EEWORLDEEWORLDEEWORLD

Part Number

Search

IWS1215Y2V

Description
1-OUTPUT 10W DC-DC REG PWR SUPPLY MODULE
CategoryPower/power management    The power supply circuit   
File Size104KB,3 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

IWS1215Y2V Overview

1-OUTPUT 10W DC-DC REG PWR SUPPLY MODULE

IWS1215Y2V Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Reach Compliance Codecompliant
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage18 V
Minimum input voltage9 V
Nominal input voltage12 V
JESD-30 codeR-XDMA-P4
JESD-609 codee0
Number of functions1
Output times1
Number of terminals4
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
Maximum output voltage15.15 V
Minimum output voltage14.85 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output10 W
Fine-tuning/adjustable outputNO
IWS SERIES - 10 WATT
DESCRIPTION
IWS DC/DC converters offer excellent regulation and
isolation in an industry-standard package. Available in
several input versions, the IWS is perfect for industrial,
datacom, or telecom applications. The IWS features short
circuit protection and 500 VDC isolation. Please see the
IWD series for dual-output applications.
FEATURES
• Industry-Standard Package
• Industry-Standard Pinout
• 85°C Case Operation
• Short-Circuit Protection
• 5, 12, 24, and 48V
Input Versions
• Input Pi Filter and
6-Sided Shielding
• Regulated Outputs
• 500V Isolation
Efficiency vs. Load (5V Input)
90
85
EFFICIENCY %
TECHNICAL SPECIFICATIONS
Input
Voltage Range
5 VDC Nominal
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
Reverse Input Current
4.5 - 9 VDC
9 - 18 VDC
18 - 36 VDC
36 - 72 VDC
20% Iin Max.
100% Iin Max.
80
IWS515
IWS548
75
70
10
20
30
40
50
60
70
80
90
100
LOAD %
Efficiency vs. Load (12V Input)
90
85
80
EFFICIENCY %
Output
Setpoint accuracy
Line regulation Vin Min. - Vin Max., Iout Rated
Load regulation Iout Min. - Iout Max., Vin Nom.
Minimum output current
Dynamic regulation, loadstep
Pk deviation
Settling time
Temperature coefficient
Ripple and noise, 20 MHz BW
Short-circuit protection 1
Current Limit
±1%
±0.5% Vout
±1.0% Vout
10 % Iout Rated
25% Iout
1% Vout
500 ms
0.02%/°C
1% Vout Nom.
Continuous
130%
75
70
65
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
-1205
-1212
-1215
General
Switching Frequency
Isolation
Input - Output
500 VDC
500 VDC
500 VDC
109 Ohms
-25 to +85°C
-40 to +85°C
-40 to +125°C
95%
5 g, 10 - 55 Hz
UL, cUL, TUV
1.4 oz
Input - Case
Output - Case
Isolation Resistance - Input to Output
Standard Case Operating Range
Industrial Range (add -I to p/n)
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Safety
Weight (approx.)
300 kHz
Notes
1 Continuous short-circuit protection is provided. Long-term continuous
operation in this mode is not recommended. Converter will auto-restart
once fault has been removed.
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please
consult factory for specific model information.
REV. 12/01
1
I'm posting a new example of CS5532 in STM32. Please help me with it.
No one said anything, so I'll just delete it. [[i] This post was last edited by yanse51 on 2013-1-11 16:46 [/i]]...
yanse51 stm32/stm8
[Repost] Detailed explanation of the failure mechanisms of components
The failure of components is directly affected by factors such as humidity, temperature, voltage, and machinery. 1. Failure caused by temperature: 1.1 Ambient temperature is an important factor leadin...
皇华Ameya360 Power technology
How to stop Downloading files in EVC
a.exe - 0 error(s), 0 warning(s) I want to stop at this step and do not want to proceed to the following steps Downloading files The Microsoft ActiveSync connection server has failed. Please make sure...
瓜妞妞 Embedded System
2016 Infineon Power Management Seminar Tour is now open for registration (June 16th - July 5th)
2016 Infineon "Energy Saving and Efficiency, Create a Better Future" Power Management Tour Seminar is now open for registration! The four-city technology feast is about to start! Register now!Beijing ...
EEWORLD社区 Energy Infrastructure?
Room Monitoring System Based on Bluetooth
In small spaces with high traffic volume such as offices, there are many people and many things going on, so there will always be a series of lost items. Therefore, in order to reduce the occurrence o...
kiroking Wireless Connectivity
What does 酓ummy_isr error, interrupt num:5 ,INTMSK = 0xffffffda mean?
I'm using the external interrupt of 2440. When I press a key, the hyperterminal shows the above information, and then the program stops. What does this mean? Please help me....
ounie Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2744  2851  1381  319  2699  56  58  28  7  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号