(Reference 900-XC6DT2 for Standby Rating Technical Data)
SYSTEM RATINGS
Prime
Voltage (L-L)
Phase
PF
Hz
kW
kVA
Amps
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
208V**
3
0.8
60
800
1000
2776
2600
741RSL4045
105 °C/40 °C
12 LEAD LOW WYE
240V**
3
0.8
60
800
1000
2406
2600
741RSL4045
105 °C/40 °C
12 LEAD HI DELTA
380V
3
0.8
60
800
1000
1521
1850
740RSL4046
105 °C/40 °C
4 BAR WYE
480V**
3
0.8
60
800
1000
1203
2500
574RSL4037
105 °C/40 °C
12 LEAD HI WYE
600V**
3
0.8
60
800
1000
962
2850
574RSS4280
105 °C/40 °C
4 LEAD WYE
4160V
3
0.8
60
800
1000
139
1950
741FSM4360
105 °C/40 °C
6 LEAD WYE
* Consult the factory for alternate configuration.
** UL 2200 Offered
CERTIFICATIONS AND STANDARDS
//
//
Emissions –
EPA Tier 2 Certified
Generator set is designed and manufactured
in facilities certified to standards ISO 9001:2008 and
ISO 14001:2004
//
Performance Assurance Certification (PAC)
- Generator Set Tested to ISO 8528-5 for Transient Response
- Verified product design, quality and performance integrity
- All engine systems are prototype and factory tested
Power Rating
- Accepts Rated Load in One Step Per NFPA 110
- Permissible average power output during 24 hours of
operation is approved up to 75%.
//
//
UL 2200 / CSA – Optional
– UL 2200 Listed
– CSA Certified
2
/ /
/
/
800-XC6DT2
STANDARD FEATURES*
MTU Onsite Energy is a single source supplier
Global Product Support
2 Year Standard Warranty
16V 2000 Diesel Engine
- 31.8 Liter Displacement
- Electronic Unit Pump Injection
- 4-Cycle
//
Complete Range of Accessories
//
//
//
//
Generator
- Brushless, Rotating Field Generator
- 2/3 Pitch Windings
- PMG (Permanent Magnet Generator) supply to regulator
- 300% Short Circuit Capability
//
Digital Control Panel(s)
- UL Recognized, CSA Certified, NFPA 110
- Complete System Metering
- LCD Display
//
Cooling System
- Integral Set-Mounted
- Engine Driven Fan
//
STANDARD EQUIPMENT*
//
Engine
No Load to Full Load Regulation
Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
105 °C Maximum Prime Temperature Rise
1 Bearing, Sealed
Flexible Coupling
Full Amortisseur Windings
125% Rotor Balancing
3-Phase Voltage Sensing
±0.25% Voltage Regulation
100% of Rated Load - One Step
5% Maximum Total Harmonic Distortion
Air Cleaners
Oil Pump
Oil Drain Extension & S/O Valve
Full Flow Oil Filter
Closed Crankcase Ventilation
Jacket Water Pump
Inter Cooler Water Pump
Thermostats
Blower Fan & Fan Drive
Radiator - Unit Mounted
Electric Starting Motor - 24V
Governor – Electronic Isochronous
Base - Structural Steel
SAE Flywheel & Bell Housing
Charging Alternator - 24V
Battery Box & Cables
Flexible Fuel Connectors
Flexible Exhaust Connection
EPA Certified Engine
//
Digital Control Panel(s)
//
Generator
NEMA MG1, IEEE and ANSI standards compliance for temperature rise
and motor starting
Sustained short circuit current of up to 300% of the rated current for
up to 10 seconds
Self-Ventilated and Drip-Proof
Superior Voltage Waveform
Digital, Solid State, Volts-per-Hertz Regulator
Digital Metering
Engine Parameters
Generator Protection Functions
Engine Protection
CAN Bus ECU Communications
Windows
®
-Based Software
Multilingual Capability
Remote Communications to RDP-110 Remote Annunciator
16 Programmable Contact Inputs
Up to 11 Contact Outputs
UL Recognized, CSA Certified, CE Approved
Event Recording
IP 54 Front Panel Rating with Integrated Gasket
NFPA110 Compatible
* Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional configurations.
