Four-port Metallic Line Protector
Four-port Metallic Line Protector
The four-port hybrid Single In-line Package (SIP) line protector protects multiple twisted pair
from overcurrent and overvoltage conditions. Based on a SIP, it is equivalent to four
discrete DO-214AA
SIDACtor
devices and four surface mount fuses. Available in surge
current ratings up to 500 A, this four-port SIP line protector is ideal for densely populated
line cards that cannot afford PCB inefficiencies or the use of series power resistors.
F1
Tip
1
2
F2
Tip
4
5
F3
Tip
7
8
F4
Tip
10
11
Z1
Z2
Z3
Z4
Ring
3
Ring
6
Ring
9
Ring
12
Electrical Parameters
Part
Number *
P0080Z_
P0300Z_
P0640Z_
P0720Z_
P0900Z_
P1100Z_
P1300Z_
P1500Z_
P1800Z_
P2300Z_
P2600Z_
P3100Z_
P3500Z_
V
DRM
Volts
6
25
58
65
75
90
120
140
170
190
220
275
320
V
S
Volts
25
40
77
88
98
130
160
180
220
260
300
350
400
V
T
Volts
4
4
4
4
4
4
4
4
4
4
4
4
4
I
DRM
µAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
I
S
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
I
T
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
I
H
mAmps
50
50
150
150
150
150
150
150
150
150
150
150
150
C
O
pF
100
110
50
50
50
40
40
40
30
30
30
30
30
* For individual “ZA,” “ZB,” and “ZC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
• I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
• Listed
SIDACtor
devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• V
DRM
is measured at I
DRM
.
• V
S
is measured at 100 V/µs.
• Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
• Off-state capacitance (C
O
) is measured at 1 MHz with a 2 V bias and is a typical value for “ZA” and “ZB” product. “ZC” capacitance is
approximately 2x the listed value.
• Lower capacitance MC versions may be available. Contact factory for further information.
Surge Ratings
I
PP
2x10 µs
Amps
150
250
500
I
PP
8x20 µs
Amps
150
250
400
I
PP
10x160 µs
Amps
90
150
200
I
PP
10x560 µs
Amps
50
100
150
I
PP
10x1000 µs
Amps
45
80
100
I
TSM
60 Hz
Amps
20
30
50
di/dt
Amps/µs
500
500
500
Series
A
B
C
http://www.littelfuse.com
+1 972-580-7777
2 - 46
SIDACtor
®
© 2004 Littelfuse, Inc.
Data Book and Design Guide
Four-port Metallic Line Protector
Thermal Considerations
Package
SIP
Symbol
T
J
T
S
R
θJA
Parameter
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance: Junction to Ambient
Value
-40 to +150
-65 to +150
90
Unit
°C
°C
°C/W
+I
+I
I
PP
– Peak Pulse Current – %I
PP
t
r
= rise time to peak value
t
d
= decay time to half value
I
I
T
T
I
I
S
S
I
I
H
H
I
I
DRM
DRM
-V
-V
V
T
V
T
V
DRM
V
DRM
V
S
V
S
100
Peak
Value
Waveform = t
r
x t
d
+V
+V
50
Half Value
0
0
t
r
t
d
t – Time (µs)
-I
V-I Characteristics
t
r
x t
d
Pulse Waveform
-I
14
Percent of V
S
Change – %
12
10
8
I
H
I
H
(T
C
= 25 ˚C)
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40 -20 0 20 40 60 80 100 120 140 160
6
4
2
0
-4
-6
-8
25 ˚C
25 ˚C
Ratio of
-40 -20 0 20 40 60 80 100 120 140 160
Case Temperature (T
C
) – ˚C
Junction Temperature (T
J
) – ˚C
Normalized V
S
Change versus Junction Temperature
Normalized DC Holding Current versus Case Temperature
© 2004 Littelfuse, Inc.
SIDACtor
®
Data Book and Design Guide
2 - 47
http://www.littelfuse.com
+1 972-580-7777
Data Sheets