Part Number

Search

TB300-22L4QC8

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 2 ROWS, 1 DECK
CategoryThe connector    terminals   
File Size348KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

TB300-22L4QC8 Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 2 ROWS, 1 DECK

TB300-22L4QC8 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Other features94V-0
Fastening methodSCREW
Manufacturer's serial numberTB300
Number of layers1
Rows2
Number of channels44
Rated current30 A
Rated voltage600 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
INDEX
Series TB300 & TB345
Double Row Terminal Blocks
SPECIFICATIONS
Rating: TB300 – 30A, 600V*
TB345 – 45A, 600V*
Center Spacing: .562” or 9/16” (14.28 mm)
Wire Size: #10 - 22 AWG CU
Screw Size: TB300 – #8-32 philslot screws
TB345 – #10-32 philslot screws
Torque Rating: #8 screws - 16 in-lb.;
#10 screws - 20 in-lb.
Distance Between Barriers: .41” (10.5 mm)
Mounting: TB300 – #8 screws; TB345 – #10 screws
Material: Molded base: Black, UL rated 94VO thermoplastic
Terminal plating: Tin over brass; Screws: Zinc plated steel
Operating Temperature: 130°C (260°F) max., -40°C (-40°F) min.
Breakdown Voltage: 7500V rms
Approvals: UL E62622; CSA LR15364; IEC Compliance;
CE Certified
* Max. rating shown; some options may be rated lower - consult factory.
TB300-08
TB345-06SP
Poles
02
03
04
05
06
07
08
09
A
2.13
2.69
3.25
3.81
4.37
4.94
5.50
6.06
B
1.69
2.25
2.81
3.37
3.94
4.50
5.06
5.62
Poles
10
11
12
13
14
15
16
17
A
B
Poles
18
19
20
21
22
23
24
A
11.12
11.68
12.24
12.80
13.37
13.93
14.49
B
10.68
11.25
11.81
12.37
12.93
13.50
14.06
TB300 & TB345
Inches (mm)
8-32 binding head scre w - TB 300
10-32 binding head scre w - TB 345
A
.22
(5.6)
B
6.62 6.19
7.18 6.75
7.75 7.31
8.31 7.87
8.87 8.44
9.43 9.00
9.99 9.56
10.56 10.12
.50 (12.7)
.90
1.33
(22.8) (33.8)
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
.56
(14.2)
.21dia.
(5.3)
.56
(14.2)
.412
(10.4)
.21 x .25 slots
(5.3 x 6.3)
.33 (8.4)
.81
(20.5)
Part Numbering System
Series
T B 3
nnnnn
300 - 8/32 screw
345 - 10/32 screw
-
Poles
Screw Options
Marking
Hardware Options
nn
02 to 24
nn
Blank - std. screws
00 - screws shipped bulk
B - brass philslot, nickel plated
BS - brass Sems philslot, zinc plated
(TB300 only)
SP - steel Sems philslot, zinc plated
ST - stainless steel, pnilslot
nn
L1 to L6 - std. marking
Marker strips (pg 33)
Covers (pg 32)
nnnn
QC1 to QC20 - quick connects
(TB300 only)
Cooper Bussmann
l
7300 W. Wilson Ave
l
Chicago, IL 60656-4708
l
Fax: 708-867-2211
l
Phone: 708-867-4600
Website: http://www.busscc.com
29
【Open1081】What is the function of bootloader for the new stm32F205 series?
While getting familiar with Open1081, I have a question. The STM32F205 flash partition diagram is shown in Figure , which are bootloader, parameter, mxchipWnetTM firmware and RF driver. I don't know t...
ycdhonker RF/Wirelessly
[RVB2601 Creative Application Development] Study Notes 1 - Development Environment Construction and New Project
1. IntroductionJianchi CDK is an integrated development environment launched by Pingtou Ge that is professional for IoT development. This integrated development environmentis based on Pingtou Ge's 152...
zhengyad XuanTie RISC-V Activity Zone
When TINA simulates, if the input voltage is increased, an error message is displayed: No operating point found
[i=s] This post was last edited by paulhyde on 2014-9-15 03:13 [/i] When I increase the input voltage during TINA simulation, I keep getting the error message: No operating point found. Why is this ha...
W054249 Electronics Design Contest
About OEMAddressTable/g_oalAddressTable and the complete analysis of config.bib - a bunch of weak questions, give points!
Now using S3C2440, it is still a bit difficult to understand OEMAddressTable and config.bib together. The path of OEMAddressTable (pre-CE 5.0) is generally: %WINCEROOT%\PLATFORM\\KERNEL\HAL\ARM in the...
kelvinyung Embedded System
<Boiled Three Kingdoms>
Easy-to-understand stories teach us a lot of management knowledge. Good book!...
winnerlanbest Embedded System
Urgent! Please help me, serial communication problem
Hello everyone! I want to use VC to implement a serial port forwarding function, that is, if there is data coming from serial port 1, it will be forwarded to serial port 2, and if there is data coming...
jjphero Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 902  1294  490  1957  1595  19  27  10  40  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号