EEWORLDEEWORLDEEWORLD

Part Number

Search

CMZ1501-7ERV3AF

Description
DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, METAL, CASE M02, MODULE
CategoryPower/power management    The power supply circuit   
File Size569KB,25 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

CMZ1501-7ERV3AF Overview

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, METAL, CASE M02, MODULE

CMZ1501-7ERV3AF Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE M02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage140 V
Minimum input voltage28 V
Nominal input voltage60 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage16.5 V
Minimum output voltage
Nominal output voltage15 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output50 W
Fine-tuning/adjustable outputYES
Cassette Style
DC-DC Converters
M Series
50 Watt DC-DC (AC-DC) Converters
Wide input voltage from 8...373 V DC
1, 2 or 3 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
• Extremely wide input voltage range suitable for
battery (and AC) operation
• Efficient input filter and built-in surge and transient
suppression circuitry
• Outputs individually isolated and controlled
• Outputs fully protected against overload
Safety according to IEC/EN 60950
LGA
M Series
111
4.37"
3U
Summary
The M series of DC-DC (AC-DC) converters represents a
broad and flexible range of power supplies for use in ad-
vanced industrial electronic systems. Features include high
efficiency, reliability, low output voltage noise and excellent
dynamic response to load/line changes due to individual
regulation of each output.
The converter inputs are protected against surges and tran-
sients occuring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the in-
put voltage is outside the specified range. Certain types in-
clude an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
All outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of built-in suppressor
diodes. The outputs can be inhibited by a logic signal ap-
plied to the connector pin 2 (i). If the inhibit function is not
used pin 2 should be connected to pin 23 to enable the out-
puts.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standard
IEC/EN 60950 and have been approved by the safety
39
1.54"
8 TE
168
6.6"
agencies LGA (Germany) and UL (USA). The UL Mark for
Cana-da has been officially recognized be regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature should remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds the
limit. The outputs are automatically re-enabled when the
temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions ........................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Description of Options .................................................... 19
Accessories .................................................................... 25
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 3
Functional Description ...................................................... 4
Electrical Input Data ......................................................... 5
Electrical Output Data ...................................................... 7
Auxiliary Functions ......................................................... 10
Edition 01/01.2001
1/25
Under the condition of meeting the accuracy requirement, which one is better for measuring inclination, a dual-axis accelerometer or a tri-axis accelerometer?
[font=楷体, 楷体_GB2312][size=4]I would like to ask all the experts passing by, what is the essential difference between measuring inclination with a three-axis accelerometer and measuring inclination wit...
草莓君 ADI Reference Circuit
PSpice simulation, please give me the parameter package library of f/v conversion chip LM331 or AD650, thank you!
PSpice simulation, please give me the parameter package library of f/v conversion chip LM331 or AD650! I can't download it from the official website, and the online resources only have .olb files, but...
18772964987 Analog electronics
Delphi serial communication and engineering practice
An e-book I have been looking for for a long time, download it for free...
LRXTL Microcontroller MCU
Publishing of web pages on WINCE4.0
I would like to ask the experts: I want to publish an interactive web page on WINCE4.0 that can be browsed remotely. The data on the web page comes from the ISA bus of ARM9 and is stored in the memory...
kaixin1 Embedded System
Learn simulation + [Reading notes 2 of "Operational Amplifier Noise Optimization Handbook"] Calm down and read slowly
[i=s]This post was last edited by dontium on 2015-1-23 11:35[/i] The title of the first chapter is Introduction to Statistics and Review. I read this book with a disdainful attitude towards the "Intro...
Sur Analogue and Mixed Signal
Confused, is it Linux or WinCE? ? ? ?
I feel that Linux is very popular in the embedded field, while WinCE is not so popular. I don't know which one is more popular and used in actual applications. What are the advantages of WinCE and Lin...
yutm Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1306  1080  2686  2800  575  27  22  55  57  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号