EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-J2WIM

Description
DC-DC Converters 25 to 100 Watts
File Size26KB,2 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

VI-J2WIM Overview

DC-DC Converters 25 to 100 Watts

12
1-800-735-6200
VI-J00
MiniMod
DC-DC Converters
25 to 100 Watts
Features
s
s
s
s
s
s
s
s
s
s
Up to 50W/Cubic Inch
UL, CSA, TÜV, VDE, BABT
CE Marked
Up to 90% Efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote Sense and Current Limit
Logic Disable
Wide Range Output Adjust
ZCS Power Architecture
Low Noise FM Control
Nominal
0 =
1 =
W=
2 =
3 =
N =
4 =
T =
5 =
6 =
7 =
Rev 3 1 of 2
Converter Selection Chart
VI-J
Input Voltage
Range
Brownout
/
Transient
*
22V
36V
n/a
60V
72V
n/a
110V
n/a
215V
425V
n/a
12V
10 - 20V(5) n/a
24V
21 - 32V(2) 18V
24V
18 - 36V(2) n/a
36V
21 - 56V(6) 18V
48V
42 - 60V(3) 36V
48V
36 - 76V(2) n/a
72V
55 - 100V(2) 45V
110V
66 - 160V(2) n/a
150V
100 - 200V(2) 85V
300V
200 - 400V(3) 170V
150/300V 100 - 375V(6) 90V
Output Voltage
Z =
2V
Y = 3.3V
0 =
5V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2
N
3
L
J
K
4
H
F
D
B
= 15V
= 18.5V
= 24V
= 28V
= 36V
= 40V
= 48V
= 52V
= 72V
= 85V
= 95V
Product Highlights
The VI-J00 MiniMod family establishes
a new standard in component-level
DC-DC converters. This “junior” size
complement to the higher power VI-200
family offers up to 100W of isolated and
regulated power in a board mounted
package. At one-half the size and twice
the power density of previous 100W
modules, and with a maximum operating
temperature rating of 100˚C, the MiniMod
opens new horizons for board-mounted
(distributed) power architectures.
Utilizing Vicor’s “zero-current-
switching” forward converter technology,
proven by an installed base of over
8 million units, the MiniMod family
combines state of the art power density
with the efficiency, low noise and
reliability required by next generation
power systems.
Product Grade/
Operating Temp.
E =
C =
I =
M=
-10°C
-25°C
-40°C
-55°C
to
to
to
to
+100°C
+100°C
+100°C
+100°C
Product Grade/
Storage Temp.
E
C
I
M
=
=
=
=
-20°C
-40°C
-55°C
-65°C
to +105°C
to +105°C
to +105°C
to +105°C
Z
Y
X
W
Output Power/Current
V
OUT
5V
=
25W
=
50W
=
75W
= 100W
Z
Y
X
W
V
OUT
< 5V
=
5A
=
10A
=
15A
=
20A
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(1)
50W
50W
10A
(2)
75W
100W
20A
(3)
100W
100W
20A
*Brownout 75% of rated load; transient voltage for 1 second.
Max. Output For 5V Outputs > 5V Outputs < 5V Outputs
(4)
75W
75W
15A
(5)
50W
75W
15A
(6)
50W
75W
10A
Mechanical Drawing
.49
(12,4)
.30±.015
(7,6)±(0,38)
.65
(16,5)
2.28
(57,9)
1.30
(33,0)
.080 Dia (2) places
Solder plate
over copper alloy
Pin #
1
4
3
2.10
(53,4)
2
9
8
2
3
1.40
1.00 (35,6)
(25,4)
4
5
6
.35± .015
(8,9)±(0,38)
7
8
9
.15
(3,8)
FULL R
.15
(3,8)
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
Product ID
this surface
.22
(5,6) Min.
.30
(7,6) Min.
Function
+In
Gate In
Gate Out
-In
+Out
+Sense
Trim
–Sense
–Out
VI-J00
7
6
5
.70
.40 (17,8)
(10,2)
Packaging Options
SlimMods™, high power density,
flangeless packages and FinMods™,
featuring integral finned heatsinks.
SlimMod:
Option suffix:
- S
Example: VI - JXX - XX
- S
FinMod:
Option suffix:
- F1
and
- F2
Examples:
VI - JXX - XX -F1, 0.75" height
VI - JXX - XX -F2, 1.00" height
.12
(3,0)
1
2.40
(61,0)
1.75
(44,4) Max.
1.90
(48,3)
.50
(12,7)
+.030 (0,76)
-.000 (0)
.01
Aluminum Base
For the latest Vicor Product Information: www.vicorpower.com
Analysis of basic terms of monitoring system
Vertical Sync, Color Video Composite Sync, External Sync, DC Line Lock and Full Sync are different methods of synchronizing cameras. Full Sync Full Lock is the best method of fully synchronizing two c...
moshaoj Industrial Control Electronics
Implementation of FPGA Configuration from Serial in Embedded System Based on ARM
[b]1 Introduction[/b] ARM (Advanced RISC Machines) can be considered a company. It can also be considered a general term for a type of microprocessor, or a technology. Microprocessor applications base...
呱呱 ARM Technology
Linking issues with VS2005
1>Linking... 1>MSVCRTD.lib(msvcr80d.dll) : error LNK2005: _invalid_parameter already defined in LIBCMT.lib(invarginternal.obj) 1>MSVCRTD.lib(msvcr80d.dll) : error LNK2005: memcpy_s already defined in ...
min_sd Embedded System
Can everyone weld? As a professional drawing
So, is it necessary to learn it?...
一株草 PCB Design
Siemens/Cinterion mc37i/mc52i/mc55i module information
Following TC35i/mc39i/mc55, siemens/cinterion launched mc37i/mc52i/mc55i. As a regular agent of Siemens (agent certificate can be provided), Xinghua Keyi will adhere to its consistent fine style and s...
xefon Embedded System
[Repost] What are the key points to follow in EMC processing?
[align=left][color=rgb(25, 25, 25)][font="]EMC has become a "metaphysics" for many novices in the design of electronic circuit systems. The main reason is that it is easy to say but difficult to deal ...
皇华Ameya360 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1230  2743  1093  741  286  25  56  23  15  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号