EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-2T1EW

Description
DC-DC Converters 50 to 200 Watts
File Size29KB,2 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet View All

VI-2T1EW Overview

DC-DC Converters 50 to 200 Watts

12
1-800-735-6200
VI-200
DC-DC Converters
50 to 200 Watts
Features
s
Up to 50W/Cubic Inch
s
UL, CSA, TÜV, VDE, BABT,
AUSTEL
s
Up to 90% Efficiency
s
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7)
s
Remote Sense and Current Limit
s
OVP, Thermal Shutdown
s
Logic Disable
s
Wide Range Output Adjust
s
Compatible Power Booster Modules
s
ZCS Power Architecture
s
Low Noise FM Control
s
CE Marked
Nominal
0
1
W
2
3
N
4
T
5
6
7
=
12V
=
24V
=
24V
=
36V
=
48V
=
48V
=
72V
=
110V
=
150V
=
300V
= 150/300V
Rev 3 1 of 2
Converter Selection Chart
VI-2
Input Voltage
Range
Brownout
/
Transient
*
10
21
18
21
42
36
55
66
100
200
100
-
-
-
-
-
-
-
-
-
-
-
20V
32V
36V
56V
60V
76V
100V
160V
200V
400V
375V
(1)
(4)
(2)
(3)
(4)
(4)
(4)
(2)
(5)
(4)
(6)
n/a
18V
n/a
18V
36V
n/a
45V
n/a
85V
170V
90V
22V
36V
n/a
60V
72V
n/a
110V
n/a
215V
425V
n/a
Output Voltage
Z =
2V
Y = 3.3V
0 =
5V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
2
N
3
L
J
K
4
H
F
D
B
= 15V
= 18.5V
= 24V
= 28V
= 36V
= 40V
= 48V
= 52V
= 72V
= 85V
= 95V
Product Grade/ Product Grade/
Operating Temp. Storage Temp.
E =
C =
I =
M=
-10°C to
-25°C to
-40°C to
-55°C to
+85°C
+85°C
+85°C
+85°C
E
C
I
M
=
=
=
=
-20°C to +100°C
-40°C to +100°C
-55°C to +100°C
-65°C to +100°C
Output Power/Current
V
OUT
5V
Y
=
50W
X
=
75W
W
= 100W
V
= 150W
U
= 200W
V
OUT
< 5V
Y
=
10A
X
=
15A
W =
20A
V
=
30A
U
=
40A
Product Highlights
The VI-200 Family, with over 8 million
shipped, is Vicor’s first generation of
“zero-current-switching” component-level
DC-DC converters.
Operating at frequencies up to 2 MHz,
VI-200 Family Converters offer
exceptional power density, efficiency,
noise performance, reliability and ease of
use. Power Boosters provide a simple, cost
effective, off-the-shelf solution for higher
power output requirements. One or more
boosters may be used to create synchronous
arrays capable of supplying several
kilowatts of output power.
The flexibility of Vicor’s power components
is also available in half-size, half-power
VI-J00 MiniMods. (pg. 72)
Overtemperature shutdown 95°C typical
(recycle power to restart).
Max. Output For
(1)
(2)
(3)
5V Outputs
75W
150W
100W
> 5V Outputs
75W
150W
100W
< 5V Outputs
15A
30A
20A
For additional output power use “Boosters”.
Change (VI-2xx-xx) to (VI-Bxx-xx).
Max. Output For
(4)
(5)
(6)
5V Outputs
200W
150W
75W
> 5V Outputs
200W
200W
100W
< 5V Outputs
40A
40A
20A
*
Brownout 75% of rated load; transient voltage for 1 second.
Mechanical Drawing
.50
(12,7)
.30±.015
(7,6)±(0,38)
1.80
(45,7)
4.60
(116,8)
3.60
(91,4)
.080 (2,0) Dia (2) places
Solder plate
over copper alloy
4
2.10
(53,3)
3
9
Packaging Options
SlimMods™, high power density,
flangeless packages and FinMods™,
featuring integral finned heatsinks.
SlimMod:
Option suffix:
- S
Example: VI - 2XX - XX
- S
FinMod:
Option suffix:
- F1
and
- F2
Examples:
VI - 2XX - XX -F1, 0.75" height
VI - 2XX - XX -F2, 1.00" height
VI-200
2
1
8
7
6
5
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
.35±.015
(8,9)±(0,38)
Pin #
1
2
3
4
5
6*
7*
8*
9
Function
+In
Gate In
Gate Out
-In
+Out
+Sense
Trim
-Sense
-Out
.15
(3,8)
FULL R
.15
(3,8)
Product ID
this surface
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
* Do not connect on
Booster modules
2.40
(61,0)
4.20
(106,7)
.22
(5,6) MIN
.30
(7,6) Min
1.75
(44,5)
.50
(12,7)
.12
(3,0)
+.030 (0,76)
-.000 (0)
.01
Aluminum Base
70
For the latest Vicor Product Information: www.vicorpower.com
The sub-forum moderator is reporting in!
I came across EEWorld by chance through searching, and I fell in love with it. I unexpectedly won an award in less than half a month in the first month! I am very lucky! Special thanks to sister Soso ...
gaoxiao Suggestions & Announcements
How to test if my MSP430 chip is burnt out?
Now I can't download the program into my MSP430. What might be the problem? And how can I test whether my microcontroller is burnt out based on the fact that I can't download the program now? Urgent.....
duanjuan Microcontroller MCU
What is the range of high frequency in the triode principle?
I would like to ask, in the electronic circuit, the triode working in the high frequency band needs to consider its inter-electrode capacitance. I would like to ask at what Hz does this high frequency...
sunboy25 RF/Wirelessly
Has anyone changed the NandFlash under S3C6400? I changed it from K9F1208 (64MB) to K9F1G08 (128MB). Mine reported ECC error when I downloaded NK and wrote it in.
Has anyone changed the NandFlash under S3C6400? I changed it from K9F1208 (64MB) to K9F1G08 (128MB). Mine reported ECC error when I downloaded NK and wrote it in....
a2479104 Embedded System
How to test sending and receiving of nrf54l01 module separately?
How do I test the NRF24L01 module for sending and receiving separately? If I test the sending mode first, how do I check whether it has sent data?...
jianhong0425 MCU
How to understand this circuit?
How to understand this circuit?...
测控一哥 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1108  408  1323  2536  1360  23  9  27  52  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号