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
Abstract: The output of high-range acceleration sensor is less than 10 mV under the excitation of small signal. The noise of traditional test system may cover such small voltage signal, so that hig...[Details]
The rectified DC voltage is then converted back to AC using power electronics such as insulated gate bipolar transistors.
The output voltage is switched on and off at a high frequency, control...[Details]
1 Battery technology determines the fate of energy vehicles
Regardless of whether new energy vehicles are hybrid or pure electric vehicles, they cannot do without the core technology of batter...[Details]
Multimedia processors are often the most power-hungry devices in portable electronic devices. Common ways to reduce CPU power requirements are to reduce clock frequency or operating voltage, but th...[Details]
introduction
The core features of mobile value-added service products are mobility, immediacy and personalization. Mobile value-added services are a new service mode that is rapidly developing...[Details]