EEWORLDEEWORLDEEWORLD

Part Number

Search

FFKDS/V2-5,08

Description
Barrier Strip Terminal Block
CategoryThe connector    terminals   
File Size115KB,5 Pages
ManufacturerPHOENIX CONTACT
Websitehttps://www.phoenixcontact.com
Environmental Compliance
Download Datasheet Parametric View All

FFKDS/V2-5,08 Overview

Barrier Strip Terminal Block

FFKDS/V2-5,08 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerPHOENIX CONTACT
Reach Compliance Codecompliant
ECCN codeEAR99
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK

FFKDS/V2-5,08 Preview

https://www.phoenixcontact.com/us/products/1790348
PCB terminal block - FFKDS/V2-5,08 - 1790348
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
PCB terminal block, Nominal current: 15 A, Nom. voltage: 320 V, Pitch: 5.08 mm, Number of positions: 1,
Connection method: Push-in spring connection, Mounting: Wave soldering, Conductor/PCB connection direction:
90 °, Color: green, Single module for the custom grouping of different numbers of positions. An end terminal block
is also needed to terminate the block (see accessories). Blocked items with different numbers of positions are
also available.
Why buy this product
 Time saving push-in connection, tools not required
 Defined contact force ensures that contact remains stable over the long term
 Intuitive use through colour coded actuation lever
 Operation and conductor connection from one direction enable integration into front of device
 Two solder pins reduce the mechanical strain on the soldering spots
 The latching on the side enables various numbers of positions to be combined
 Vertical connection enables multi-row arrangement on the PCB
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
4017918044251
1.110 g
85369010
Germany
1 STK
250 STK
Technical data
Dimensions
Length
Pitch
10 mm
5.08 mm
04/06/2017   Page 1 / 5
https://www.phoenixcontact.com/us/products/1790348
PCB terminal block - FFKDS/V2-5,08 - 1790348
Technical data
Dimensions
Width
Constructional height
Height
Solder pin [P]
Pin dimensions
Hole diameter
5.08 mm
16 mm
13.4 mm
3.4 mm
0,5 x 1 mm
1.3 mm
General
Range of articles
Insulating material group
Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Rated voltage (III/3)
Rated voltage (III/2)
Rated voltage (II/2)
Connection in acc. with standard
Nominal current I
N
Nominal cross section
Maximum load current
Insulating material
Solder pin surface
Flammability rating according to UL 94
Stripping length
Number of positions
FFKDS(A)/V2
I
4 kV
4 kV
4 kV
320 V
320 V
630 V
EN-VDE
15 A
1.5 mm²
15 A (with 1.5 mm² conductor cross section)
PA
Sn
V0
10 mm
1
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule without plastic sleeve max.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
Conductor cross section AWG min.
Conductor cross section AWG max.
0.2 mm²
1.5 mm²
0.2 mm²
1.5 mm²
0.25 mm²
0.75 mm²
0.25 mm²
0.75 mm²
24
16
Standards and Regulations
04/06/2017   Page 2 / 5
https://www.phoenixcontact.com/us/products/1790348
PCB terminal block - FFKDS/V2-5,08 - 1790348
Technical data
Standards and Regulations
Connection in acc. with standard
Flammability rating according to UL 94
EN-VDE
CSA
V0
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Drilling diagram
3,5
0,95
Dimensional drawing
10
5,08
1,3
7,62
3,4
15,8
7,62
0,95
3,5
5,08
Approvals
Approvals
Approvals
CSA / UL Recognized / KEMA-KEUR / cUL Recognized / CCA / IECEE CB Scheme / EAC / cULus Recognized
Ex Approvals
Approval details
CSA 
 
mm²/AWG/kcmil
Nominal current IN
B
16
10 A
 http://www.csagroup.org/services/testing-
and-certification/certified-product-listing/
D
16
10 A
 13631
04/06/2017   Page 3 / 5
https://www.phoenixcontact.com/us/products/1790348
PCB terminal block - FFKDS/V2-5,08 - 1790348
Approvals
 
Nominal voltage UN
B
300 V
D
300 V
UL Recognized 
 
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
B
 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
D
22-16
10 A
300 V
 FILE E 60425
22-16
10 A
300 V
KEMA-KEUR 
 
mm²/AWG/kcmil
Nominal voltage UN
 http://www.dekra-certification.com
 
1.5
250 V
 2160724.01
cUL Recognized 
 
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
CCA 
 
mm²/AWG/kcmil
Nominal voltage UN
B
 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
D
22-16
10 A
300 V
 
 
1.5
250 V
 FILE E 60425
22-16
10 A
300 V
 NTR NL-7074
IECEE CB Scheme 
 
mm²/AWG/kcmil
Nominal voltage UN
 
1.5
 http://www.iecee.org/
 NL-25836
250 V
04/06/2017   Page 4 / 5
https://www.phoenixcontact.com/us/products/1790348
PCB terminal block - FFKDS/V2-5,08 - 1790348
Approvals
EAC 
 
 B.01742
cULus Recognized 
 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
 
Phoenix Contact 2017 © - all rights reserved
http://www.phoenixcontact.com
04/06/2017   Page 5 / 5
Problems with restarting under wince
I used the following code to restart, but found that the system seemed to be logged off, and it did not shut down and restart. Where should I modify, or is there another way? #define IOCTL_HAL_REBOOT ...
wanger Embedded System
What are your predictions for the future of the electronics industry?
Let's work together to create a new generation of the electronics industry! Thank you for your participation. You can also contact me to make progress and develop together with me! ! MSN: wangqingtao2...
wangqingtao Power technology
It is found that the value of the ADC register cannot be written
Why do I always encounter some weird problems? After ADC initialization, the values of the ADC registers remain unchanged, which is weird.Look at the picture below:the program has run normally, and th...
ljy771219 stm32/stm8
Transplanting WIFI driver under Android---Reprint
[i=s]This post was last edited by Wince.Android on 2015-5-11 17:28[/i] [p=26, null, left][color=#362e2b][font=Arial]I referred to an article about porting WIFI driver to Android and recorded it down. ...
Wince.Android Embedded System
Should resources be integrated?
The forum is in the stage of development, and perhaps more and more sub-forums will be established one after another. However, there are many essential pillars that this forum needs. Do they need to b...
gaoxiao Microcontroller MCU
[NXP Rapid IoT Review] + NXP Rapid IoT Online IDE Air Quality Test
[i=s] This post was last edited by Feiyangzi at 2019-1-3 13:48 [/i] Following [url=https://bbs.eeworld.com.cn/thread-1065909-1-1.html]https://bbs.eeworld.com.cn/thread-1065909-1-1.html[/url], we will ...
飞扬自我 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2911  2368  470  2098  2594  59  48  10  43  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号