RF AMPLIFIER
MODEL
TM5125PM
Features
!
High Gain: 20.5 dB Typical
!
High Power: +24 dBm Typical
!
Low Noise: 2.0 dB Typical
!
Operating Temp. - 55 ºC
to +85
ºC
!
Environmental Screening Available
Available as:
TM5125PM, 4 Pin TO-8 (T4)
TN5125PM, 4 Pin Surface Mount (SM3)
BX5125PM, Connectorized Housing (H1)
Typical Intermodulation Performance at 25 º C
Second Order Harmonic Intercept Point....... +58 dBm (Typ.)
Second Order Two Tone Intercept Point........ +52 dBm (Typ.)
Third Order Two Tone Intercept Point ........... +40 dBm (Typ.)
Maximum Ratings
MIN/MAX
Ta = -55 ºC to +85 ºC
10 - 100 MHz
19.5 Min./21 Max.
+22.5
- 23
2.0:1
2.0:1
3.0
+15
90
Min.
Max.
Max.
Max.
Max.
Max.
Specifications
CHARACTERISTIC
Frequency
Gain (dB)
Power @ 1 dB
Comp. (dBm)
Reverse
Isolation (dB)
VSWR
In
Out
Noise figure (dB)
Power
Vdc
mA
TYPICAL
Ta= 25 ºC
5 - 125 MHz
20.5
+24.0
- 24
1.7:1
1.35:1
2.0
+15
80
Ambient Operating Temperature .............. -55ºC to + 100 ºC
Storage Temperature ............................... -62ºC to + 125 ºC
Case Temperature ................................................. + 125 ºC
DC Voltage ......................................................... + 18 Volts
Continuous RF Input Power ................................. + 13 dBm
Short Term RF Input Power ............. 50 mW (1 Minute Max.)
Maximum Peak Power .................... 0.5 Watt (3
µsec
Max.)
Guaranteed Phase Noise Performance
(dBc/Hz)
Frequency
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Typical
- 162
- 175
- 176
- 176
- 176
Guarantee (min.)
-158
-172
-174
-174
-174
*
Note: Care should always be taken to effectively ground the case of each unit.
Typical Performance Data
22
21
20
19
18
+26
+25
+24
+23
+22
2.0
1.5
1.0
Start 10 MHz
Start 10 MHz
Stop 100 MHz
Gain (dB)
0
-10
- 20
- 30
- 40
3
2
Reverse Isolation (dB)
-130
-140
-150
Start 10 MHz
Stop 100 MHz
-160
-170
-180
-190
100
Phase Noise (dBc/Hz)
1 dB Comp. (dBm)
Noise Figure (dB)
1K
10K
100K
1M
Input VSWR
Stop 100 MHz
1
2.0
1.5
1.0
Start 10 MHz
Output VSWR
Stop 100 MHz
______Guarantee __ __ __Typical
Phase Noise
Carrier Frequency: 80 mHz
*
Power Output:
Test Conditions:
+24 dBm
!
!
!
!
Start 10 MHz
Stop 100 MHz
Start 10 MHz
Stop 100 MHz
Temperature: 25 ºC
Agilent ES5500 System
Legend
+ 25 ºC
+ 85 ºC - - - - - - -55 ºC
Linear S-Parameters
FREQ.
– – – – S11– – – –
–
– – – – S12– –
– – – – S22– –
MHz
Mag
Deg
Mag
Deg
Mag
Deg
Mag
Deg
=========================================================================================================
5
.05 -151.80
.26 -19.89
9.94 -151.50
.39
-32.94
10
.05 -172.06
.15 -23.55
10.56 -168.32
.29
-26.29
20
.05
8.61
.12
169.91
176.24
10.79
.26
-20.09
50
.05
.25
18.79
.17
154.52
162.45
10.79
-25.12
75
.06
15.63
.20
139.83
150.84
10.69
.26
-34.68
.06
8.47
.22
126.88
140.02
10.52
100
.27
-46.93
2707 Black Lake Place, Philadelphia, PA 19154
TEL 215-464-4000
· · · ·
FAX 215-464-4001
03/31/03