EEWORLDEEWORLDEEWORLD

Part Number

Search

MA612S15RWI

Description
MA600RWI SERIES
File Size483KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet View All

MA612S15RWI Overview

MA600RWI SERIES

MA600RWI
Series
Wide 2:1 Input, 6W,
High 3 kVDC Isolation
DC/DC Converters
Electrical Specifications
Key Features:
6W Output Power
2:1 Input Voltage Range
3,000 VDC Isolation
24 Standard Models
Single & Dual Outputs
Compact DIP Case
-40°C to +85°C Operation
Industry Standard Pin-Out
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Start Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
12 VDC Input
7.0
24 VDC Input 14.0
48 VDC Input 32.0
12 VDC Input
24 VDC Input
48 VDC Input
(Pi)
Filter
Conditions
Dual Output, Balanced Loads
V
IN
= Min to Max
I
OUT
= 0% to 100%
See Note 1
Over Line, Load & Temp.
25% Load Step Change
Min.
Typ.
8.0
16.0
34.0
Max.
9.0
18.0
36.0
8.5
16.0
35.0
Units
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Typ.
±1.0
±1.0
±0.1
±0.6
Max.
±2.0
±2.0
±0.5
±1.2
70
100
600
±0.02
Units
%
%
%
%
mV P - P
µSec
%
%/°C
%
1.5 kV Isolation
Models
Available
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
300
±3.0
±0.01
Foldback
110
145
Continuous (Autorecovery)
Min.
3,000
1,000
Typ.
General
4:1 Input Range
Models
Available
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Conditions
60 Seconds
500 VDC
100 kHz/1.0V
Max.
1,000
330
Units
VDC
M
pF
kHz
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
See Note 3
See Note 3
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Min.
-40
Typ.
+25
Max.
+85
+100
+125
95
Units
°C
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
-50
Free Air Convection
RH, Non-condensing
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
1.0
Min.
-0.7
-0.7
-0.7
Typ.
Max.
Units
MHours
Units
VDC
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
25.0
50.0
100.0
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Urgently looking for a 0.5us timer solution
I use the STM32103 series, the external is 25M, after the timing is set, it can't come out 0.5us, the fastest is 2us. Please take a look, the code is as followsTIM_TimeBaseInitTypeDef TIM_TimeBaseStru...
yjx356657845 stm32/stm8
A wonderful knot
[align=left][font=微软雅黑][size=4]The rule of PN junction, in the periodic table, P on the left and N on the right, the higher the doping concentration, the smaller the forward resistance and the lower t...
安卓佳 Discrete Device
How to use the single-cell battery charging chip TP4054 with a single-cell fuel gauge chip to achieve accurate power monitoring and reliable charging...
How to use the single-cell battery charging chip TP4054 with the single-cell fuel gauge chip to achieve accurate power monitoring and reliable charging. Generally, fuel gauges do not have charging fun...
QWE4562009 Integrated technical exchanges
Why does romimage.exe report a memory access error when executing ce.bib?
I used romimage.exe ce.bib to generate nk in command line mode. When it came to compacting bin file, it reported that the instruction accessed memory 0x0. However, makeimg was normal in PB. Does anyon...
stforadasen Embedded System
Using STC15 to encounter external interrupt problems
I encountered an external interrupt problem when using STC15. I used external interrupt 1, UART serial port 1, and hardware SPI at the same time. It turned out that the external interrupt can only ent...
doganup MCU
Limitations of Flash_API for C2000 Series (28335) DSP
The API can:1. Run in static internal SARAM2. Configure the correct CPU frequency3. Integrate the API into the application according to the Flash_API list4. Initialize the PLL control register and wai...
Jacktang Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2871  1272  2209  578  737  58  26  45  12  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号