2036-07-BFLF

Description
Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long
CategoryWireless rf/communication    Telecom circuit   
File Size525KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Environmental Compliance
Download Datasheet Parametric Compare View All

2036-07-BFLF Overview

Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long

2036-07-BFLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT PACKAGE
Reach Compliance Codecompli
JESD-30 codeX-XXSS-X3
JESD-609 codee3
Humidity sensitivity level1
Number of functions1
Number of terminals3
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
Package shapeUNSPECIFIED
Package formSPECIAL SHAPE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Telecom integrated circuit typesSURGE PROTECTION CIRCUIT
Temperature levelOTHER
Terminal surfaceTin (Sn)
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Base Number Matches1
*R
oH
V E S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
Balanced Mini-TRIGARD™
5 mm diameter, 7.5 mm long
UL Recognized
RoHS compliant* versions available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2036 Series - Miniature 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31
Model No.
2036-07
2036-09
2036-15
2036-20
2036-23
2036-25
Characteristic
DC Sparkover ±20 %
@ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
75 V
250 V
525 V
90 V
250 V
550 V
150 V
350 V
500 V
200 V
425 V
575 V
230 V
450 V
600 V
250V
475 V
625 V
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Model No.
2036-30
2036-35
2036-40
2036-42
2036-47
2036-60
300 V
500 V
650 V
350 V
600 V
750 V
400 V
650 V
825 V
420 V
675 V
850 V
470 V
750 V
950 V
600 V
850 V
1100 V
Impulse Transverse Delay ..................100 V/µs ................................................................................. < 75 ns
Insulation Resistance .........................100 V (50 V for Model 2036–07 & 2036-09)........................... > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 2 pF
DC Holdover Voltage
1
.......................135 V, (52 V for Model 2036-07 & 2036-09, ........................... < 150 ms
80 V for Model 2036-15)
Impulse Discharge Current .................20000 A, 8/20 µs
2
................................................................... 1 operation minimum
10000 A, 8/20 µs .................................................................... > 10 operations
2000 A, 10/350 µs .................................................................. 1 operation
200 A, 10/1000 µs ................................................................. > 300 operations
200 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ............20 Arms, 1 s
2
.......................................................................... 1 operation minimum
10 Arms, 1 s ........................................................................... > 10 operations
Operating Temperature....................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Optional Switch-Grade Fail-Short device available.
Notes:
• UL recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to
ground.
• Sparkover limits after life ±25 %, IR >10
8
Ω (-25 %,+30 % for Model 2036-07, 2036-09 and 2036-60).
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available, contact factory.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
1
2
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.

2036-07-BFLF Related Products

2036-07-BFLF 2036-20-BFLF 2036-40-AFLF 2036-40-BFLF 2036-42-BFLF 2036-47-AFLF
Description Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long
Is it Rohs certified? conform to conform to conform to conform to conform to conform to
package instruction ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE ROHS COMPLIANT PACKAGE
Reach Compliance Code compli compli compli compli compli compli
JESD-30 code X-XXSS-X3 X-XXSS-X3 X-XXSS-X3 X-XXSS-X3 X-XXSS-X3 X-XXSS-X3
JESD-609 code e3 e3 e3 e3 e3 e3
Humidity sensitivity level 1 1 1 1 1 1
Number of functions 1 1 1 1 1 1
Number of terminals 3 3 3 3 3 3
Maximum operating temperature 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C
Minimum operating temperature -55 °C -55 °C -55 °C -55 °C -55 °C -55 °C
Package body material UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Package shape UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Package form SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE SPECIAL SHAPE
Peak Reflow Temperature (Celsius) NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Certification status Not Qualified Not Qualified Not Qualified Not Qualified Not Qualified Not Qualified
surface mount NO NO NO NO NO NO
Telecom integrated circuit types SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT SURGE PROTECTION CIRCUIT
Temperature level OTHER OTHER OTHER OTHER OTHER OTHER
Terminal surface Tin (Sn) Tin (Sn) Tin (Sn) Tin (Sn) Tin (Sn) Tin (Sn)
Terminal form UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Terminal location UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED UNSPECIFIED
Maximum time at peak reflow temperature NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Base Number Matches 1 1 1 1 1 1
About the problem of thermocouple measuring a certain metal material sample
I recently encountered a practical problem, the situation is as follows: there is a metal alloy material as a test sample, the two ends are clamped with pure copper, the copper pillars on both sides c...
zl36 Test/Measurement
TI flashlight disassembly
After I got the flashlight, it flashed for only a second and then stopped working. I had no choice but to disassemble it! Later, I reassembled it and it worked again, haha. The following pictures are ...
dontium Analog electronics
Switching Power Supply Interest Group 13th Task
Question for the 12th Thinking Session   In the design example of the forward converter transformer given in Section 3.2.5 of Chapter 3 of "Mastering Switching Power Supply Design (2nd Edition)", whic...
maychang Switching Power Supply Study Group
【Show samples】+Learn energy harvesting and wireless sensing
[align=left]I have been learning wireless radio for nearly a year, and I am ready to make some wireless radio stuff of my own. I have a cc430-Chronous that I bought before, but it is not easy to learn...
mars4zhu TI Technology Forum
A not very professional question...
Today I just made a program-controlled car using the NRF24L01 wireless module, but it is still in the early stages and can only control movement. I want to add some auxiliary functions, such as transm...
xing_xing RF/Wirelessly
Is the ST website down? Or is it crashing?
This gray special effect of the website hinders all operations. Neither IE nor Chrome works. In fact, whether to accept cookies, just click accept, and that's it. All operations are blocked....
wsmysyn Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2362  530  2342  1261  528  48  11  26  38  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号