8D0-25Z04BA022

Description
MIL Series Connector, 56 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size692KB,12 Pages
ManufacturerSOURIAU
Environmental Compliance  
Download Datasheet Parametric View All

8D0-25Z04BA022 Overview

MIL Series Connector, 56 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

8D0-25Z04BA022 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
MakerSOURIAU
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999, EMI SHIELDED, POLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Environmental characteristicsENVIRONMENT/FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceBLACK ZINC NICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size25
Termination typeCRIMP
Total number of contacts56
8D Series
D38999 Aluminum Series
Connector part numbers
Basic Series
8D
0
-
1
1
W
35
P
N
Shell style:
0:
Square flange receptacle
1:
In line receptacle
7:
Jam nut receptacle
5: Plug with RFI shielding
Also available:
.
Square flange receptacle with clinch nuts (see page 80)
.
Jam nut receptacle with double flange (see page 83)
Type:
None:
Connectors with standard crimp contacts.
L: Receptacle with long PC tail (male and female size #22D, #20).
C: Receptacle with short PC tail (male and female #22D, #20, #16).
S: Receptacle with specific PC tail (male et female #22D)
W: Receptacle with male contacts #22D for wire wrap (3 wraps)
T:
Receptacle with male contacts #20 for wire wrap (2 wraps)
P:
Receptacle with solder cup - only available for Reinforced sealing Series (see
page 75) - male and female size #22D; male #16 & #1
2; female #16 & #1
2
and male female #20 please consult us
Shell size: 09, 1 , 1 15, 1 1 21 23, 25
1 3,
7, 9, ,
Plating:
W:
Olive drab cadmium
F: Nickel
ZC:
Green zinc cobalt
Z: Black zinc nickel
Contact layout:
See pages 1 to 16
3
Contact type:
P:
Pin
A:
Connector supplied less pin contact or with specific contacts (connector marking: A + orientation)
S:
Socket
B:
Connector supplied less socket contact or with specific contacts (connector marking: B + orientation)
Orientation: N, A, B, C, D, E
(see page 64)
Specification:
046:
Tinned straight PC tail
251:
Connector provided with power contacts (layouts with contact #8)
022: Fuel tank
Special custom:
None:
Standard plastic cap
M:
Antistatic plastic cap
L: For P or S contact type only, connectors delivered without contacts, connectors marking P or S plus orientation
-
-
L
22
How to use and register ActiveX controls under EVC?
How can I use and register an ActiveX control in EVC? When I choose to insert an ActiveX control in EVC, the folder is empty. Thank you....
weipingid Embedded System
Some questions about SD card wiring
I don't know if anyone has experience in using ATmega16 with SD card. I would like to ask, can the SD card be directly connected to the ATmega16 pin? Do I need to connect any resistors, such as curren...
lg7412374123 Embedded System
American scientists invent artificial leaf solar cell
A group of researchers from the University of North Carolina in the United States recently announced a solar power generation device based on hydrogel technology - an artificial leaf. The researchers ...
lopopo Energy Infrastructure?
Why are components of different packages used in circuits?
In many circuits, there are many chips with different packages, some are 0805, some are 0603. Why don’t resistors use the same package? What’s the difference?...
dxn0622 PCB Design
Aluminum enterprise dedicated diesel generator and UPS test tools: Fuguang Electronics IAC-380 intelligent AC dummy load
1. The importance of backup power system to aluminum production In November this year, a transformer exploded in the production workshop of a large domestic aluminum group, causing hundreds of electro...
lily1987 Industrial Control Electronics
【C2000 usage experience】Don’t make C language statements too complicated
When performing PID operations, referring to the practices of others, it is like this: return (pp->Proportion * Error // proportional term +pp->Integral * pp->SumError // integral term +pp->Derivative...
dontium Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1020  2384  1102  1957  2507  21  48  23  40  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号