EEWORLDEEWORLDEEWORLD

Part Number

Search

3092-319-2003

Description
Board Connector, 19 Contact(s), 1 Row(s), Male, Right Angle, 0.156 inch Pitch, Solder Terminal, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size173KB,1 Pages
ManufacturerMethode Electronics Inc.
Download Datasheet Parametric View All

3092-319-2003 Overview

Board Connector, 19 Contact(s), 1 Row(s), Male, Right Angle, 0.156 inch Pitch, Solder Terminal, Black Insulator, Receptacle

3092-319-2003 Parametric

Parameter NameAttribute value
MakerMethode Electronics Inc.
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresWITH HOOKS & LOCKING RAMP
Board mount optionsPCB EDGE LOCKING HOOK
subject depth0.45 inch
body length2.958 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedGOLD OVER NICKEL
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact resistance5 mΩ
Contact styleSQ PIN-SKT
Dielectric withstand voltage1500VAC V
maximum insertion force8.896 N
Insulation resistance500000000000 Ω
Insulator colorBLACK
insulator materialGLASS FILLED POLYCARBONATE
Manufacturer's serial number3000
Plug contact pitch0.156 inch
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
PCB contact patternRECTANGULAR
Plating thickness15u inch
Rated current (signal)7 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.156 inch
Terminal pitch3.9624 mm
Termination typeSOLDER
Total number of contacts19
Evacuation force-minimum value.556 N
.156” (3.96mm)
Through Hole Right Angle Connector
3000 SERIES “TERMACON”
PART NUMBER LEGEND
30XX-XXX-XXXX
CONTACT TAIL DIMS (SEE TABLE 2)
CONTACT MATERIAL (SEE NOTE 1)
OPTIONS
2 - HIGH INSERTION FORCE CONTACT
3 - LOW INSERTION FORCE CONTACT
NO. OF POSITONS (SEE TABLE 1)
OPTIONS
0-
1-
3-
6-
7-
8-
WITH LEGS
WITH HOOKS
WITH HOOKS AND LOCKING RAMP
WITH LOCKING RAMP
WITH HOOKS, LOCKING RAMP AND POLARIZING KEY
WITHOUT HOOKS, W/ LOCKING RAMP AND POLARIZING KEY
CONTACT FINISH (SEE NOTE 2)
INSULATOR MATERIAL (SEE NOTE 1)
MATING HEADERS: 3100 SERIES
POLARIZING KEY &
LOCKING RAMP
LEG
HOOK
Connector Products
1700 Hicks Road • Rolling Meadows, IL 60008 USA
Telephone: 847.392.3500 • Fax: 847.392.9404
email: mcpsales@methode.com • Web Page: www.methode.com
TSP distributed control increases test speed and reduces test costs
TSP technology enhances instrument control by allowing users to use standard PC control or create embedded test scripts that execute on the microprocessor within the instrument. By using TSP test scri...
Jack_ma Test/Measurement
Please help look at this program!
#include#pragma vector = PORT1_VECTOR __interrupt void Port_1(void) { volatile unsigned int i; // volatileWhen programming the source code, do not use optimization for this variablefor (i = 0; i30000;...
Hsiang Microcontroller MCU
Orcad Capture CIS automatically numbers after deleting a component, and DRC appears when importing the netlist into Allegro
For example, I drew 10 resistors, numbered R1~R10, and the connections were already drawn in Allegro. Then I deleted R5 in the schematic, renumbered it automatically, and then imported it into the net...
ayu_ag PCB Design
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. Then the heart rate...
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. So how is heart rate detection achieved? What a...
QWE4562009 Discrete Device
ActiveSync installation error
I encountered an error when installing ActiveSync. The error message was "Error writing to file: C:\Program Files\Microsoft ActiveSync\wcesmgr.exe, please verify that you have access to the directory....
han0602 Embedded System
The 2450 board runs fine at 400M, but crashes when playing CMMB TV at 533M???
Dear hardware and software experts, this problem has puzzled me for a long time. Could you please analyze the reason? Can Shuiyan also help analyze it? The problem is this: We use Samsung's S3C2450 pl...
qiaoli Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2213  2354  2743  2446  1115  45  48  56  50  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号