3
/ /
/
/
800-XC6DT2
APPLICATION DATA
//
Engine
MTU
16V 2000 G45 TB
4-Cycle
16-V
31.8 (1,943)
13 (5.1)
15 (5.9)
16:1
1,800
Electronic Isochronous (ADEC)
915 (1,227)
±0.25%
Dry
//
Fuel Consumption
PRIME
221.4 (58.5)
169.2 (44.7)
15.4 (30.5)
Manufacturer
Model
Type
Arrangement
Displacement: L (in
3
)
Bore: cm (in)
Stroke: cm (in)
Compression Ratio
Rated RPM
Engine Governor
Maximum Power: kWm (bhp)
Speed Regulation
Air Cleaner
At 100% of Power Rating: L/hr (gal/hr)
At 75% of Power Rating: L/hr (gal/hr)
At 50% of Power Rating: L/hr (gal/hr)
//
Cooling - Radiator System
PRIME
50 (122)
0.12 (0.5)
833 (220)
257 (68)
320 (18,197)
265 (15,070)
92.5 (5,260)
55.6 (74.5)
//
Liquid Capacity (Lubrication)
102 (26.9)
130 (34.3)
20 (5.3)
415 (110)
Total Oil System: L (gal)
Engine Jacket Water Capacity: L (gal)
After Cooler Water Capacity: L (gal)
System Coolant Capacity: L (gal)
Ambient Capacity of Radiator: °C (°F)
Maximum Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: kPa (in. H
2
0)
Water Pump Capacity: L/min (gpm)
After Cooler Pump Capacity: L/min (gpm)
Heat Rejection to Coolant: kW (BTUM)
Heat Rejection to After Cooler: kW (BTUM)
Heat Radiated to Ambient: kW (BTUM)
Fan Power: kW (hp)
//
Air Requirements
PRIME
81 (2,860)
1,133 (40,013)
//
Electrical
24
2,800
Electric Volts DC
Cold Cranking Amps Under -17.8 °C (0 °F)
//
Fuel System
3/4” NPT
1/4” NPT
3 (10)
Diesel #2
480.7 (127)
Aspirating: *m /min (SCFM)
Air Flow Required for Rad.
Cooled Unit: *m
3
/min (SCFM)
Remote Cooled Applications;
Air Flow Required for Dissipation
of Radiated Gen-set Heat for a
Max of 25 °F Rise: *m
3
/min (SCFM)
3
336 (11,863)
Fuel Supply Connection Size
Fuel Return Connection Size
Maximum Fuel Lift: m (ft)
Recommended Fuel
Total Fuel Flow: L/hr (gal/hr)
* Air density = 1.184 kg/m
3
(0.0739 lbm/ft
3
)
//
Exhaust System
PRIME
520 (968)
190 (6,780)
8.5 (34.1)
Gas Temp. (Stack): °C ( °F)
Gas Volume at Stack
Temp: m
3
/min (CFM)
Maximum Allowable
Back Pressure: kPa (in. H
2
0)
4
/ /
/
/
800-XC6DT2
WEIGHTS AND DIMENSIONS
Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website
for unit specific template drawings.
System
OPU
Dimensions (L x W x H)
5,010 x 1,940 x 2,600 mm (197.4 x 76.5 x 102.5 in)
Weight (less tank)
7,733 kg (17,047 lb)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
As shown in the figure, there is usually a 5V voltage input at the arrow position, and the test pin 1 position outputs a low level. Now the problem is that the input at the arrow position is turned of...
The problem is this: I want to call a sound file in pocket pc. But I always get an error "MissingMethodException". I use playsound to call it. [DllImport("winmm.dll")] public static extern bool PlaySo...
[i=s] This post was last edited by Throwing Bricks and Inducing Jade on 2015-10-29 17:26[/i] [font=微软雅黑][size=3]They are all short videos of a few minutes, some are very touching, some are very humoro...
When configuring the CAN message object, there will be settings for node reception filtering g_MsgObject.ulMsgID g_MsgObject.ulMsgIDMask g_MsgObject.ulFlags. For 11-bit IDs, for example, from 0x3F8 to...
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
introduction
Bluetooth technology is a short-range wireless communication technology designed to replace wired cables. It is a wireless communication technology standard developed by the SIG, ...[Details]
Logic analyzers are widely used tools in digital design verification and debugging. They can verify the proper functioning of digital circuits and help users identify and troubleshoot faults. They ...[Details]
For healthcare professionals, accurate diagnosis and treatment are crucial for a clear picture of a person's health. However, healthcare professionals often rely on tests at medical facilities, cli...[Details]
Gross profit margin jumped from 13.6% in the first half of last year to 25.9%, almost doubling year-on-year.
On August 21, RoboSense released its interim performance report, in which the...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
On August 22, South Korean media Nate reported on the 20th local time that Samsung Electronics is introducing Hyper Cell technology into its most advanced 2nm process technology, striving to improv...[Details]
One of the most core components of electric vehicles is the motor. The power supply provides electrical energy to the motor, which converts this electrical energy into mechanical energy, which in t...[Details]
PowiGaN achieves 95% efficiency at both light and full loads, meeting critical operational and safety requirements.
DARWIN, Australia and SAN JOSE, Calif.,
August 22, 2025 – Powe...[Details]
On August 20, Geely announced its focus on "One Cockpit". Through a unified AI OS architecture, a unified AI Agent, and a unified user ID, it will achieve an All-in-One AI cockpit, create the first...[Details]
Over the past decade, the narrative surrounding fuel vehicles has been one of decline and replacement. Under the onslaught of new energy vehicles, traditional automakers have been forced to acceler...[Details]
China, August 21, 2025 – STMicroelectronics (NYSE: STM), a world-leading semiconductor company serving a wide range of electronics applications, has published its IFRS 2025 semi-annual financial re...[Details]
introduction
The rapid adoption of computers has led to a growing number of tasks being performed on them. People from all walks of life, especially programmers and writers, are spending incre...[Details]
introduction
Inverter air conditioners are a trend in the current era and have gradually become commonplace in countless households. Beyond their basic cooling and heating functions, air condi...[Details]
For self-driving cars, LiDAR is the sensory organ that allows them to "see the road." Simply put, its operating principle involves sending out a laser beam, receiving the echo, and ultimately gener...[Details]