EEWORLDEEWORLDEEWORLD

Part Number

Search

TMP400

Description
400 Watts Medical & ITE Power Adapters
File Size76KB,2 Pages
ManufacturerTRUMPower
Websitehttp://www.trumpower.com/
Download Datasheet Compare View All

TMP400 Overview

400 Watts Medical & ITE Power Adapters

TMP400 Series
TRUMPower
FEATURES
90~264 VAC Universal Input
0.98 Active Power Factor
Efficiency of 85% Minimum
Low Safety Ground Leakage Current
Certified to Medical and ITE Safety Standards
400 Watts Medical & ITE Power Adapters
MODELS LIST
Product No.
TMP400-18
TMP400-24
TMP400-28
TMP400-36
TMP400-48
Output
Voltage
18V
24V
28V
36V
48V
Maximum
Current @
13C F M
22.23A
16.67A
14.29A
11.12A
8.34A
Maximum
Output Pow er
400W
400W
400W
400W
400W
GENERAL SPECIFICATIONS
Power Factor ............................
Efficiency ..................................
Hold-up Time ............................
Switching Frequency ................
Line Regulation ........................
Operating Temperature ...........
Derating ....................................
Storage Temperature ...............
Relative Humidity .....................
Withstand Voltage ....................
0.98 typical @ 115 VAC
85% min. @ 115 VAC or 230 VAC
12ms @ 110 VAC & 400W
85 KHz typical
±0.5% max. at full load
0°C to +60°C
Derate from 100% at +40ºC
linearly to 50% at +60°C
-40°C to +85°C
5% to 95% non-condensing
5,600 VDC from input to output
2,100 VDC from input to ground
700 VDC from output to ground
5,000 meters max.
350K hours minimum at full load,
25°C ambient, calculated per
MIL-HDBK-217F
INPUT SPECIFICATIONS
Input Voltage Range ................. 90~264 VAC
Input Frequency ........................ 47~63Hz
Input Current ............................. 4.2A rms @ 115 VAC, 60 Hz
2.1A rms @ 230 VAC, 50 Hz
Inrush Current .......................... 20A @ 115 VAC or 40A
@ 230 VAC, at 25°C cold start
Earth Leakage Current ............. 300µA max. @ 264 VAC, 63 Hz
Touch Current ........................... 100µA max. @264 VAC, 63 Hz
Operating Altitude .....................
MTBF .........................................
STANDARDS & COMPLIANCES
EN 55011/EN 55022 ........... Class B, conducted & radiated
FCC ...................................... Class B, conducted & radiated
VCCI ..................................... Class B, conducted & radiated
EN 61000-3-2 ...................... Harmonic distortion, Class B & D
EN 61000-3-3 ...................... Line flicker
EN 61000-4-2 ...................... ESD, ±8 KV air and ±6 KV contact
EN 61000-4-3 ...................... Radiated immunity, 3V/m
EN 61000-4-4 ...................... Fast transient/burst, ±2 KV
EN 61000-4-5 ...................... Surge, ±1 KV diff., ±2 KV com.
EN 61000-4-6 ...................... Conducted immunity, 3 Vrms
EN 61000-4-8 ...................... Magnetic field immunity, 3A/m
EN 61000-4-11 .................... Voltage dips,
30% reduction for 500ms,
60% reduction for 100ms,
>95% reduction for 10ms
Safety Standards ................. IEC/EN/UL 60601-1 3rd Ed.
.............................................
ANSI/AAMI ES 60601-1:2005
.............................................
CSA C22.2 No. 60601-1:08
.............................................
IEC/EN 60950-1 2nd Ed.
Agency Approvals ................ UL, cUL, TUV, CE, CB
Other Compliances ............ RoHS, CEC & Energy Star Level V
OUTPUT SPECIFICATIONS
Output Power Ratings .............. See table
Minimum Load ......................... Not required
Tolerance .................................. ±5%
Ripple and Noise* .................... 1% peak to peak max. at full load
Overvoltage Protection ............. Set at 115-140% of its nominal
output voltage
Overcurrent Protection ............. Protected to short-circuit
conditions
Thermal Shutdown ................... Protected to over temperature
conditions
Temperature Coefficient .......... ±0.04%/°C max.
Transient Response ................ Max. excursion of 4% or better
on all models, recovering to 1%
of final value within 500 us after
a 25% step load change
* Measured with 20MHz bandwidth at rated line voltage and output load ranges, with
a 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor in parallel
across the output.
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA
408-988-6616
sales@trumpower.com • www.TRUMPower.com

TMP400 Related Products

TMP400 TMP400-18 TMP400-24 TMP400-28 TMP400-48 TMP400-36
Description 400 Watts Medical & ITE Power Adapters 400 Watts Medical & ITE Power Adapters 400 Watts Medical & ITE Power Adapters 400 Watts Medical & ITE Power Adapters 400 Watts Medical & ITE Power Adapters 400 Watts Medical & ITE Power Adapters
Can wireless control modules from different manufacturers be used interchangeably?
[color=#333333] Nowadays, the use of wireless remote control modules is becoming more and more common. The use of wireless remote control modules has brought great convenience to our industrial sites ...
dwzt Robotics Development
Passed and failed
May I ask the administrator which rule this post violates?...
sanhuasr Suggestions & Announcements
Has anyone used Quickwave?
Has anyone used Quickwave? What are the features of this software compared with CST and Feko?...
oolv RF/Wirelessly
The weather is unusual this year. How is the weather where you are now?
Let me first talk about the weather here right now.Location: Fuzhou countryside Weather: Rainy day Temperature: 16-22 degrees今年天气真的是很反常,三月末四月初的时候热的穿短袖。五月却是长袖加外套。有那么几天我甚至在穿棉袄,那个冷啊冷。 长这么大六一一直都是穿着短袖过的,除了...
okhxyyo Talking
When laying out a PCB, for example, if the wiring of a resistor cannot be routed away, can the wiring be routed between the two pad terminals of the resistor?
When laying out a PCB, for example, if a resistor cannot be routed away, can the wire be routed between the two pad terminals of the resistor? Is there any harm in doing so?...
小太阳yy Analog electronics
Problems encountered in the three-phase PFC project, please help me
Using TMS320X28121. The algorithm is voltage outer loop and current inner loop control (both are PI control), svpwm algorithm I don't understand why phase compensation is needed. How are the above thr...
li4850729 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 92  304  184  2248  2287  2  7  4  46  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号