EEWORLDEEWORLDEEWORLD

Part Number

Search

PBA50F_14

Description
AC-DC Power Supplies Enclosed type
File Size565KB,14 Pages
ManufacturerRSG Electronic Components GmbH
Websitehttp://www.rsg-electronic.de/de/
Download Datasheet View All

PBA50F_14 Overview

AC-DC Power Supplies Enclosed type

AC-DC Power Supplies Enclosed type
Ordering information
PBA10F
PBA/PBW
R
PB
1
2
A
3
10
4
F
5
-O
6
-O
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1Series
name
2Single
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
*5
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is acquired)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA10F-5
10
5V 2A
PBA10F-12
10.8
12V 0.9A
PBA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%]
PBA10F-5
PBA10F-12
PBA10F-24
AC85 - 264 1
f
or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
3)
ACIN 100V
0.30typ (Io=100%)
ACIN 200V
0.20typ (Io=100%)
50/60 (47 - 440) or DC
74typ
76typ
77typ
74typ
76typ
77typ
15typ (Io=100%)
30typ (Io=100%)
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
5
12
24
2
0.9
0.5
20max
48max
96max
40max
100max
150max
80max
120max
120max
140max
160max
160max
120max
150max
150max
160max
180max
180max
50max
120max
240max
60max
150max
290max
20max
48max
96max
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
4.50 - 5.50
10.0 - 13.2
19.2 - 27.0
5.00 - 5.15
12.00 - 12.48
24.00 - 24.96
Works over 105% of rated current and recovers automatically
5.75 - 7.00
15.0 - 18.0
30.0 - 37.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
-10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter
*
4)
*
7
31
X
78
X
68mm [1.22
X
3.07
X
2.68 inches] (without terminal block) (W
X
H
X
D) / 150g max (without cover)
Convection
*5
*6
*7
*
*
*
Please contact us about safety approvals for the model with option.
Please contact us about dynamic load and input response.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
*
6
LOAD REGULATION[mV]
*
6
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
*1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Derating is required.
*4
When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
PBA/PBW-2
AM3359 ICE development board running powerlink on Linux
Hi, I have a TI AM3359 ICE development board. I have completed the Linux system porting. I want to run the Powerlink protocol on Linux. However, the network implementation of this board does not suppo...
simonls Linux and Android
V853 Replace the startup LOGO
# The overview mainly describes how to replace the startup LOGO of V853 # Environmental software: V853 Tina 5.0 SDK Hardware: Allwinner V853 development board # Specific steps First, let's take a look...
aleksib Domestic Chip Exchange
Dear big brothers, please help me
module flash_mod(clk,rst,LED_OUT); input clk; inout rst; outputLED_OUT; //----------------------// reg [19:0]cnt; reg led_out; parameter T50ms=20'd999_999; //-------------------------// //------------...
xander_wang FPGA/CPLD
The problem of the servo not rotating when the nodemcu esp8266 development board drives it
[i=s]This post was last edited by xiguabuda on 2022-3-11 22:59[/i]I'm new to this. I'm using a development board and MicroPython to drive the servo, but there's no response. Could you please help me f...
xiguabuda MicroPython Open Source section
Mentor Usage Problems
Dear experts, after installing Mentor DC7.9.2, when Capture Design calls the component library, it cannot be displayed, but the component library can be opened separately. Is there any problem with th...
随风飘啊 PCB Design
Ask about the interrupt response speed
Hello everyone, I have been busy with the WM project recently and have not been online for a long time. I encountered a problem today and I would like to ask you for help. I hope you can give me some ...
huzhiming Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 335  597  1611  2531  1128  7  13  33  51  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号