Description
Electric Fuse, Time Delay Blow, 0.6A, 600VAC, 300VDC, 200000A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size216KB,3 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

LP-CC-6/10 Overview

Electric Fuse, Time Delay Blow, 0.6A, 600VAC, 300VDC, 200000A (IR), Inline/holder

LP-CC-6/10 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerCooper Industries
Reach Compliance Codecompliant
Other featuresRATED BREAKING CAPACITY AT 300 VDC: 20000 A
Fusing characteristicsTIME DELAY
body height38.1 mm
Body length or diameter10.3 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberLP-CC
Installation featuresINLINE/HOLDER
physical size10.3mm x 38.1mm
Rated breaking capacity200000 A
Rated current0.6 A
Rated voltage (AC)600 V
Rated voltage (DC)300 V
GuidelineCE; CSA; UL
surface mountNO
Terminal shapeEND CAP
Low-Peak™ Class CC
LP-CC — 600Vac/300Vdc,
1
2
-30A Time-Delay Fuses
Dimensions - in (mm)
1.5" (± 0.031)
(38.1mm)
0.41" (± 0.005)
(10.3mm)
Description:
Ultimate protection Class CC current-limiting,
time-delay fuses. Time-delay – 12 seconds (minimum) at
200% of rated current.
Catalog Symbol:
LP-CC-(amp)
Ratings:
Volts — 600Vac,
— 300Vdc (
1
2
-2
8
10
A, 20-30A)
— 150Vdc (3-15A)
Amps —
1
2
-30A
IR — 200kA Vac RMS Sym.
— 20kA Vdc
Agency Information:
CE, Std. 248-4, Class CC, UL Listed, Guide JDDZ, File E4273
CSA Certified; Class 1422-02, File 53787
Catalog Numbers (amps)
LP-CC-
1
2
LP-CC-
6
10
LP-CC-
8
10
LP-CC-1
LP-CC-1
1
8
LP-CC-1
1
4
LP-CC-1
4
10
Amp Rating
0-30
LP-CC-1
1
2
LP-CC-1
6
10
LP-CC-1
8
10
LP-CC-2
LP-CC-2
1
4
LP-CC-2
1
2
LP-CC-2
8
10
LP-CC-3
LP-CC-3
2
10
LP-CC-3
1
2
LP-CC-4
LP-CC-4
1
2
LP-CC-5
LP-CC-5
6
10
Carton Qty.
10
LP-CC-6
LP-CC-6
1
4
LP-CC-7
LP-CC-7
1
2
LP-CC-8
LP-CC-9
LP-CC-10
LP-CC-12
LP-CC-15
LP-CC-20
LP-CC-25
LP-CC-30
Features:
• 200kA interrupting rating complies with NEC
®
Section 110.9
for today's large capacity systems.
• Fast short-circuit protection and dual-element, time-delay
performance provide ultimate protection.
• Reduces existing fuse inventory by up to 33% when
upgrading to Low-Peak fuses.
• Consistent 2:1 ampacity ratios for all Low-Peak fuses make
selective coordination easy.
• Time-delay characteristic avoids unwanted fuse openings
from surge currents while fast response speed under short-
circuit conditions provides a high degree of current
limitation.
• Current-limitation protects downstream components against
damaging thermal and magnetic effects of short-circuit
currents.
• A superior, all-purpose, space-saving branch circuit fuse
that meets most protection requirements up to 30A.
• Very compact, with a physical size only
13
32
" x 1
1
2
"
(10.3 x 38.1mm) with rejction tip.
• Proper sizing can provide "no damage" Type 2 coordinated
protection for NEMA and IEC motor controllers.
• Can be used where either a time-delay or a fast-acting fuse
is needed, making selection easier and reducing spare fuse
inventories for substantial cost reduction.
• Superior protection for small horsepower motor circuits.
Recommended Fuse Blocks and Holders
Fuse Amps
0-30
1-Pole
2-Pole
Open Blocks
BC6031_
BC6032_
DIN-Rail Holders
CHCC1D_
CHCC2D_
Panel Mount Holders
HPS
HPF
In-Line Holders
HEX
HEZ
3-Pole
BC6033_
CHCC3D_
OPM-NG-_
OPM-1038_
OPM-1038_SW
Carton Quantity:
0-30
0-30
0-30
For additional information on the Class CC fuse blocks and
holders, see data sheets:
• Open Blocks # 1105 (BC Series)
• DIN-Rail Holders # 3185 (CHCC), # 1109 (OPM),
# 1102 (OPM-1038), 1103 (OPM-1038_SW),
• Panel Mount Holders # 2113 (HPS), # 2114 (HPF)
• In-Line Holders # 2126 (HEX), # 2130 (HEZ)
0813
BU-SB13XXX
Page 1 of 3
Data Sheet # 1023
What are isolated digital inputs?
Although isolated digital inputs and digital isolators sound similar, there are actually some significant differences between them. After reading this article, hopefully you will be able to easily tel...
qwqwqw2088 Analogue and Mixed Signal
Power supply design for next generation 48V distributed power architecture
In order to reduce the size of the power supply while retaining the compact brick model, power supply manufacturers must reduce the height of the brick module and ( or ) move the external power supply...
feifei Power technology
[Help] Communication problem between 430 SPI interface and 74HC595
I use 430169 SPI bus to connect to 74HC595, there are 4 595s in total, they are cascaded.Data is displayed statically. Data received from asynchronous serial port is sent to 595 through SPI port for d...
mdlv Microcontroller MCU
DDS (NCO) cordic based on coordinate shift transformation
The Verilog program of DDS written based on Cordic algorithm, with simulation program of Modelsim, is mainly written because I want to use CPLD to do DDS, but my CPLD resources are too few, only 570 L...
luowhu Analogue and Mixed Signal
ADI Utility Download Recommendations
[size=4][font=微软雅黑]Recommend[/font]some practical tools of ADI, if you need them, [url=https://adclick.g.doubleclick.net/pcs/click?xai=AKAOjssoGz65y6cXoPTTAZ-z-W4MU9jLiYZMp7Znm1dTBewfDE6yZKkmlwW1e78pu...
eric_wang ADI Reference Circuit
Design of impedance matching network for broadband antenna
Antennas are devices that transmit or receive electromagnetic waves. The quality of matching directly affects the antenna's standing wave ratio (SWR) and antenna efficiency, and even determines the su...
Jacktang RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 406  325  1586  429  2110  9  7  32  43  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号