MCC
Micro Commercial Components
TM
omponents
20736 Marilla
Street Chatsworth
!"#
$
% !"#
S3A
THRU
S3M
3 Amp
Silicon Rectifier
50 to 1000 Volts
DO-214AB
(SMC)
G
•
Features
•
•
•
•
•
•
•
•
•
•
Lead Free Finish/Rohs Compliant (Note1) ("P"Suffix designates
Compliant. See ordering information)
For Surface Mount Applications
Low Thermal Resistance
High Current Capability
High Temp Soldering: 260°C for 10 Seconds At Terminals
Epoxy meets UL 94 V-0 flammability rating
Moisture Sensitivity Level 1
Halogen
free available upon request by adding suffix "-HF"
Maximum Ratings
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 10°C/W Junction To Lead
MCC
Part
Number
S3A
S3B
S3D
S3G
S3J
S3K
S3M
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
DIM
A
B
C
D
E
F
G
H
Device
Marking
S3A
S3B
S3D
S3G
S3J
S3K
S3M
H
D
C
A
E
B
F
DIMENSIONS
INCHES
MIN
.079
.108
.002
.006
.030
..305
.260
.220
MM
MIN
2.00
2.75
0.051
0.152
0.76
7.75
6.60
5.59
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
I
F(AV)
3.0A
T
a
= 120°C
Current
Peak Forward Surge
I
FSM
100A
8.3ms, half sine
Current
Maximum
V
F
I
FM
= 3.0A;
Instantaneous
1.20V
Forward Voltage
T
J
= 25°C*
Maximum DC
I
R
Reverse Current At
T
J
= 25°C
10µA
Rated DC Blocking
250µA T
J
= 125°C
Voltage
Typical Junction
C
J
60pF
Measured at
Capacitance
1.0MHz, V
R
=4.0V
*Pulse test: Pulse width 200
µsec,
Duty cycle 2%
Note:
1.
High Temperature Solder Exemptions Applied, see EU Directive Annex 7.
MAX
.103
.128
.008
.012
.060
.320
.280
.245
MAX
2.62
3.25
0.203
0.305
1.52
8.13
7.11
6.22
NOTE
SUGGESTED SOLDER
PAD LAYOUT
0.190
0.125”
0.070”
Revision: C
www.mccsemi.com
1 of 4
2014/03/07
S3A thru S3M
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
25°C
Amps
1
.5
.6
.4
.2
.1
.06
.04
.02
.01
.5
.7
.9
1.1
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
1.3
1.5
1.7
0
1.5
Amps
1.0
2.5
3.0
MCC
TM
Micro Commercial Components
Figure 2
Forward Derating Curve
2.0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
40
60
80
100
°C
120
140
160
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°C
100
60
40
20
pF
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
1000
T
J
=25°C
Junction Capacitance - pF
versus
Reverse Voltage - Volts
Revision: C
www.mccsemi.com
2 of 4
2014/03/07
S3A thru S3M
MCC
Micro Commercial Components
Figure 5
Peak Forward Surge Current
150
125
100
75
TM
Figure 4
Typical Reverse Characteristics
1000
600
400
200
100
60
40
20
µAmps
10
6
4
2
1
.6
.4
.2
.1
20
40
T
A
=25°C
60
80
Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
140
T
A
=125°C
25
0
1
2
4
6
8 10
Cycles
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
20
40
60 80 100
Amps
50
100
12
0
Revision: C
www.mccsemi.com
3 of 4
2014/03/07
MCC
Micro Commercial Components
TM
Ordering Information :
Device
Part Number-TP
Note : Adding "-HF" suffix for halogen free, eg. Part Number-TP-HF
Packing
Tape&Reel:
3Kpcs/Reel
***IMPORTANT NOTICE***
Micro Commercial Components Corp.
reserves the right to make changes without further notice to any product herein to
make corrections, modifications , enhancements , improvements , or other changes .
Micro Commercial Components
Corp .
does not assume any liability arising out of the application or use of any product described herein; neither does it
convey any license under its patent rights ,nor the rights of others . The user of products in such applications shall assume all
risks of such use and will agree to hold
Micro Commercial Components Corp .
and all the companies whose products are
represented on our website, harmless against all damages.
***LIFE SUPPORT***
MCC's products are not authorized for use as critical components in life support devices or systems without the express written
approval of Micro Commercial Components Corporation.
***CUSTOMER AWARENESS***
Counterfeiting of semiconductor parts is a growing problem in the industry. Micro Commercial Components (MCC) is taking
strong measures to protect ourselves and our customers from the proliferation of counterfeit parts. MCC strongly encourages
customers to purchase MCC parts either directly from MCC or from Authorized MCC Distributors who are listed by country on
our web page cited
below.
Products customers buy either from MCC directly or from Authorized MCC Distributors are genuine
parts, have full traceability, meet MCC's quality standards for handling and storage.
MCC will not provide any warranty
coverage or other assistance for parts bought from Unauthorized Sources.
MCC is committed to combat this global
problem and encourage our customers to do their part in stopping this practice by buying direct or from authorized
distributors.
www.mccsemi.com
Revision: C
4 of 4
2014/03/07