CV01L-A1BP-150.000A

Description
HCMOS/TTL Output Clock Oscillator, 150MHz Nom, ROHS COMPLIANT PACKAGE-14/4
CategoryPassive components    oscillator   
File Size688KB,1 Pages
ManufacturerCardinal Components
Environmental Compliance  
Download Datasheet Parametric View All

CV01L-A1BP-150.000A Overview

HCMOS/TTL Output Clock Oscillator, 150MHz Nom, ROHS COMPLIANT PACKAGE-14/4

CV01L-A1BP-150.000A Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCardinal Components
package instructionROHS COMPLIANT PACKAGE-14/4
Reach Compliance Codecompliant
Other featuresSYMMETRY 45/55 ALSO AVAILABLE
Maximum control voltage3 V
Minimum control voltage0.3 V
maximum descent time10 ns
Frequency Adjustment - MechanicalNO
frequency stability50%
JESD-609 codee3
linearity20%
Manufacturer's serial numberCV01
Installation featuresTHROUGH HOLE MOUNT
Nominal operating frequency150 MHz
Maximum operating temperature50 °C
Minimum operating temperature-10 °C
Oscillator typeHCMOS/TTL
Output load10 TTL, 15 pF
physical size20.8mm x 13.2mm x 5.08mm
longest rise time10 ns
Maximum supply voltage3.465 V
Minimum supply voltage3.135 V
Nominal supply voltage3.3 V
surface mountNO
maximum symmetry40/60 %
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Thru Hole VCXO
CARDINAL COMPONENTS
• Wide frequency range
• Extended temperature range and tight symmetry available
• Broad range of pullability
Series CV01
Part Numbering Example: CV01 L - A3 B3 - 15.360 A P
CV01
SERIES
CV01
L
VOLTAGE
Blank =
5.0V
L = 3.3V
A3
OPERATING TEMP.
A1=-10°C ~ +50°C
A2=-10°C ~ +60°C
A3=-30°C ~ +75°C
A4=-40°C ~ +75°C
A6=-0°C~+70°
B3
STABILITY
B6 = ±100 ppm
BP = ±50 ppm
BR = ±25 ppm
15.360
FREQUENCY
A
TUNING RANGE
A = ±50 ppm
B = ±100 ppm
C = ±150 ppm
D = ±200 ppm
E = ±250 ppm
F = ±300 ppm
G = ±350 ppm
P
LINEARITY
Blank = ±20%
Q
= ±15%
P
= ±10%
Specifications:
Frequency Range:
1.000 MHz to 150.000 MHz
Available Stability Options:
±100 ppm
±50 ppm
±25 ppm
Output Series:
Input Voltage:
Frequency Tuning Range:
TTL/HCMOS
+5.0 VDC ±5%
+3.3 VDC ±5%
±50 ppm
±100 ppm
±150 ppm
±200 ppm
±250 ppm
±300 ppm
±350 ppm
+2.5 VDC ±2.0 VDC (5V)
+1.65 VDC @ ±1.35VDC
±20% Max.
±15% Max.
±10% Max.
Positive
TTL V
OL
=0.4 V Max.
TTL V
OH
=2.4 V Min.
HCMOS V
OL
=10%V
DD
V Max.
HCMOS V
OH
=90%V
DD
V Min.
-0°C to +70°C
-40°C to +85°C
10 TTL
15 pf HCMOS
20 mA (1.000 to 20.000 MHz)
40 mA (20.010 to 50.000 MHz)
50 mA (50.010 to 160.000 MHz)
10 ns
40/60%
45/55%
10 ms
-55°C to +125°C
CVO1
External Control Voltage:
Linearity:
Polarity of Freq. Slope:
Output Voltage:
Operating Temperature
Range Options:
Output Load:
Maximum Input Current:
Maximum Rise/Fall Time:
Duty Cycle:
Max Start-Up Time:
Storage Temperature:
155 Route 46 West
Wayne, NJ 07470
Rev:
V-090414-13
Cardinal Components, Inc.
V-9
TEL:
(973)785-1333
E-MAIL: sales@cardinalxtal.com
WEB: http://www.cardinalxtal.com
【RT-Thread Software Package Application Works】Summary
@I love downloading 【RT-Thread software package application works】+ unpacking and development environment establishment 【RT-Thread software package application works】+ Temperature and humidity control...
okhxyyo Real-time operating system RTOS
How to use printer to print in vxWorks system
In a VxWorks operating system, how to print a text file through a network driver (such as an HP LaserJet 5200 network laser printer)? Can you give some inspiring suggestions?...
zhimuo Real-time operating system RTOS
What solution is used for the toll entrance with license plate recognition? Can someone analyze it? How was the design done?
Every time I enter an underground parking lot, I find that the entrance uses a license plate recognition system, which is pretty good. I want to apply it, but I don’t know how to do it. Can anyone giv...
douxiu MCU
The process of WEBENCH design +220V to 12V regulated power supply
Our company is currently using 220V to directly stabilize the power supply to 12V, so can WEBENCH design it? The answer is yes. Select 220V output 12V on the start interfaceClick to display the recomm...
ddllxxrr Analogue and Mixed Signal
I would like to ask if this is what the selection manual for STM32F103ZET6 means?
There are 4 general timers and 2 advanced timers? I don’t know how to read it, thank you! ! ! !...
electrics stm32/stm8
About the first 4K code booted from nandflash
I now have a program for an LED running light, which is larger than 4K. When S3C2440 starts from nandflash, there is a boot code start.s in front, which is responsible for hardware initialization and ...
chinaklipdas Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 17  997  2492  1020  2197  1  21  51  45  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号