EEWORLDEEWORLDEEWORLD

Part Number

Search

56.44.9.024.2321

Description
Electromechanical Relay, 4PDT, 26.4VDC (Coil), 1300mW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.44.9.024.2321 Overview

Electromechanical Relay, 4PDT, 26.4VDC (Coil), 1300mW (Coil), Random, AC/DC Output

56.44.9.024.2321 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (DC)20.4 V
Coil power1300 mW
Coil resistance490 Ω
Maximum coil voltage (DC)26.4 V
Nominal coil voltage24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Input switching control typeRandom
Number of terminals14
operating hours10 ms
PCB hole count14
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
FAQ for Acceleration Sensors
Serial number question address 1, [color=#000][font=Helvetica, Arial, sans-serif]Determination of the origin of the accelerometer's own coordinate system[/font][/color][font=Helvetica, Arial, sans-ser...
laoguo Sensor
EEWORLD University ---- FRAM Series MSP430FR59xx LaunchaPad Introductory Training
FRAM Series MSP430FR59xx LaunchaPad Getting Started Training : https://training.eeworld.com.cn/course/231? ? FRAM stands for Ferroelectric Random Access Memory. ? This is the latest non-volatile memor...
chenyy Energy Infrastructure?
Where can I download VC++6 and MSDN?
I started looking for it last night, but I still haven't found what I want. I want the English version....
dontium Integrated technical exchanges
Cadence cannot preview and place PCB package
cadence: 16.6-2015 Schematic: OrCAD Capture CIS PCB: Allegro PCB Design XL Netlist import information:Place PCB package: (unplaced component list)(built-in library component list)...
Tobey PCB Design
How to implement transcendental functions in Verilog language
How does Verilog implement operations such as rounding and logarithm in C language?...
eeleader FPGA/CPLD
Editor's Recommendation: Newbies to RF/Wireless should read this first!
There are many good posts in the RF forum. I want to sort out the best posts and put them here, but I can't. One reason is that I don't know much about RF, and the main reason is that there are too ma...
高进 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2027  467  719  2816  480  41  10  15  57  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号