E
EZIWSON
EZIWSON
Approved
Approved
Prepared (also subject responsible if other)
Prepared (also subject responsible if other)
No.
Ericsson Internal
Ericsson Internal
TABLE OF CONTENTS
PRODUCT SPECIFICATION
001 52 - EN/LZT 146 401 Uen
1/1301-BMR 451 Uen
2011-08-11
Date
Rev
1 (1)
(4)
1
No.
SEC/D (Julia You)
SEC/D (Julia You)
BMR 451 Digital
PoL Regulators
Input
4.5-14
V, Output up to
40
A /
132
W
•
Small package
30.85 x 20 x 8.2 mm (1.215 x 0.787 x 0.323 in.)
•
40 A output current
•
4.5 V – 14 V input voltage range
•
0.6 V – 3.6 V output voltage range (by PMBus)
•
0.7 V – 3.3 V output voltage range (by external resistor)
•
High efficiency, typ. 96,4% at half load, 5 Vin, 3.3 Vout
•
6.9 million hours MTBF
•
Through hole and surface mount versions
•
PMBus read and write compliant
Checked
Checked
Date
Technical Specification
Reference
Rev
Reference
2011-12-21
EN/LZT 146
D
401
R4A
May
2015
E
© Ericsson AB
G
Key Features
General Characteristics
•
•
•
•
•
•
•
•
•
•
•
•
•
Voltage/current/temperature monitoring
Precision delay and ramp-up
Voltage sequencing
Switching frequency synchronization
Configurable control loop
Non-linear transient response
Wide output voltage adjust function
Start up into a pre-biased output
Output short-circuit protection
Over temperature protection
On/Off remote control
Output voltage sense
ISO 9001/14001 certified supplier
Safety Approvals
Design for Environment
Meets requirements in high-
temperature lead-free soldering
processes.
Ordering Information
General Information
Safety Specification
Absolute Maximum Ratings
Functional Specification
Electrical Specification
1.0V, 40A / 40W
3.3V, 40A / 132W
EMC Specification
Operating Information
Thermal Consideration
Connections
Typical Application Circuits
PMbus Interface & Commands
Mechanical Information
Soldering Information
Delivery Information
Product Qualification Specification
Contents
............................................................. 2
............................................................. 2
............................................................. 3
............................................................. 4
............................................................. 5
BMR 451 0002/020............................... 6
BMR 451 0002/020............................... 9
........................................................... 12
........................................................... 12
........................................................... 16
........................................................... 17
........................................................... 17
........................................................... 18
........................................................... 21
........................................................... 24
........................................................... 25
........................................................... 28
E
EZIWSON
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
2 (4)
Prepared (also subject responsible if other)
BMR
(Julia You)
SEC/D
451 Digital PoL Regulators
Checked
Date
1/1301-BMR 451
Technical Specification
Uen
2011-12-21
EN/LZT 146
401
R4A
May
2015
© Ericsson AB
Rev
Reference
2
Input
4.5-14
V, Output up to
40
A /
132
W
Ordering Information
Product program
BMR451
Output
0.6 - 3.6 V / 40 A, 132 W
G
Product number and Packaging
Options
Mounting
Mechanical
Digital interface
Configuration file
Packaging
Optional designation
n
1
n
2
Description
0 = Through hole mount version (THP)
1 = Surface mount version (SMD)
0 = lead length 3.56mm
4 = lead length 3mm and pin in paste
option
02 = PMBus and analog voltage adjust
020 = Standard configuration
xxx = Application Specific Configuration
B = Antistatic injection molded tray of 30
products (5 full trays/box = 150 products)
C = Antistatic tape & reel of 130 products
BMR 451 n
1
n
2
n
3
n
4
/n
5
n
6
n
7
n
8
/
n
5
n
1
n
2
n
3
n
4
/
ο
ο
ο
ο
/
/
/
/
ο
Compatibility with RoHS requirements
The products are compatible with the relevant clauses and
requirements of the RoHS directive 2002/95/EC and have a
maximum concentration value of 0.1% by weight in
homogeneous materials for lead, mercury, hexavalent
chromium, PBB and PBDE and of 0.01% by weight in
homogeneous materials for cadmium.
n
7
n
8
n
6
ο
ο
ο
Exemptions in the RoHS directive utilized in Ericsson
Power Modules products include:
-
Lead in high melting temperature type solder (used to
solder the die in semiconductor packages)
-
Lead in glass of electronics components and in
electronic ceramic parts (e.g. fill material in chip
resistors)
-
Lead as an alloying element in copper alloy containing
up to 4% lead by weight (used in connection pins made
of Brass)
Quality Statement
The products are designed and manufactured in an
industrial environment where quality systems and methods
like ISO 9000, 6σ (sigma), and SPC are intensively in use
to boost the continuous improvements strategy. Infant
mortality or early failures in the products are screened out
and they are subjected to an ATE-based final test.
