Modular Terminal Block,

3273898 Parametric

Parameter NameAttribute value
MakerPHOENIX CONTACT
Reach Compliance Codeunknown

3273898 Preview

https://www.phoenixcontact.com/pi/products/3273898
Distribution block - PTFIX 10/12X4-FE - 3273898
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Distribution block, nom. voltage: 450 V, nominal current: 32 A, connection method: Push-in connection, Push-
in connection, number of connections: 13, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 46.3 mm,
height: 21.7 mm, color: black/yellow, mounting type: for snapping onto a DIN rail adapter
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
4055626668215
8 pc
8 pc
Technical data
General
Number of levels
Number of connections
Potentials
Nominal cross section
Nominal cross section feed-in
Color
Insulating material
Flammability rating according to UL 94
Rated surge voltage
Degree of pollution
Overvoltage category
Insulating material group
Maximum load current
Maximum total current
Nominal current I
N
Nominal voltage U
N
1
13
1
4 mm²
10 mm²
black/yellow
PA
V0
6 kV
3
III
I
41 A
63 A
32 A
450 V
10/28/2020   Page 1 / 11
https://www.phoenixcontact.com/pi/products/3273898
Distribution block - PTFIX 10/12X4-FE - 3273898
Technical data
General
Maximum load current
Nominal current I
N
Open side panel
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (storage/transport)
Ambient temperature (assembly)
Ambient temperature (actuation)
Shock protection test specification
Back of the hand protection
Finger protection
Result of thermal test
Proof of thermal characteristics (needle flame) effective duration
Oscillation, broadband noise test result
Test specification, oscillation, broadband noise
Test spectrum
Test frequency
ASD level
Acceleration
Test duration per axis
Test directions
Shock test result
Test specification, shock test
Shock form
Acceleration
Shock duration
Number of shocks per direction
Test directions
Relative insulation material temperature index (Elec., UL 746 B)
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
Static insulating material application in cold
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Smoke gas toxicity NFPA 130 (SMP 800C)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
57 A
57 A
No
-60 °C ... 85 °C
-25 °C ... 55 °C (For a short time, not exceeding 24 h, -60 to +70 °C)
30 % ... 70 %
-5 °C ... 70 °C
-5 °C ... 70 °C
DIN EN 50274 (VDE 0660-514):2002-11
guaranteed
guaranteed
Test passed
30 s
Test passed
DIN EN 50155 (VDE 0115-200):2018-05
Service life test category 2, bogie-mounted
f
1
= 5 Hz to f
2
= 250 Hz
6.12 (m/s ) /Hz
3.12 g
5h
X-, Y- and Z-axis
Test passed
DIN EN 50155 (VDE 0115-200):2018-05
Half-sine
30g
18 ms
3
X-, Y- and Z-axis (pos. and neg.)
130 °C
130 °C
-60 °C
passed
passed
28 MJ/kg
passed
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
10/28/2020   Page 2 / 11
2 2
https://www.phoenixcontact.com/pi/products/3273898
Distribution block - PTFIX 10/12X4-FE - 3273898
Technical data
Dimensions
Width
Length
Height
46.3 mm
28.6 mm
21.7 mm
Connection data
Connection method
Stripping length
Connection in acc. with standard
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Min. AWG conductor cross section, flexible
Max. AWG conductor cross section, flexible
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
Two conductors with the same cross section, flexible, with TWIN
ferrules, with plastic sleeve, minimum
Two conductors with the same cross section, flexible, with TWIN
ferrules, with plastic sleeve, maximum
Connection cross sections directly pluggable
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
Internal cylindrical gage
Connection
Connection method
Stripping length
Connection in acc. with standard
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Push-in connection
10 mm ... 12 mm
IEC 60998-2-2
0.2 mm²
6 mm²
24
10
0.2 mm²
4 mm²
24
12
0.2 mm²
0.2 mm²
4 mm²
0.5 mm²
1 mm²
0.5 mm² 6 mm² 20 10
0.5 mm²
6 mm²
0.75 mm²
0.5 mm²
4 mm²
A4
Feed-in stage
Push-in connection
12 mm ... 14 mm
IEC 60998-2-2
0.5 mm²
10 mm²
20
6
0.5 mm²
10 mm²
10/28/2020   Page 3 / 11
Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
https://www.phoenixcontact.com/pi/products/3273898
Distribution block - PTFIX 10/12X4-FE - 3273898
Technical data
Connection data
Min. AWG conductor cross section, flexible
Max. AWG conductor cross section, flexible
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
Two conductors with the same cross section, flexible, with TWIN
ferrules, with plastic sleeve, minimum
Two conductors with the same cross section, flexible, with TWIN
ferrules, with plastic sleeve, maximum
20
8
0.5 mm²
0.5 mm²
10 mm²
0.5 mm²
4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm²
Standards and Regulations
Connection in acc. with standard
Flammability rating according to UL 94
IEC 60998-2-2
IEC 60998-2-2
V0
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Circuit diagram
10/28/2020   Page 4 / 11
https://www.phoenixcontact.com/pi/products/3273898
Distribution block - PTFIX 10/12X4-FE - 3273898
Classifications
eCl@ss
eCl@ss 10.0.1
eCl@ss 11.0
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
eCl@ss 9.0
27141120
27141120
27141100
27141120
27141120
27141120
ETIM
ETIM 5.0
ETIM 6.0
ETIM 7.0
EC000897
EC000897
EC000897
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / EAC / EAC / cULus Recognized
Ex Approvals
Approval details
CSA 
 
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
B
600 V
57 A
20-8
 http://www.csagroup.org/services-industries/product-listing/
C
600 V
57 A
20-8
 13631
UL Recognized 
 
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
B
 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
600 V
57 A
20-8
 FILE E 60425
600 V
57 A
20-8
10/28/2020   Page 5 / 11
When STM32 meets SDRAM
[i=s]This post was last edited by cruelfox on 2017-2-20 13:57[/i]SDRAM is a type of DRAM (dynamic random access memory), and is the most commonly used large-capacity RAM - commonly known as memory. (H...
cruelfox stm32/stm8
Report
TI's M3 is out, so let's start with stm32...
fangzhh2008 stm32/stm8
I would like to ask about the disabling and enabling of the internal watchdog of LF2407A.
I would like to ask about the problem of disabling and enabling the internal watchdog of LF2407A. In the C language programming of F2407A, there are similar initialization statements, void SystemInit(...
franklu123 Microcontroller MCU
Question about serial to Ethernet conversion
I've been studying RT-Thread programs recently, and I found that Radio and Serial to Ethernet programs are more representative. I looked at the Serial to Ethernet program and found that there are many...
qqwuying Embedded System
The last good book on MSP430
MSP430 Self-study Notes...
ddllxxrr Microcontroller MCU
Why doesn't the IP setting when starting up CEPC work?
After making the boot disk, I modified set NET_IRQ=0 set XXX_XXX=0 //I forgot the name. My network card type is PCI card, so I set them all to 0 set IP=192.168.29.131 //I want to use static IP, but af...
athlon6 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 326  30  2370  2174  2064  7  1  48  44  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号