Part Number

Search

MPU600S12YYEI

Description
MPU-600ESeries
File Size382KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

MPU600S12YYEI Overview

MPU-600ESeries

MPU-600E
Series
Single Output 600W
Power Factor Corrected
AC/DC Power Supplies
Electrical Specifications
Key Features:
Compact 600W Supply
PFC to EN 61000-3-2 “D”
EN 60950 Approved (UL)
CE Certified
FCC Class B Emissions
Universal AC Input
Current Share Option
Compact Case w/End Fan
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Input Undervoltage Protection
Conditions
Universal
Min.
90
47
Typ.
Max.
264
63
Units
VAC
Hz
A
90 VAC
10.0
110 VAC
35
A
220 VAC
70
264 VAC
2.0
mA
Meets EN 61000-3-2 Class D
T10A/250V Fuse
Under 80 VAC ±5 VAC Unit Shuts Down; Unit Recovers Over 86 VAC
Conditions
By Trim Pot
Min.
Typ.
±5.0
±1.0
Max.
Output
Parameter
Output Voltage Adjustment
Output Regulation, See Note 1
Hold Time
Ripple & Noise (20 MHz), See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Units
%
%
mSec
%
ºC
%/ºC
mS
%
%
S
120 VAC, 80% Load
20
See Model Selection Guide
Foldback Circuit, Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
Autorecovery
+85
±0.04
2.5
50% Load Change
5.0
At Turn On/Off
±5.0
230 VAC
1.0
Continuous With Autorecovery
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
General
Parameter
Isolation Voltage, See Note 5
Switching Frequency
Units
VAC
24
kHz
Interface Signals
LED Power Supply On
Current Monitor
Current Share
Remote Sense
Power Good Signal
Bi-color LED Is Green For Power On; Orange When Protection Enabled
A 0.5 to 3.0V Output That Represents 0% to 100% Output Current
Optional For Sharing Up To Four Units. Contact The Factory For Details
Compensates For Up To A 0.5V Line Drop
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation. Will sink 100 mA.
A TTL low signal inhibits the output. Hiccup mode.
Conditions
Min.
Typ.
Max.
Units
Ambient
0
+25
+70
ºC
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
ºC
See Model Selection Guide
RH, Non-condensing
90
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Remote On/Off
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Reliability Specifications
Parameter
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 6100-4-2,3,4,5,6,11; EN 55024, CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s
2
on X, Y & Z Axis
www.micropowerdirect.com

MPU600S12YYEI Related Products

MPU600S12YYEI MPU-600SE MPU600S24YYEI MPU600S48YYEI
Description MPU-600ESeries MPU-600ESeries MPU-600ESeries MPU-600ESeries

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1848  1059  2033  1335  848  38  22  41  27  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号