EEWORLDEEWORLDEEWORLD

Part Number

Search

KCA-E1E

Description
Power/Signal Relay, 3PDT, Momentary, 5355mW (Coil), 25A (Contact), 28VDC (Contact), AC Input, AC/DC Output, Socket Mount,
CategoryMechanical and electronic products    relay   
File Size788KB,12 Pages
ManufacturerEsterline Power Systems
Download Datasheet Parametric View All

KCA-E1E Overview

Power/Signal Relay, 3PDT, Momentary, 5355mW (Coil), 25A (Contact), 28VDC (Contact), AC Input, AC/DC Output, Socket Mount,

KCA-E1E Parametric

Parameter NameAttribute value
MakerEsterline Power Systems
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 25.6 V, COIL RELEASE VOLTAGE(AC): 10 V, PANEL MOUNTABLE
body width25.78 mm
body height25.4 mm
Body length or diameter25.78 mm
Coil current (AC) maximum value0.225 A
Coil power5355 mW
Maximum coil voltage (AC)28 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load25A@115VAC
Maximum contact current (AC)25 A
Maximum contact current (DC)25 A
Contact (DC) maximum rated R load25A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life50000 Cycle(s)
JESD-609 codee0
Installation featuresSOCKET MOUNT
operating hours21 ms
Maximum operating temperature125 °C
Minimum operating temperature-70 °C
physical size25.78mm x 25.78mm x 25.4mm
GuidelineMIL-PRF-6106
Relay actionMOMENTARY
Relay function3PDT
Relay typePOWER/SIGNAL RELAY
release time50.1 ms
sealCORROSION PROOF; HERMETICALLY SEALED
surface mountNO
Terminal surfaceTIN LEAD
Termination typeSNAP-ON
SERIES KCA
ENGINEERING DATA SHEET
RELAY - NONLATCH - AC COIL
3 PDT, 25 AMP
All welded construction
Contact arrangement
Designed to the
performance standards of
3 PDT
MIL-PRF-6106
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Low level, 28 Vdc; 115
Vac, 400 Hz, 1Ø and
115/200 Vac, 400 Hz, 3Ø
0.188lb max
1.01in x 1.01in x 1.00in
Weight
Dimensions
Hermetically sealed, corrosion resistant metal can.
Detail specifications and ordering data appear on the following
pages.
APPLICATION NOTES:
102
007
APPLICABLE SOCKET:
SO-1062-8917
SO-1057-8912 (D-MOUNT)
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating
per pole and load
type [1]
Resistive [3]
Inductive [2]
Motor
Lamp
Overload
Rupture
Load current in Amps
@28 Vdc
25
12
10
5
50
60
@115 Vac
400 Hz
25
15
10
5
80
100
@115/200 Vac
400 Hz, 3Ø
25
15
10
5
80
100
@115/200 Vac
60 Hz, 3Ø [7]
2.5
2.5
2
1
N/A
N/A
@230/400 Vac
400 Hz, 3Ø [8]
5
5
2
2
N/A
N/A
Featuring
LEACH
©
power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 07/10
- 154 -
Page 1 of 4
Could you please tell me what is the circuit behind the DA converter generally connected to?
Could you please tell me what is the general connection of the circuit behind the DA converter? I am using TLV5619, 12-channel digital quantity to analog quantity, do I need to add an emitter follower...
gougou329 Analog electronics
LED Driver
Dear brothers and sisters, please teach me how to learn LED driving! Thank you!...
Maywolf Embedded System
Millimeter wave basics
I am new to millimeter wave and have run a demo. Now I want to use A[/size][/font][/color]WR1443[color=#555555][font="][size=14px] to build a system that analyzes the distance and speed of obstacles a...
施奈德 Analogue and Mixed Signal
Solar photovoltaic grid-connected power generation and its inverter control
Need help with solar photovoltaic grid-connected power generation and its inverter control PDF download. . . . . . . . . . . . . . . . . . . . ....
木头人切 Switching Power Supply Study Group
MPLAB SNAP is finally here
MPLAB SNAP finally arrived, but it was delayed for a week because of the Mid-Autumn Festival. The board is small and delicate. Seeing MPLAB SNAP suddenly reminded me of the AVR Dragon....
dcexpert MCU
TJA1042
[color=#505050][font="][size=12px]I would like to ask you experts what is the use of the SPILT pin of the TJA1042 chip? How is it connected? Can you tell me in detail? [/size][/font][/color]...
14101603 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2037  2231  2677  2326  918  42  45  54  47  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号