EEWORLDEEWORLDEEWORLD

Part Number

Search

DC4CC6LB

Description
Snap Acting/Limit Switch, SPDT, Momentary, 6mm, Solder Terminal, Lever Actuator, Panel Mount,
CategoryMechanical and electronic products    switch   
File Size407KB,3 Pages
ManufacturerThe Cherry Corporation
Download Datasheet Parametric View All

DC4CC6LB Overview

Snap Acting/Limit Switch, SPDT, Momentary, 6mm, Solder Terminal, Lever Actuator, Panel Mount,

DC4CC6LB Parametric

Parameter NameAttribute value
MakerThe Cherry Corporation
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke6 mm
Actuator typeLEVER
body width6.5 mm
body height9 mm
Body length or diameter20 mm
Contact (AC) maximum rated R load3A@250VAC
Maximum contact current (AC)3 A
Maximum contact voltage (AC)250 V
Electrical life6000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberDC
Installation featuresPANEL MOUNT
Maximum operating force0.78 N
Maximum operating temperature120 °C
Minimum operating temperature-40 °C
Maximum pre-travel4.5 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Terminal surfaceSILVER
Termination typeSOLDER
DC Series
Subminiature — Sealed
Features
1. Enclosed switch complying with IP 6K7
2. Silicon-free version available
3. Models available for operating temperatures up to 120°C
4. Rated for currents up to 10 amp at 250VAC
5. Range of auxiliary actuators available (can also be retrofitted)
6. Various contact materials available, depending on application
6
7. Mechanical life: min. 1 x10 operations
8. Wide variety of connection options
Electrical Ratings
Electrical Life at Rated Load
Switch
Series
DC1
DC2
DC3
DC4
EN61058 Rating
UL1054 Rating
According to EN
(Min. Operations)
10,000
10,000
50,000
50,000
According to UL
(Min. Operations)
6,000
6,000
100,000
6,000
6A, 250V~
10(1.5)A, 250V~
0.1A, 250V~
3A, 250V~
5A, 125/250VAC; 1A, 48VDC
10.1A, 125/250VAC; 1/4HP, 125VAC
0.1A, 125/250VAC
3A, 125/250VAC
Electrical Specifications
Temperature Rating
Flammability Rating
-40° to +85°C /+120°C
(without wire leads)
-40° to +85°C / +105°C
(with wire leads)
UL94V-O
(PET, PBT)
UL94HB
(POM)
Material Specifications
Case:
Actuator:
Auxiliary Actuator:
Terminals:
Contacts:
PET / PBT
POM
(T85),
PBT
(T120)
Stainless Steel or Plastic
Silver-Plated Copper-Zinc
Silver Alloy
(DC3 — Gold Crosspoint)
PBT = Polybutyleneterephthalate • PET = Polyethyleneterephthalate • POM = Polyacetal
.
Specifications subject to change without notice.
Single-ended to differential transformer
I need help from industry insiders. I need a single-ended to differential device. Since the input signal frequency is 4GHz bandwidth, I have looked for many differential op amps. The differential op a...
yangyang_l Analog electronics
How Java/.net programmers turn to embedded systems
I have been learning Java and .net for a long time. Now I want to learn embedded systems. I don't know where to start. Can experts give me some advice? Thank you. I know C/C++, can understand assembly...
Sunny2009 Embedded System
Peel off the diamond coat and take a peek at the laser tube in the optical drive
I haven't taken apart anything for a few days and my hands are itching to do something, so I'll take apart something I've never taken apart before! This time I'm working on the laser tube in an optica...
jyl PCB Design
【CN0117】Using the digital potentiometer AD5292 and the operational amplifier ADA4091-4 to build a programmable bidirectional current source
Circuit Function and BenefitsThe circuit uses the AD5292, a digital potentiometer from the digiPOT+ series, the ADA4091-4 quad operational amplifier, and the ADR512 voltage reference to provide a prog...
EEWORLD社区 ADI Reference Circuit
Personal experience: I am a deaf person. Can anyone with experience in embedded development tell me which host is suitable? RAM?
I am a 2008 graduate from Beijing Union University College of Special Education. I am currently studying C and basics of data structures. I am going to attend a weekend class on embedded development n...
xinxi Embedded System
HyperTerminal cannot access the development board
I can't log into the development board using the hyperterminal under XP, and it shows "boot me". What's the reason? I'm a novice, and I hope you can give me some advice!...
zhuxy89 ARM Technology

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2845  2145  1239  811  366  58  44  25  17  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号