EEWORLDEEWORLDEEWORLD

Part Number

Search

2036-40-AFLF

Description
Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long
CategoryWireless rf/communication    Telecom circuit   
File Size525KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric Compare View All

2036-40-AFLF Overview

Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long

2036-40-AFLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT PACKAGE
Reach Compliance Codecompli
JESD-30 codeX-XXSS-X3
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTin (Sn)
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced Mini-TRIGARD™
5 mm diameter, 7.5 mm long
UL Recognized
RoHS compliant* versions available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2036 Series - Miniature 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31
Model No.
2036-07
2036-09
2036-15
2036-20
2036-23
2036-25
Characteristic
DC Sparkover ±20 %
@ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
75 V
250 V
525 V
90 V
250 V
550 V
150 V
350 V
500 V
200 V
425 V
575 V
230 V
450 V
600 V
250V
475 V
625 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Model No.
2036-30
2036-35
2036-40
2036-42
2036-47
2036-60
300 V
500 V
650 V
350 V
600 V
750 V
400 V
650 V
825 V
420 V
675 V
850 V
470 V
750 V
950 V
600 V
850 V
1100 V
Impulse Transverse Delay ..................100 V/µs ................................................................................. < 75 ns
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 2 pF
DC Holdover Voltage
1
.......................135 V, (52 V for Model 2036-07 & 2036-09, ........................... < 150 ms
80 V for Model 2036-15)
Impulse Discharge Current .................20000 A, 8/20 µs
2
................................................................... 1 operation minimum
10000 A, 8/20 µs .................................................................... > 10 operations
2000 A, 10/350 µs .................................................................. 1 operation
200 A, 10/1000 µs ................................................................. > 300 operations
200 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ............20 Arms, 1 s
2
.......................................................................... 1 operation minimum
10 Arms, 1 s ........................................................................... > 10 operations
Operating Temperature....................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Optional Switch-Grade Fail-Short device available.
Notes:
• UL recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to
ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
1
2
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.

2036-40-AFLF Related Products

2036-40-AFLF 2036-07-BFLF 2036-20-BFLF 2036-40-BFLF 2036-42-BFLF 2036-47-AFLF
Description Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long
Is it Rohs certified? conform to conform to conform to conform to conform to conform to
package instruction ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE
Reach Compliance Code compli compli compli compli compli compli
JESD-30 code X-XXSS-X3 X-XXSS-X3 X-XXSS-X3 X-XXSS-X3 X-XXSS-X3 X-XXSS-X3
JESD-609 code e3 e3 e3 e3 e3 e3
Humidity sensitivity level 1 1 1 1 1 1
Number of functions 1 1 1 1 1 1
Number of terminals 3 3 3 3 3 3
Maximum operating temperature 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C
Minimum operating temperature -55 °C -55 °C -55 °C -55 °C -55 °C -55 °C
Package body material UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Package shape UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Package form SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE
Peak Reflow Temperature (Celsius) NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Certification status Not Qualified Not Qualified Not Qualified Not Qualified Not Qualified Not Qualified
surface mount NO NO NO NO NO NO
Telecom integrated circuit types SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT
Temperature level OTHER OTHER OTHER OTHER OTHER OTHER
Terminal surface Tin (Sn) Tin (Sn) Tin (Sn) Tin (Sn) Tin (Sn) Tin (Sn)
Terminal form UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Terminal location UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Maximum time at peak reflow temperature NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Base Number Matches 1 1 1 1 1 1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2001  1889  2167  1296  831  41  39  44  27  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号