NEW PRODUCT
NEW PRODUCT
NEW PRODUCT
UGF10FCT AND UGF10GCT
ULTRAFAST SOFT RECOVERY RECTIFIER
Reverse Voltage
- 300 to 400 Volts
ITO-220AB
0.405 (10.27)
0.383 (9.72)
0.188 (4.77)
0.172 (4.36)
0.110 (2.80)
0.100 (2.54)
0.140 (3.56)
DIA.
0.130 (3.30)
0.131 (3.39)
DIA.
0.122 (3.08)
Forward Current
- 10.0 Amperes
FEATURES
♦
Plastic package has Underwriters Laboratories
Flammability Classification 94V-0
♦
Ideally suited for free wheeling diode power factor
correction applications
♦
Soft recovery characteristics
♦
Excellent high temperature switching
♦
Optimized to reduce switching losses
♦
High temperature soldering guaranteed:
250°C, 0.25" (6.35mm) from case for 10 seconds
♦
Glass passivated chip junction
0.600 (15.5)
0.580 (14.5)
PIN
1
2
3
0.670 (17.2)
0.646 (16.4)
0.350 (8.89)
0.330 (8.38)
0.191 (4.85)
0.171 (4.35)
0.560 (14.22)
0.530 (13.46)
0.060 (1.52)
0.110 (2.80)
0.100 (2.54)
MECHANICAL DATA
Case:
ITO-220AB molded plastic body
Terminals:
Plated leads, solderable per MIL-STD-750,
Method 2026
Polarity:
As marked
Mounting Position:
Any
Weight:
0.08 ounce, 2.24 grams
Mounting Torque:
5 in. - lbs. max.
0.037 (0.94)
0.027 (0.69)
0.105 (2.67)
0.095 (2.41)
0.022 (0.55)
0.014 (0.36)
PIN 1
PIN 3
PIN 2
0.205 (5.20)
0.195 (4.95)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
UGF10FCT
UGF10GCT
UNITS
Maximum repetitive peak reverse voltage
Working peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current at T
C
=100°C
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method) per leg
Maximum instantaneous forward voltage per leg
I
F
= 5A
Maximum reverse leakage current
at working peak reverse voltage
Maximum Reverse recovery time per leg at
I
F
=1.0A, di/dt=100A/µs, V
R
=30V, I
rr
=0.1 I
RM
Maximum reverse recovery current per leg at
I
F
=5A, di/dt=50A/µs,V
R
=30V
Maximum stored charge per leg
I
F
=2A, di/dt=20A/µs, V
R
=30V, I
rr
=0.1 I
RM
Typical thermal resistance from junction to case per leg
Operating junction and storage temperature range
T
J
=25°C
T
J
=150°C
T
J
=25°C
T
J
=100°C
V
RRM
V
RWM
V
RMS
V
DC
I
(AV)
I
FSM
300
225
210
300
10
60A
1.30
1.05
10
200
35
50
3.0
50
400
300
280
400
Volts
Volts
Volts
Volts
Amps
Amps
V
F
I
R
t
rr
t
rr
Volts
µA
ns
ns
Amps
nC
°C/W
°C
Maximum reverse recovery time per leg at I
F
=0.5A, I
R
=1.0A, I
rr
=0.25A
T
C
=100°C
I
RM
Q
rr
R
ΘJC
T
J
, T
STG
6.0
-40 to +150
4/98
RATINGS AND CHARACTERISTIC CURVES UGF10FCT AND UGF10GCT
FIG. 1 -FORWARD CURRENT DERATING CURVE
AVERAGE FORWARD CURRENT, AMPERES
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT PER LEG
15
RESISTIVE OR INDUCTIVE LOAD
100
PEAK FORWARD SURGE CURRENT,
AMPERES
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
T
C
=105°C
10
10
5
0
1
0
25
50
75
100
125
150
CASE TEMPERATURE, °C
1
10
NUMBER OF CYCLES AT 60 H
Z
100
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
100
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
PER LEG
INSTANTANEOUS REVERSE LEAKAGE CURRENT,
MICROAMPERES
T
J
=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
1,000
INSTANTANEOUS FORWARD CURRENT,
AMPERES
T
J
=125°C
10
T
J
=125°C
100
T
J
=100°C
1
T
J
=100°C
10
0.1
T
J
=25°C
1
T
J
=25°C
0.1
0.01
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
20
40
60
80
100
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 5 - REVERSE SWITCHING CHARACTERISTICS
PER LEG
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
FIG. 6 - TYPICAL JUNCTION CAPACITANCE PER LEG
STORED CHARGE/REVERSE RECOVERY TIME,
nC/ns
300
250
200
100
@5A, 50A/µs
T
J
=125°C
f=1.0 MHz
Vsig=50MVp-p
@2A, 20A/µs
CAPACITANCE, pF
150
@5A, 50A/µs
10
100
50
@2A, 20A/µs
@1A, 100A/µs
t
rr
Q
rr
0
25
50
75
100
125
1
0.1
1
10
100
1,000
JUNCTION TEMPERATURE, °C