Model MVL7 AC-AC Long Stroke LVDT
Order Code BY125
n
n
n
0.25% Non-Linearity
Stainless Steel
0.5 to 8.0 in. Ranges
Wiring Codes
Wire
Red
Yellow
Blue
Green
Black
Supply
(+) Supply (Calibrated @ 3V RMS 5 kHz)
Supply Return
Output
Output Return
Secondary Center Tap
(normally not connected)
Dimensions
M5 x .08
ø 0.19 in.
ø 0.81 in.
0.35 in.
L
X Nominal
Electric Zero Point
Range
Codes
HP
HQ
HR
HS
HT
HU
HV
Available
Stroke
Ranges
+/-
+/-
+/-
+/-
+/-
+/-
+/-
0.5
1.0
2.0
3.0
4.0
6.0
8.0
in.
in.
in.
in.
in.
in.
in.
L (in.)
5.0
6.0
10.6
15.0
16.75
24.25
31.75
X (in.)
1.7
2.7
3.2
4.7
5.2
7.2
10.2
Approx. Approx.
Body Armature Typical F.S.
Weight Weight Output at 3V
RMS
(oz.)
(oz.)
6
8
13
16
20
29
42
1.25
1.75
2.0
2.2
2.5
4.0
5.1
2.4V
3.0V
4.8V
4.5V
9.5V
7.2V
4.8V
RMS
RMS
RMS
RMS
RMS
RMS
RMS
Performance
Stroke Range................+/- 0.5 to 8.0 in.
Non-Linearity (max.)................+/- 0.25% Full Scale
Non-Repeatability (max.)................Not Applicable
Output Sensitivity................See table above
Resolution................Infinite
Temperature, Operating................-58° to 257°F
Temperature, Effect
Zero (max.)................0.006% Full Scale/°F
Span (max.)................0.006% Full Scale/°F
Element Type................AC-AC LVDT
Input Supply (calibrated)................3 V RMS @ 5 kHz
Input Supply (acceptable)................1-7 V RMS @ 2-10 kHz
Electrical Termination................Multiconductor shielded cable
Material................Stainless Steel
Probe Material................Stainless Steel
Armature Type................Free Unguided
Probe Thread................M5 x 0.8
Weight................See table above
Spring Force (max.)................Not Applicable
Environmental
Electrical
Mechanical
372
1-888-282-9891
www.honeywell.com/sensotec
Model MVL7
Typical System Diagram
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
Model MVL7
Mounting Options
Rod End Bearing
Mounting Blocks
AA937 Mounting Block
In-Line Amplifiers
DLD-VH
DLD-CH
(Required for AC LVDT’s
and if AC input display units
are not being used)
AC Input Display Units
DM
SC500
SC1000
SC2000
SC3004
Options
Fast Track Delivery
Stroke Ranges
+/- 0.5 to 8.0 in.
TM405. Axial Bendix connector
Multiconductor Shielded Cable
on body Radial (side)
TM406. Bendix connector on
(6 ft.)
body
TM49. Axial cable exit
TM511. 13/16 - 32 UNF
L10. +/- 0.1% max. linearity
(less than or equal to +/- 4 in.)
TM315. 400° F up to +/- 4.0 in.
Built to Order
Range Codes
Range
+/-
+/-
+/-
+/-
+/-
+/-
+/-
0.5
1.0
2.0
3.0
4.0
6.0
8.0
in.
in.
in.
in.
in.
in.
in.
Range Code
HP
HQ
HR
HS
HT
HU
HV
Electrical
Termination
Electrical Cable
Orientation
Mounting Threads
Improved
Linearity
Higher
Temperature
Supplied as standard
Special Customer Requirements
(Consult Factory)
Moisture resistant
Radiation resistance 100M rads
Longer cable length, limited on certain models
Threaded body
T.E.D.S. IEEE 1451.4 module
Signature Calibration
-Not RoHS Compliant
How to Order
The order code consists of the product model, the desired range code and the available options.
Sample Code:
BY125
Model Code
HQ
Range Code
L10
Options Code
1-888-282-9891
www.honeywell.com/sensotec