MPM-03
Series
Single Output, 3W
Ultra-Miniature DIP
AC/DC Power Supplies
Key Features:
•
3W Output Power
•
Universal 85-264 VAC Input
•
EN 60950 Approved (UL)
•
Meets IEC Safety Class II
•
Single Regulated Output
•
Meets EN 55022 Class A
•
>300 kHour MTBF
•
Ultra-Miniature “DIP” Case
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Conditions
Min.
Typ.
85
110
47
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Max.
264
370
63
Units
VAC
VDC
Hz
A Pk
Max.
Units
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Temperature Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Note 1
±2.0
±0.5
V
IN
= Min to Max
See Note 3
±1.0
30
230 VAC
50
±0.02
Continuous (Autorecovery)
60
%
%
%
mV
P-P
mSec
%/°C
°C
Units
VAC
M
150
Conditions
Input to Output
500 VDC
Standard
See Note 4
EN 55022
See Note 4
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 5
EN 61000-4-4
See Note 5
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Min.
3,000
100
Min.
Typ.
Max.
General
Parameter
Isolation Voltage
Isolation Resistance
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips
Switching Frequency
Max.
Units
Class A
Class A
Criteria B; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±1 kV /±2 kV
Criteria A; 10 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
100
kHz
Min.
-25
Typ.
+25
Units
°C
°C
°C
%
Typ.
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+70
+95
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Case
Physical
Case Size
Case Material
Weight
1.46 x 0.90 x 0.59 Inches (37.0 x 23.0 x 15.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.70 Oz (20g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 60536 Class II
Max.
Units
kHours
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPM-03S-03
MPM-03S-05
MPM-03S-09
MPM-03S-12
MPM-03S-15
MPM-03S-24
Current
(A)
115
VAC
0.065
0.065
0.065
0.065
0.065
0.065
230
VAC
0.030
0.030
0.030
0.030
0.030
0.030
Output
Voltage
(VDC)
www.micropowerdirect.com
Current
(mA Max.)
Standby
Power
(W, Max)
Efficiency
(%, Typ)
3.3
5.0
9.0
12.0
15.0
24.0
700
600
330
250
200
125
0.25
0.30
0.35
0.35
0.35
0.35
63
72
74
76
76
78
Notes:
1. For the 3.3V output model, Output Accuracy is ±3.0%
2. Operation at no load will not damage the units, however, they may not
meet all specifications.
3. Load regulation is measured for an output change of 10% to 100% at
nominal input line.
4. All units are rated for EN 55022 (CE/RE) class A without external components.
They will meet EN 55022 class B with the addition of the
ACFM-01
(or a
similar discrete filter circuit). Contact the factory for more information.
5. To meet the input surge requirements of EN 61000-4-4 (±2 kV) & EN 61000-4-5
(±1 kV /±2 kV), external components are needed. This can be done discretely,
or with the addition of the
ACFM-01.
Contact the factory for more information.
6. It is recommended that a fuse be used on the input of a power supply for
protection. For the
MPM-03S
series, a 0.5A/250 VAC slow blow should
be used.
Typical Connection
The diagram below illustrates a typical application connection of the
MPM-03S
series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 0.5A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is recommended on the input to protect the unit in the event
of a surge. A 561KD14 or equivalent is recommended.
3. Recommended output filtering capacitors are:
MPM-03S-03
MPM-03S-05
MPM-03S-09
MPM-03S-12
MPM-03S-15
MPM-03S-24
C
1
1.0
µF
1.0
µF
1.0
µF
1.0
µF
1.0
µF
1.0
µF
C
2
150
µF
150
µF
120
µF
120
µF
120
µF
68
µF
C
3
4.7
µF/400V
4.7
µF/400V
4.7
µF/400V
4.7
µF/400V
4.7
µF/400V
4.7
µF/400V
TVS
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
Typical Connection
: With ACFM-01 Input Module (See note 4)
The output filtering capacitor (C
2
) is a high frequency, low resistance electrolytic
capacitor. Capacitor (C
1
) is ceramic. Voltage derating of capacitors should be
80% or above.
4. Input noise and surge suppression modules are available for a number of
MPD
AC/DC power supplies. An
MPM-03S
connection with the ACFM-01 is
illustrated in the diagram at left. For pricing or full technical information on
these modules (ACFM-01 and
ACFM-02)
please contact the factory.
Derating Curve
Mechanical Dimensions
Input Voltage Vs Load
Pin Connections
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.02 (
±
0.50)
Pin
Function
Pin
16
22
26
Function
+V
OUT
+V
CAP
-V
CAP
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
1
AC-Line
3
AC-Neutral
13 No Connection
14
-V
OUT
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
E-Mail: sales@micropowerdirect.com