EEWORLDEEWORLDEEWORLD

Part Number

Search

PB02S-70-1MM5

Description
2A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET
CategoryThe connector    The connector   
File Size272KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance
Download Datasheet Parametric View All

PB02S-70-1MM5 Overview

2A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOLDER, SOCKET

PB02S-70-1MM5 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; CSA; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 115/250VAC
Manufacturer's serial numberPB
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
POWER LINE FILTER
PB Series
STRAIGHT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
50.1
30.3
22.5
40.0
28.5
4-R5
21.6
2-
3.3
40.0
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.9
47.4
41.8
54.0
FEATURES
The PB series, similar to PA and PASP series, offers filters with
IEC connector providing effective equipment protection of
line-to-ground noise up to 15 Amp, 250VAC. The compact
design filter with low leakage current is well suited for
applications that require strict national and international
emission standards. These filters are also available for
Medical application and offer extremely low Leakage current
to comply with UL544, UL2601 and CSA22.2 standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
G
28.3
20.6
31.0
24.0
21.9
4-R2
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
28.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
3.6
51.8
40.9
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
7
uCOS51 transplant experience
I'm going to upload something today, it was written by Yang Yi from the System Integration Development Department of Julong Company....
xingkong911 Real-time operating system RTOS
Power Factor Correction Manual
A book introducing PFC principles and control strategies!...
tonytong Power technology
Analysis on the application scope of city card system
[Abstract] In addition to the payment function for public transportation, the "City Card System" also includes functions such as small-amount consumption payment, automatic parking fee collection appl...
tmily RF/Wirelessly
How to operate STM8's EEPROM? For example, read a certain byte, write a certain byte
I have a headache reading the STM8 documentation. I searched this documentation and that documentation, but I have not found any registers related to EEPROM....
athlon6 stm32/stm8
Recommended English books on basic electronic circuits Part 2: Electronics around us: 36 interesting electronic experiments
[i=s]This post was last edited by tiankai001 on 2014-5-22 23:33[/i] [size=4][color=#333333][font=宋体][b][url=http://item.jd.com/10614577.html]Electronics around us: 36 interesting electronic experiment...
tiankai001 Robotics Development
What is wrong with this program? It seems that I cannot enter this if statement if(HeardData==226 || HeardData==112)
#include//Contains header files related to 51 single-chip microcomputer unsigned char code LedShowData[]= //Define digital tube display data {0x9F,0x25,0x0D,0x99,0x49, //1,2,3,4,5, 0x41,0x1F,0x01,0x19...
加号3 MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1768  2231  2322  2626  2387  36  45  47  53  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号