EEWORLDEEWORLDEEWORLD

Part Number

Search

C9204AA

Description
Rotary Coded Switch, 2 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size135KB,2 Pages
ManufacturerBULGIN
Websitehttp://www.bulgin.co.uk/
Environmental Compliance
Download Datasheet Parametric View All

C9204AA Overview

Rotary Coded Switch, 2 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT

C9204AA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerBULGIN
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeSPINDLE
body width18.5 mm
body height32 mm
Body length or diameter32.3 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@28VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)28 V
Manufacturer's serial number9100
Installation featuresPANEL MOUNT
Number of positions2
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDECIMAL
Switch typeROTARY CODED SWITCH
Termination typeQUICK CONNECT
9100 Rotary Switches
16A 250Vac
2 to 6 position rotary
switch
Ratings up to 20A,
277 Vac Non Inductive
Pairs of single pole
change over contacts
Wide choice of
switching circuits
Can be stacked together
In house test:
Approvals and specifications
16(4)A 250Vac T125
16A 400Vac T125
8(8)A 250Vac T125 5E4 (50,000 Operations)
UL CSA 20A Non Ind 277Vac, 250Vac 2hp, 125Vac 1hp
UL 85°C, file no. E45221, CSA file no. LR10990
30A 12V dc
— Indicative rating only
9100 switches are highly versatile with up to 6 positions at 30° intervals
and 6 terminals per switch. For more complex switching (7 positions &
over), contact sales. Two switches may be stacked to give up to 12
terminal switching.
3mm contact gap.
Technical data on pages 4 & 5.
C 9 5 01 D A
TERMINAL SERIES POSITIONS CIRCUIT SPINDLE BODY
TERMINAL
C
SERIES
POSITION
CIRCUIT
9100 switches offer almost infinite
switching options
For this reason it is impractical to show all the
options available.
The table below gives an example of a
5 position switching sequence:
OFF, 1, 1+2, 1+2+3, 1+2+3+4
SPINDLE
A
B
C
N
K
D
T
ø6.05
2
9.2
ø6.0
4.5
A/F
X
Switching
positions
A - Dim. X = 26.0
B - Dim. X = 22.0
C - Dim. X = 10.8
N - Dim. X = 20.0
K - Dim. X = 13.0
6.3 x 0.8
3
Switching
positions
1
A
2
Off
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5
4.65
A/F
X
D - Dim. X = 12.2
T - Dim. X = 18.0
M
ø6.0
15˚
4
5 A.65
/F
rotary
switches
3
B
12.2
4
9
Switching
positions
4
The code
for your chosen circuit will be
allocated by our technicians.
Please contact sales for details.
Use the blank table to plan your switching
up to 6 positions.
P
4.5
A/F
ø6.0
23.0
5
Switching
positions
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6
R
4.5
ø6.0
A/F 12.2 20.1
for 2 gang switching
1
A
2
S
5
4. /F
A
45
˚
ø6.0
10.8
6
Simple circuits may not use all terminals.
Unnecessary terminals may be omitted.
Switching
positions
3
B
4
L
supplied without spindle
64
tel: +44 (0)20 8979 3232 •
Arcolectric
• email: europe@elektron-technology.com
Gaofen Help! After the system is started, the ResidentFlash folder cannot be seen
I use Wince4.2. After the system is up, I cannot see ResidentFlash. I can see the capacity of the flash in the storage manager, and the unallocated capacity is 0. In the partition information, there i...
wmj0402 Embedded System
What RF signal tests require an oscilloscope?
Why should oscilloscopes be used for RF signal testing? The intuitiveness of time domain measurement A big reason for time domain measurement of RF signals is its intuitiveness. For example, in the ex...
凡实测控 Test/Measurement
Why can't CC2650 play happily?
[i=s]This post was last edited by littleshrimp on 2016-12-22 13:42[/i] Previously I only had CC2650STK (SensorTag). I bought a LAUNCHXL2-RM46 and used the XDS110 on the LAUNCHXL2-RM46 to emulate the C...
littleshrimp TI Technology Forum
Unbelievable: the annual output value is only 1,000 yuan~~~~
Only 1,000 kWh of electricity, that is, 1 yuan per kWh, and the annual output value is only 1,000 yuan. There must be something wrong with this number, but how can an article allow people to guess?...
深圳-袁大头 Analog electronics
Recruitment information for multiple positions in foreign companies
Due to business needs, the company is now recruiting for the following positions: We are a small foreign company in Beijing. 1) Algorithm research engineer (8 people) 2) Embedded algorithm software, D...
flyingdsp Recruitment
The authoritative guide to op amps. I sent it wrong just now. I will send it again.
[i=s]This post was last edited by paulhyde on 2014-9-15 03:23[/i]The Definitive Guide to Op Amp, a super awesome book. Sorry, I need a gold coin to download the information....
电子笔小巴 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1226  1158  951  575  1743  25  24  20  12  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号