Conservative design rules, design reviews and product
qualifications, plus the high competence of an engaged
work force, contribute to the high quality of our products.
Warranty
Warranty period and conditions are defined in Ericsson
AB’s General Terms and Conditions of Sale. Ericsson AB
does not make any other warranties, expressed or implied
including any warranty of merchantability, effects of product
configurations made by customers or fitness for a particular
purpose.
© Ericsson AB 2015
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
n
3
n
4
n
5
n
6
n
7
n
8
Example: Product number BMR4511002/020 equals a surface mount, open
frame, PMBus and analog voltage adjust, standard configuration variant.
For application specific configurations contact your local Ericsson Power
Modules sales representative.
General Information
Reliability
The failure rate (
λ
) and mean time between failures
(MTBF= 1/
λ
) is calculated at max output power and an
operating ambient temperature (T
A
) of +40°C. Ericsson
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to
calculate the mean steady-state failure rate and standard
deviation (
σ
).
Telcordia SR-332 Issue 2 also provides techniques to
estimate the upper confidence levels of failure rates based
on the mean and standard deviation.
Mean steady-state failure rate,
λ
146 nFailures/h
Std. deviation,
σ
38.3 nFailures/h
MTBF (mean value) for the BMR451 series = 6.9 Mh.
MTBF at 90% confidence level = 5.1 Mh
E
EZIWSON
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
3 (4)
Prepared (also subject responsible if other)
BMR
(Julia You)
SEC/D
451 Digital PoL Regulators
Checked
Date
1/1301-BMR 451
Technical Specification
Uen
2011-12-21
EN/LZT 146
401
R4A
May
2015
© Ericsson AB
Rev
Reference
3
Input
4.5-14
V, Output up to
40
A /
132
W
Safety Specification
General information
Ericsson Power Modules DC/DC converters and DC/DC
regulators are designed in accordance with safety
standards IEC/EN/UL 60950-1
Safety of Information
Technology Equipment.
IEC/EN/UL 60950-1 contains requirements to prevent
injury or damage due to the following hazards:
•
•
•
•
•
•
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
G
Isolated DC/DC converters
It is recommended that a slow blow fuse is to be used at
the input of each DC/DC converter. If an input filter is used
in the circuit the fuse should be placed in front of the input
filter.
In the rare event of a component problem that imposes a
short circuit on the input source, this fuse will provide the
following functions:
•
•
Isolate the fault from the input power source so as
not to affect the operation of other parts of the
system.
Protect the distribution wiring from excessive
current and power loss thus preventing hazardous
overheating.
On-board DC/DC converters and DC/DC regulators are
defined as component power supplies. As components
they cannot fully comply with the provisions of any safety
requirements without “Conditions of Acceptability”.
Clearance between conductors and between conductive
parts of the component power supply and conductors on
the board in the final product must meet the applicable
safety requirements. Certain conditions of acceptability
apply for component power supplies with limited stand-off
(see Mechanical Information for further information). It is
the responsibility of the installer to ensure that the final
product housing these components complies with the
requirements of all applicable safety standards and
regulations for the final product.
Component power supplies for general use should comply
with the requirements in IEC 60950-1, EN 60950-1 and
UL 60950-1
Safety of Information Technology Equipment.
There are other more product related standards, e.g.
IEEE 802.3
CSMA/CD (Ethernet) Access Method,
and
ETS-300132-2
Power supply interface at the input to
telecommunications equipment, operated by direct current
(dc),
but all of these standards are based on
IEC/EN/UL 60950-1 with regards to safety.
Ericsson Power Modules DC/DC converters and DC/DC
regulators are UL 60950-1 recognized and certified in
accordance with EN 60950-1.
The flammability rating for all construction parts of the
products meet requirements for V-0 class material
according to IEC 60695-11-10,
Fire hazard testing, test
flames
– 50 W horizontal and vertical flame test methods.
The products should be installed in the end-use equipment,
in accordance with the requirements of the ultimate
application. Normally the output of the DC/DC converter is
considered as SELV (Safety Extra Low Voltage) and the
input source must be isolated by minimum Double or
Reinforced Insulation from the primary circuit (AC mains) in
accordance with IEC/EN/UL 60950-1.
The galvanic isolation is verified in an electric strength test.
The test voltage (V
iso
) between input and output is
1500 Vdc or 2250 Vdc (refer to product specification).
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
48 and 60 V DC systems
If the input voltage to the DC/DC converter is 75 Vdc or
less, then the output remains SELV (Safety Extra Low
Voltage) under normal and abnormal operating conditions.
