2-Electrode Gas Discharge Tube (GDT)
UN2E5 Series
Description
Gas discharge Tubes (GDT) are classical components for
protecting the installations of the telecommunications. It is
essential that IT and telecommunications systems -with their
high-grade but sensitive electronic circuits - be protected by
arresters. They are thus fitted at the input of the power supply
system together with varistors and at the connection points to
telecommunication lines. They have become equally indispensable
for protecting base stations in mobile telephone systems as well as
extensive cable television (CATV) networks with their repeaters
and distribution systems.
These protective components are also indispensable in other
sectors, In AC power transmission systems, they are often used
with current-limiting varistors, In customer premises equipment
such as DSL modems, WLAN routers, TV sets and cable modems
In air-conditioning equipment, the integral black-box concept offers
graduated protection by combining arresters with varistors, PTC,
diodes and inductor.
UN2E5-XXXLL
UN2E5-XXXL
Schematic Symbol
Features
u
u
u
u
u
u
Non-Radioactive
RoHS compliant
Low insertion loss
Excellent response to fast rising transients
Ultra low capacitance
5KA surge capability tested with 8/20μs
pulse as defined by IEC 61000-4-5
Agency Approvals
AGENCY
AGENCY FILE NUMBER
E341061
Product Characteristics
Materials
Product
Marking
Glow to Arc
Transition
Current
Glow Voltage
Storage and
Operational
Temperature
Weight
Nickel-plated with Tinplated wires
UNION XXXL
XXX
L
-Nominal voltage
-5KA
Applications
u
u
u
u
u
u
u
u
u
u
u
Communication equipment
CATV equipment
Test equipment
Data lines
Power supplies
Telecom SLIC protection
Broadband equipment
ADSL equipment, including ADSL2+
XDSL equipment
Satellite and CATV equipment
Consumer electronics
< 0.5 Amps
~60 Volts
-40 to +90°C
UN2E5-XXXLL
UN2E5-XXXL
~1.0g
~0.85g
SOCAY Electronics Co., Ltd.
Revision
October 18, 2013
www.socay.com
1/4
@SOCAY Electronics Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
2-Electrode Gas Discharge Tube (GDT)
UN2E5 Series
Dimensions
(Unit: mm)
Without wire Devices (UN2E5-XXXL)
Axial Leaded Devices (UN2E5-XXXLL)
Electrical Characteristics
Service Life
DC
Spark-over
Voltage
Maximum Impulse
Spark-over Voltage
Maximum
Capacitance
Arc
Voltage
Nominal
Impulse
Discharge
Current
@8/20μs
±5
times
Max
Impulse
Discharge
Current
@8/20μs
1 time
Nominal
Alternating
Discharge
Current
@50Hz
1 Sec
10 times
@10/1000μs
300 times
Impulse
Life
Part Number
Marking
Minimum
Insulation
Resistance
@100V/S
@100V/μs
@1KV/μs
@1MHz
@1A
UN2E5-75LL
UN2E5-75L
UN2E5-90LL
UN2E5-90L
UN2E5-150LL
UN2E5-150L
UN2E5-230LL
UN2E5-230L
UN2E5-250LL
UN2E5-250L
UN2E5-300LL
UN2E5-300L
UN2E5-350LL
UN2E5-350L
UN2E5-400LL
UN2E5-400L
UN2E5-470LL
UN2E5-470L
UN2E5-600LL
UN2E5-600L
UN2E5-800LL
UN2E5-800L
Notes:
75L
75V±20%
500V
600V
1 GΩ
(at 25V)
1 GΩ
(at 50V)
1 GΩ
(at 50V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1 GΩ
(at 100V)
1.0pF
~15V
5KA
10KA
5A
100A
90L
90V±20%
500V
600V
1.0pF
~15V
5KA
10KA
5A
100A
150L
150V±20%
500V
600V
1.0pF
~20V
5KA
10KA
5A
100A
230L
230V±20%
600V
700V
1.0pF
~20V
5KA
10KA
5A
100A
250L
250V±20%
700V
800V
1.0pF
~20V
5KA
10KA
5A
100A
300L
300V±20%
800V
900V
1.0pF
~20V
5KA
10KA
5A
100A
350L
350V±20%
800V
900V
1.0pF
~20V
5KA
10KA
5A
100A
400L
400V±20%
900V
1000V
1.0pF
~20V
5KA
10KA
5A
100A
470L
470V±20%
900V
1000V
1.0pF
~20V
5KA
10KA
5A
100A
600L
600V±20%
1100V
1200V
1.0pF
~20V
5KA
10KA
5A
100A
800L
800V±20%
1200V
1400V
1.0pF
~20V
5KA
10KA
5A
100A
1). Terms in accordance with ITU-T K.12 and GB/T 9043-2008
2). At delivery AQL 0.65 level
Ⅱ,
DIN ISO 2859
SOCAY Electronics Co., Ltd.
Revision
October 18, 2013
www.socay.com
2/4
@SOCAY Electronics Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
2-Electrode Gas Discharge Tube (GDT)
UN2E5 Series
Electrical Rating
Item
DC Spark-over Voltage
Impulse Spark-over
Voltage
Insulation Resistance
Capacitance
Test Condition / Description
The voltage is measured with a slowly rate of rise dv / dt=100V/s
The maximum impulse spark-over voltage is measured with a rise time of
dv / dt=100V//μs or 1KV/μs
The resistance of gas tube shall be measured each terminal each other terminal,
please see above spec.
The capacitance of gas tube shall be measured each terminal to each other
terminal.
Test frequency :1MHz
The maximum current applying a waveform of 8/20μs that can be applied across
the terminals of the gas tube. One hour after the test is completed, re-testing of the
DC spark-over voltage does not exceed
±30%
of the nominal DC spark-over
voltage. Dwell time between pulses is 3 minutes.
To meet
the specified
value
Nominal Impulse
Discharge Current
Requirement
Nominal Alternating
Discharge Current
Rated RMS value of AC current at 50Hz, 1 sec. 10 times. Intervals: 3min. The DC
spark-over voltage does not exceed
±30%
of the nominal DC spark-over voltage.
8
IR > 10 ohms.
Recommended soldering profile
Wave soldering
Reflow soldering
Soldering profile applied a single process
Soldering Parameters - Hand Soldering
Solder Iron Temperature: 350°C +/-5°C
Heating Time: 5 seconds max.
SOCAY Electronics Co., Ltd.
Revision
October 18, 2013
www.socay.com
3/4
@SOCAY Electronics Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
2-Electrode Gas Discharge Tube (GDT)
UN2E5 Series
Part Numbering
UN2E5
–
XXX L L
L,
No,
with axial wire
without wire
L, 5KA
8/20μs Level
Nominal DC Spark-over Voltage
75 = 75V
350=350V
90 = 90V
470=470V
150 = 150V
600=600V
230 = 230V
800=800V
Series
Packaging Information
Part Number
UN2E5-XXXLL
UN2E5-XXXL
Unit: mm
Description
Quantity
1000
1000
100PCS per Tray, 10 Trays / Inner Carton
100PCS per Tray, 10 Trays / Inner Carton
Tray used in UN2E5-XXXLL
Tray used in UN2E5-XXXL
Cautions and warnings
u
u
u
u
Gas discharge tubes (GDT) must not be operated directly in power supply networks.
Gas discharge tubes (GDT) may become hot in case of longer periods of current stress (danger of burning).
Gas discharge tubes (GDT) may be used only within their specified values. In the event of overload, the head contacts may
fail or the component may be destroyed.