The JDSU near infrared fused coupler splits or combines light at any selected
wavelength from 700 to 1150 nm. Designed for applications in fiber laser, sensor
and avionics applications, the coupler utilizes low loss fused fiber technology. No
light leaves the fiber and therefore no alignment is required; and there are no
unwanted reflections. Furthermore the output fiber pigtails may be directly
integrated into beam delivery systems.
NORTH AMERICA
:
800 498-JDSU (5378)
WORLDWIDE
:
+800 5378-JDSU
WEBSITE
:
www.jdsu.com
FUSED COUPLER, NEAR INFRARED
2
Configuration
1x2
P1 (Red) COMMON (Input)
P2 (Blue) SIGNAL (Input)
P3 (Red) TAP (Output)
2x2
P1 (Red) COMMON (Input)
P2 (Blue) SIGNAL (Input)
P4 (Blue)
P3 (Red) TAP (Output)
Insertion Loss
Coupling Ratio
Grade
Available Housing Option
Signal Path Insertion Loss
1, 2
(Maximum)
0.9 dB
1.1 dB
1.5 dB
1.7 dB
2.2 dB
2.4 dB
3.0 dB
3.2 dB
3.8 dB
4.0 dB
Tap Path Insertion Loss
1, 2
(Maximum)
12.2 dB
12.4 dB
8.4 dB
8.6 dB
6.4 dB
6.5 dB
4.9 dB
5.1 dB
3.8 dB
4.0 dB
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
A
B
A
B
A
B
A
B
A
B
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
1. Insertion loss at operating wavelength range (not including PDL, TDL or connector losses).
2. In 2x2 couplers with a coupling ratio of 20% or lower, insertion loss is not specified for launch through second input port (P4).
FUSED COUPLER, NEAR INFRARED
3
Housing Option
Housing Code
3
4
5
6
Description
Regular
Ø 0.9 mm slim
Ø 0.9 mm semi-ruggedized
Ø 3.0 mm fully ruggedized
1x2, 2x2 Dimensions (mm)
3.0 (Ø) x 50 (L)
3.0 (Ø) x 60 (L)
5.0 (Ø) x 75 (L)
80 (L) x 10 (W) x 8 (H)
Pigtail
Primary-coated fiber
Ø 0.9 mm loose-tube
Ø 0.9 mm loose-tube
Ø 3.0 mm fan-out sleeving
Specifications
Parameter
Operating wavelength range
1
Excess loss
Return loss/Directivity
Pigtail tensile load
Optical power handling
Operating temperature range
2
Storage temperature range
Fiber type
Grade A
Grade B
Typical
Minimum
Maximum
Maximum
Any wavelength within the 700 to 1150 nm range
0.30 dB
0.50 dB
50 dB
5N
4W
-40 to 75 °C
-40 to 85 °C
Speciality fiber
1. Any specific wavelength point from within the range 633 to 850 nm may be selected. For wavelengths outside of this range, contact JDSU with specific requirements.
2. For connectorised component, operating temperature range is -5 to 75 °C.
FUSED COUPLER, NEAR INFRARED
4
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
customer.service@jdsu.com.
Sample: FFS-060K31A10 (Fused Fiber Speciality Coupler, 1060 nm, 50/50 coupling ratio, regular housing, 1x2, A grade, 1 m
pigtails, no connectors)
FFS-
Code
7
8
9
0
1
Wavelength
(First Digit)
7xx nm
8xx nm
9xx nm
10xx nm
11xx nm
Code
A
C
E
H
K
Coupling Ratio
1
10%
20%
30%
40%
50%
Code
1
2
Configuration
1x2
2x2
Code
0
1
3
5
9
A
B
Connectors
2, 4
None
FC/PC
FC/APC
SC/APC
FC/UPC
SC/UPC
LC
5
Code
A
B
Grade
Grade A
Grade B
Code
Wavelength
(Second and
Third Digit)
Examples:
33
x33 nm
32
x32 nm
57
x57 nm
Code
3
4
5
6
Housing
2
Regular
Ø 0.9 mm slim
Ø 0.9 mm
semi-ruggedised
Ø 3.0mm fully
ruggedised
Code
0
1
Pigtail Length
3
(Minimum)
0.5 meter
1 meter
1. Other coupling ratio are available. Please contact JDSU for ordering codes of coupling ratios not listed.
2. Connectors may be fitted to housing types 4, 5 and 6. For connectorisation of housing type 3, please contact JDSU sales office.
3. Minimum pigtail length. Other pigtail lengths are available on request. When the pigtail has been modified to include a
connector, pigtail length measurment includes the connector end face.
4. Excess Loss in specification table does not include connector losses.
5. LC connector is not available for housing code 6, fully ruggedised housing.
LC is a registered trademark of Lucent Technologies.
E840-DTU Unboxing
1. First, understand the purpose of e840 through the user manual and re-formulate the evaluation plan.SIM cardAfter opening the package, check that there is no damage. Prepare a SIM ...
To put it simply, high-frequency circuits are radio circuits, but they do not involve microwave circuits (microwaves are used to process circuits above one gigahertz, and they must start from the elec...
I have read a post on this forum https://bbs.eeworld.com.cn/redirect.php?tid=110546goto=lastpost , which mentioned that "After STM32 receives an IN event and completes the transmission, the software d...
Texas Instruments (TI) has more than 25 years of experience in the video field, with products covering every link in the video chain, from the creation of original content to the final viewing experie...
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
The rectified DC voltage is then converted back to AC using power electronics such as insulated gate bipolar transistors.
The output voltage is switched on and off at a high frequency, control...[Details]
The emergence and development of street lamps are inseparable from the prosperity and progress of cities, which makes street lamps useful. Conversely, street lamps also make the night of the city n...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]