Single fault testing in the input power supply circuit should
be performed with the DC/DC converter connected to
demonstrate that the input voltage does not exceed
75 Vdc.
If the input power source circuit is a DC power system, the
source may be treated as a TNV-2 circuit and testing has
demonstrated compliance with SELV limits in accordance
with IEC/EN/UL60950-1.
Non-isolated DC/DC regulators
The input voltage to the DC/DC regulator is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
E
Approved
Ericsson Internal
PRODUCT SPEC
No.
Checked
Date
1 (9)
Reference
Prepared (also subject responsible if other)
ETORHOL, EKAMAGN, EJANARV
2/1301-BMR 451
Technical Specification
0002 Uen
EN/LZT 146
401
R4A
May
2015
© Ericsson AB
Rev
4
BMR
(Julia You)
SEC/D
451 Digital PoL Regulators
ETORHOL
Input
4.5-14
V, Output up to
40
A /
132
W
2010-03-02
E
Absolute Maximum Ratings
Characteristics
T
P1
T
S
V
I
V
O
P
O
Operating temperature (see Thermal Consideration section)
Storage temperature
Input voltage (See Operating Information Section for input and output voltage relations)
Output voltage
Output power
CTRL, SA(0,1), SALERT, SCL, SDA, FLEX
DGND, -S, GND
VOUT, +S
-0.3
-0.3
-0.3
min
-40
-40
-0.3
0.6
typ
max
120
125
16
3.6
132
6.5
0.3
6.5
Unit
°C
°C
V
V
W
V
V
V
Logic I/O voltage
Ground voltage differential
Analog pin voltage
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Fundamental Circuit Diagram
VIN
VOUT
GND
+S
-S
SCL
SDA
SALERT
CTRL
DGND
SA0
SA1
FLEX
DPWM Controller and I/O
E
Approved
Ericsson Internal
PRODUCT SPEC
No.
Checked
Date
2 (9)
Reference
Prepared (also subject responsible if other)
ETORHOL, EKAMAGN, EJANARV
2/1301-BMR 451
Technical Specification
0002 Uen
EN/LZT 146
401
R4A
May
2015
© Ericsson AB
Rev
5
BMR
(Julia You)
SEC/D
451 Digital PoL Regulators
ETORHOL
Input
4.5-14
V, Output up to
40
A /
132
W
2010-03-02
E
Functional Specification
T
P1
= -40 to +85ºC, V
I
= 4.5 to 14 V
Typical values given at: T
P1
= +25°C, V
I
= 12 V, max I
O
, unless otherwise specified under Conditions
Configuration File: 190 10-CDA 102 900/020
Characteristics
SMBus monitoring
VIN_READ, 0x88h
VOUT_READ, 0x8Bh
IOUT_READ, 0x8Ch
f
s
Switching frequency
C
ISMBus
Internal capacitance
C
I
Internal input capacitance
Fault Protection Characteristics
UVLO Threshold
Input Under
Voltage Lockout,
UVLO
Set point accuracy
Hysteresis
Delay
UVP threshold
Factory default
(Output voltage)
Over/Under
OVP threshold
Factory default
Voltage Protection,
OVP/UVP fault response
Factory default
OVP/UVP
time
Over Current
Protection,
OCP
Over Temperature
Protection,
OTP at T
P1
Set point accuracy
OCP threshold
OCP protection delay
OTP threshold
OTP hysteresis
Io
Factory default
Factory default
Factory default
Factory default
-20
50
45
120
°C
15
85
115
25
+20
Factory default
-100
0.4
2.5
4.0
100
V
mV
V
µs
% V
OUT
% V
OUT
µs
%
A
µs
Accuracy vs. V
I
Accuracy vs. V
O
Accuracy vs. I
O
Factory default
SMBus signals, SDA, SCL
-3
-1
-20
320
10
140
3
1
20
%
%
%
kHz
pF
µF
Conditions
min
typ
max
Unit
General Electrical Characteristics
Logic Input/Output Characteristics
Logic input low threshold (V
IL
)
Logic input high threshold (V
IH
)
Logic output low (V
OL
)
Logic output high (V
OH
)
Setup time, SMBus (t
set
)
Hold time, SMBus (t
hold
)
CTRL, SCL, SDA, FLEX
SALERT, SCL, SDA, FLEX
I
OL
≤
4 mA
SALERT, SCL, SDA, FLEX
I
OL
≥
-2 mA
See Note 1
See Note 1
0.8
2.0
0.4
2.25
300
250
V
V
V
V
ns
ns
Note 1: See operation information section for I2C/SMBus Setup and Hold Times – Definitions